| TROubLEShOOTING |
| |||
|
|
|
|
|
|
| Observe all Safety Guidelines detailed throughout this manual | ||||
|
|
|
|
|
|
| PRObLEMS |
| POSSIbLE |
| RECOMMENDED |
| (SYMPTOMS) |
| CAuSE |
| COuRSE OF ACTION |
|
|
|
|
| |
|
| Digital Display Models Error Codes |
|
| |
Err 81 | Motor overload, long term. | 1. | Check that the electrode slides | ||
|
|
|
|
| easily through the gun and cable. |
|
|
|
| 2. | Remove tight bends from the gun |
|
|
|
|
| and cable. |
|
|
|
| 3. | Check that the spindle brake is |
|
|
|
|
| not too tight. |
|
|
|
| 4. | Verify a high quality electrode is |
|
|
|
|
| being used. |
|
|
|
| 5. | Wait for the error to reset and the |
|
|
|
|
| motor to cool (approximately 1 |
|
|
|
|
| minute). |
|
|
|
| ||
Err 82 | Motor overload, short term. | 1. | Check that motor can turn freely | ||
|
|
|
|
| when idle arm is open. |
|
|
|
| 2. | Verify that the gears are free of |
|
|
|
|
| debris and dirt. |
|
|
|
|
|
|
|
|
| Output Problems |
|
|
The feeder does power up - no dis- | 1. | The work sense lead is discon- | 1. | Connect the work sense lead to | |
play, no cold feed. |
| nected or is a poor electrical con- |
| the work in a location free of dirt, | |
|
|
| nection. (Across the arc models) |
| rust and paint. |
|
| 2. | The power source is OFF. | 2. | Turn ON the power source. |
|
| 3. | The circuit breaker for the wire | 3. | Reset the circuit breakers. |
|
|
| feeder on power source have |
|
|
|
|
| tripped. (control cable models) |
|
|
|
| 4. | The control cable may be loose or | 4. | Tighten, repair or replace the con- |
|
|
| damaged. (control cable models) |
| trol cable. |
|
|
|
|
| |
(Across the Arc models) | 1. | The contactor coil connections are | 1. | Verify the contactor coil connec- | |
The wire feeder power up but there |
| loose. |
| tions. | |
is no output when the trigger is | 2. | The contactor has failed. | 2. | Replace the contactor. | |
pulled. The shielding gas is flowing |
|
|
|
| |
and the drive rolls turn. |
|
|
|
| |
|
|
|
|
| |
No shielding gas. | 1. | The gas supply is OFF or empty. | 1. | Verify the gas supply is ON and | |
|
|
|
|
| flowing. |
|
| 2. | The gas hose is cut or crushed. | 2. | Route the gas hose so it avoids |
|
|
|
|
| sharp corners and make sure |
|
|
|
|
| nothing is on top of it. Repair or |
|
|
|
|
| replace damaged hoses. |
|
| 3. | The flow meter valve is closed. | 3. | Open the flow meter valve. |
|
| 4. | Dirt or debris is in the solenoid. | 4. | Apply filtered shop at 80psi to the |
|
|
|
|
| solenoid to remove dirt. |
|
| 5. | There is a loose solenoid connec- | 5. | Remove the cover and check that |
|
|
| tion. |
| all connections are in good condi- |
|
|
|
|
| tion. |
|
| 6. | The solenoid has failed. | 6. | Replace solenoid. |
|
|
|
|
|
|
CAuTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Authorized Field Service Facility for technical troubleshooting assistance before you proceed.