Lincoln Electric IM10092 manual Wire Feed Speed Units, WFS CALIbRATION with Digital Meters, Run-In

Page 21

b-5

OPERATION

b-5

 

 

 

WIRE FEED SPEED UNITS

To change the wire feed speed units:

Rotate the WFS knob to the left to use “inches/minute” for the wire feed speed units.

US

O O A

V

LN-25™ PIPE, CCC

O O WFS

WFS CALIbRATION WITH DIGITAL METERS

To calibrate the wire feed speed, before entering the set-up menu. When first entering WFS Calibration, the calibration factor displayed is based upon the position of the knob and does not reflect the actual calibration factor stored in memory.

Rotate the WFS knob to the right to use “meters/minute” for the wire feed speed units.

Then rotate the WFS knob to the 12 o’clock position.

EU ro

O O A

V

LN-25™ PIPE, CCC

O O WFS

Set the display to the desired wire feed speed (example: 400 inches per minute)

Measure the actual wire feed speed (example: 405 inches per minute)

While in the set-up menu, adjust the calibration factor as follows:

Press the set-up button again to enter the Run-In menu.

RUN-IN

“Run-in” refers to the wire feed speed during the time from when the trigger is pulled to when an arc is struck.

When Run-in is “ON”, the wire feed speed is reduced until an arc is struck. Factory setting is Run-In “OFF”.

Model

Run-in Wire Feed Speed

LN-25™ PIPE

50 in/min

Actual WFS =Calibration Factor

Example 405

=1.01

Set WFS

400

 

Press the set-up button.

When Run-in is “OFF”, the wire feed speed is the same as the welding wire feed speed. Turn Run-In “OFF” for fast, crisp starts, especially when running with .035 or .045 (0.9 or 1.2mm) solid steel wires at high wire feed speeds.

To change the Run-in setting:

Rotate the WFS knob to the left to turn Run-In OFF.

r un OFF

O O A

V

LN-25™ PIPE, CCC

O O WFS

Rotate the WFS knob to the right to turn Run-In ON.

Then rotate the WFS knob to the 12 o’clock position.

runOn

O O A

V

LN-25™ PIPE, CCC

O O WFS

Press the set-up button again to enter the WFS cali- bration menu.

LN-25™ PIPE

Image 21
Contents LN-25PIPE Safety Depends on YouCalifornia Proposition 65 Warnings SafetyElectric Shock can kill Iii Welding and Cutting Sparks can Cause fire or explosionSûreté Pour Soudage a L’Arc Précautions DE SûretéSafety Methods of Reducing Emissions Mains Supply Vii Please Examine Carton and Equipment For Damage ImmediatelyOn-Line Product Registration TAbLE of Contents Installation Technical Specifications LN-25 Pipe K2614-10Wire SIzES Location Safety PrecautionsHigh Frequency Protection Weld CAbLE SIzEFunction Pin Wiring CAbLE ConnectionsShielding GAS Connection Wire Drive Configuration Procedure to Install Drive Rolls and Wire GuidesChanging the GUN Receiver bUSHING Loading Spools of Wire Pressure ARM AdjustmentGUN Connection Fe, CrNiDescription Power Source to LN-25 PipeLN-25 Pipe CV-305Operation Safety Precautions General Description Wire Feed Speed KNOb Case Front Controls See Figure b.1Thermal LED, Motor Overload POWER-UP Sequence Wire Feed SPEED/AMPERAGE DisplaySET-UP Menu Model Run-in Wire Feed Speed Wire Feed Speed UnitsWFS CALIbRATION with Digital Meters RUN-INAmperage CALIbRATION Left Display SelectionDisplay Hold WFS KNOb RangeFigure b.2 Internal ControlsInternal Controls Description Step Trigger Interlock SwitchCold Feed PUSHbUTTON Step TriggerGAS Purge PUSHbUTTON Rear ControlsAccessories Factory Installed EquipmentDrive Roll Kits See Parts Pages Accessories K1500-5 Gun Receiver Bushing compatible Maintenance Routine MaintenancePeriodic Maintenance Electric Shock can kill TROUbLESHOOTINGSymptoms PRObLEMSPOSSIbLE Cause Recommended Course of ActionOutput Problems TROUbLESHOOTING LN-25 Pipe DiagramsDimension Print Precaucion Warnung