Digital Display Models Error Codes

 

 

Err 81

Motor overload, long term.

1.

Check that the electrode slides

 

 

 

 

 

easily through the gun and cable.

 

 

 

 

2.

Remove tight bends from the gun

 

 

 

 

 

and cable.

 

 

 

 

3.

Check that the spindle brake is

 

 

 

 

 

not too tight.

 

 

 

 

4.

Verify a high quality electrode is

 

 

 

 

 

being used.

 

 

 

 

5.

Wait for the error to reset and the

 

 

 

 

 

motor to cool (approximately 1

 

 

 

 

 

minute).

 

 

 

 

Err 82

Motor overload, short term.

1.

Check that motor can turn freely

 

 

 

 

 

when idle arm is open.

 

 

 

 

2.

Verify that the gears are free of

 

 

 

 

 

debris and dirt.

 

 

 

 

 

 

 

 

 

Output Problems

 

 

The feeder does power up - no dis-

1.

The work sense lead is discon-

1.

Connect the work sense lead to

play, no cold feed.

 

nected or is a poor electrical con-

 

the work in a location free of dirt,

 

 

 

nection. (Across the arc models)

 

rust and paint.

 

 

2.

The power source is OFF.

2.

Turn ON the power source.

 

 

3.

The circuit breaker for the wire

3.

Reset the circuit breakers.

 

 

 

feeder on power source have

 

 

 

 

 

tripped. (control cable models)

 

 

 

 

4.

The control cable may be loose or

4.

Tighten, repair or replace the con-

 

 

 

damaged. (control cable models)

 

trol cable.

 

 

 

 

 

(Across the Arc models)

1.

The contactor coil connections are

1.

Verify the contactor coil connec-

The wire feeder power up but there

 

loose.

 

tions.

is no output when the trigger is

2.

The contactor has failed.

2.

Replace the contactor.

pulled. The shielding gas is flowing

 

 

 

 

and the drive rolls turn.

 

 

 

 

 

 

 

 

 

No shielding gas.

1.

The gas supply is OFF or empty.

1.

Verify the gas supply is ON and

 

 

 

 

 

flowing.

 

 

2.

The gas hose is cut or crushed.

2.

Route the gas hose so it avoids

 

 

 

 

 

sharp corners and make sure

 

 

 

 

 

nothing is on top of it. Repair or

 

 

 

 

 

replace damaged hoses.

 

 

3.

The flow meter valve is closed.

3.

Open the flow meter valve.

 

 

4.

Dirt or debris is in the solenoid.

4.

Apply filtered shop at 80psi to the

 

 

 

 

 

solenoid to remove dirt.

 

 

5.

There is a loose solenoid connec-

5.

Remove the cover and check that

 

 

 

tion.

 

all connections are in good condi-

 

 

 

 

 

tion.

 

 

6.

The solenoid has failed.

6.

Replace solenoid.

 

 

 

 

 

 

CAuTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

RED-D-ARC LN-25™ PRO EXTREME

Image 29
Contents RED-D-ARC California Proposition 65 Warnings SafetyElectric Shock can kill Welding and Cutting Sparks can Cause fire or explosion PRÉCAuTIONS DE Sûreté Electromagnetic Compatibility EMC Methods of Reducing Emissions Mains Supply Vii Thank YouTAbLE of Contents Gearing Wire Feed InstallationHIGh FREQuENCY Protection Safety PRECAuTIONSWeld CAbLE SIzE Electrode LeadGuN buShING, ThuMb Screw and Socket hEAD CAP Screw ShIELDING GAS ConnectionLoading Spools of Wire PROCEDuRE to Install Drive Rolls and Wire GuIDESGuN Connection PRESSuRE ARM and ADJuSTMENTFIGuRE A.6 Across ThE ARC SET-uPSFIGuRE A.8 Operation OFF Wire FeederVoltage ProtectiveDefinition of Welding Terms Recommended Power SOuRCESRecommended Processes Process LimitationsCase Front Controls See Figure b.1 Wire Feed Speed KNObDigital Display WFSSET-uP PuShbuTTON Trigger ConnectorWork Sense Lead Internal Controls Spool Retainer Optional Timer KITInternal Controls Description GAS PuRGE PuShbuTTON Rear ControlsDrive Roll Kits uSED AccessoriesFactory Installed EQuIPMENT Accessories With Oxo guns ROuTINE Maintenance MaintenancePeriodic Maintenance CALIbRATION SpecificationElectric ShOCK can kill TROubLEShOOTINGSymptoms PRObLEMS POSSIbLERecommended CAuSE COuRSE of ActionPOSSIbLE CAuSE PRObLEMSTROubLEShOOTING Diagrams 17.19 Dimension PrintRED-D-ARC LN-25 PRO Extreme RED-D-ARC LN-25 PRO Extreme Atenção Atenção