| OPERATION |
| |||||
|
|
|
|
|
|
|
|
|
|
|
| TABLE B.4 (Continued) | SET UP MENU PARAMETERS |
| |
|
|
|
|
|
|
| |
|
| Parameter | Selection/ | Parameter | Description |
| |
|
| Symbol | * Default Value | Number |
|
| |
|
|
|
|
|
|
|
|
|
|
|
| Display Off |
|
|
|
|
|
|
| Display in 7 Segment LED | 751 | Output Current Displayed |
|
|
|
|
| Display* |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Display Off* |
|
|
|
|
|
|
| Display in 7 Segment LED | 752 | Output Voltage Displayed |
|
|
|
|
| Display |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Display Off* |
|
|
|
|
|
|
| Display in 7 Segment LED | 753 | Input Phase Displayed |
|
|
|
|
| Display |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Display Off* |
|
|
|
|
|
|
| Display in 7 Segment LED | 754 | Input Voltage Displayed |
|
|
|
|
| Display |
|
|
|
This function sets the initial start energy limit. Set this number to a higher setting than the factory default if needed to improve starting of large diameter tungsten electrodes.
0.5to 1.0 manual start energy setting.
1.2to 5.0 = max. Incrementing limit.
(See Note) | 104 | AC TIG Start Power (for AC TIG only) |
Note: The machine will try to start the arc at a start power of 1. If the arc does not establish it will incrementally increase the start power and try to restrike up to the set limit.
OPTIONAL COOL-ARC 35 WATER COOLER
The optional
When the Invertec®
IMPORTANT: If the
In this case the cooler can be turned to the “off mode” by depressing and holding the push button on the cooler until the cooler’s display reads “oo”. To turn the cooler back on you can depress and hold the