Electromagnetic Compatibility (EMC)

Conformance

Products displaying the CE mark are in conformity with European Community Council Directive of 15 Dec 2004 on the approximation of the laws of the Member States relating to electromagnetic compatibility, 2004/108/EC. It was manufactured in conformity with a national standard that implements a harmonized standard: EN 60974-10 Electromagnetic Compatibility (EMC) Product Standard for Arc Welding Equipment. It is for use with other Lincoln Electric equipment. It is designed for industrial and professional use.

Introduction

All electrical equipment generates small amounts of electromagnetic emission. Electrical emission may be transmitted through power lines or radiated through space, similar to a radio transmitter. When emissions are received by other equipment, electrical interference may result. Electrical emissions may affect many kinds of electrical equipment; other nearby welding equipment, radio and TV reception, numerical controlled machines, telephone systems, computers, etc. Be aware that interference may result and extra precautions may be required when a welding power source is used in a domestic establishment.

Installation and Use

The user is responsible for installing and using the welding equipment according to the manufacturer’s instructions. If electromagnetic disturbances are detected then it shall be the responsibility of the user of the welding equipment to resolve the situation with the technical assistance of the manufacturer. In some cases this remedial action may be as simple as earthing (grounding) the welding circuit, see Note. In other cases it could involve construction of an electromagnetic screen enclosing the power source and the work complete with associated input filters. In all cases electromagnetic disturbances must be reduced to the point where they are no longer troublesome.

Note: The welding circuit may or may not be earthed for safety reasons according to national codes. Changing the earthing arrangements should only be authorized by a person who is compe- tent to access whether the changes will increase the risk of injury, e.g., by allowing parallel welding current return paths which may damage the earth circuits of other equipment.

Assessment of Area

Before installing welding equipment the user shall make an assessment of potential electromagnetic prob- lems in the surrounding area. The following shall be taken into account:

a)other supply cables, control cables, signaling and telephone cables; above, below and adjacent to the welding equipment;

b)radio and television transmitters and receivers;

c)computer and other control equipment;

d)safety critical equipment, e.g., guarding of industrial equipment;

e)the health of the people around, e.g., the use of pacemakers and hearing aids;

f)equipment used for calibration or measurement

g)the immunity of other equipment in the environment. The user shall ensure that other equipment being used in the environment is compatible. This may require additional protection measures;

h)the time of day that welding or other activities are to be carried out.

Image 6
Contents Safety Depends on You LN-25PIPESafety California Proposition 65 Warnings Electric Shock can kill Welding and Cutting Sparks can Cause fire or explosion IiiPrécautions DE Sûreté Sûreté Pour Soudage a L’ArcSafety Methods of Reducing Emissions Mains Supply Vii Please Examine Carton and Equipment For Damage ImmediatelyOn-Line Product Registration TAbLE of Contents Installation Technical Specifications LN-25 Pipe K2614-10Wire SIzES High Frequency Protection Safety PrecautionsLocation Weld CAbLE SIzEFunction Pin Wiring CAbLE ConnectionsShielding GAS Connection Wire Drive Configuration Procedure to Install Drive Rolls and Wire GuidesChanging the GUN Receiver bUSHING GUN Connection Pressure ARM AdjustmentLoading Spools of Wire Fe, CrNiPower Source to LN-25 Pipe DescriptionCV-305 LN-25 PipeSafety Precautions OperationGeneral Description Wire Feed Speed KNOb Case Front Controls See Figure b.1Thermal LED, Motor Overload POWER-UP Sequence Wire Feed SPEED/AMPERAGE DisplaySET-UP Menu WFS CALIbRATION with Digital Meters Wire Feed Speed UnitsModel Run-in Wire Feed Speed RUN-INDisplay Hold Left Display SelectionAmperage CALIbRATION WFS KNOb RangeInternal Controls Figure b.2Cold Feed PUSHbUTTON Step Trigger Interlock SwitchInternal Controls Description Step TriggerRear Controls GAS Purge PUSHbUTTONAccessories Factory Installed EquipmentDrive Roll Kits See Parts Pages Accessories K1500-5 Gun Receiver Bushing compatible Maintenance Routine MaintenancePeriodic Maintenance TROUbLESHOOTING Electric Shock can killPOSSIbLE PRObLEMSSymptoms Cause Recommended Course of ActionOutput Problems TROUbLESHOOTING Diagrams LN-25 PipeDimension Print Precaucion Warnung