Lincoln Electric IM10051 manual Optional Accessories, Compatible Equipment, Field Installed

Page 27

C-1

ACCESSORIES

C-1

 

 

 

OPTIONAL ACCESSORIES

AND COMPATIBLE EQUIPMENT

Field Installed

K857 - Remote Output Control - For Stick welding. Portable current control provides the same range as the current control on the welder. Consists of a 6-pin connector which plugs into the remote control connec- tor. 25 foot cable length.

K870 - Foot Amptroltm for TIG welding. The foot Amptrol energizes the output and controls the output remotely. The Foot Amptrol connects directly to the 6- pin remote control connector.

K963-3 - Hand Amptroltm for TIG welding. The hand Amptrol energizes the output and controls the output remotely. The Hand Amptrol connects directly to the 6-pin remote control connector.

K814 - Arc Start Switch - Energizes the output for TIG welding if remote output control of the amperage is not desired. It allows on/off TIG welding at the amperage set by the Current Control on the control panel. When using the Arc Start Switch set the Output Control to the “LOCAL” position.

K2630-1 - Cool-Arc® 35 Water Cooler- Attaches underneath the Invertec® V311-T AC/DC and electri- cally connects to the Invertec® V311-T AC/DC. This smart cooler varies its speed based on coolant tem- perature and monitors coolant pressure.

K2694-1 Inverter Cart- Conveniently holds the Cool- Arc 35 and Invertec® V311-T AC/DC power source. Features a tool storage tray for convenience and a cylinder platform to hold a gas bottle

TIG TORCH STARTER KITS

K2266-1TIG-Mate 17 Air Cooled TIG Torch Starter Pack. One complete easy-to-order kit pack- aged in its own portable carrying case. Includes: PTA- 17 torch, parts kit, Harris flowmeter/regulator, 10 ft. gas hose, Twist-Mate™ adapter, work clamp and cable.

K2267-1TIG-Mate 20 Water-Cooled TIG Torch Starter Pack. One complete easy-to-order kit pack- aged in its own portable carrying case. Includes: PTW-20 torch, parts kit, Harris flowmeter/regulator, 10 ft. gas hose, Twist-Mate™ adapter, work clamp and cable, and 10 ft. water hose.

Magnum® TIG Torches – The following standard Magnum® TIG torches may be used with the Invertec® V311-T AC/DC for Lincoln’s full line of TIG torches including flex head models consult publication E12.150.

K1781-1 PTA-9 12.5 ft.(3.8m) Air-Cooled 125A

K1781-3 PTA-9 25 ft.(7.6m) Air-Cooled 125A

K1782-1 PTA-17 12.5 ft.(3.8m) Air-Cooled 150A

K1782-3 PTA-17 25 ft.(7.6m) Air-Cooled 150A

K1783-1 PTA-26 12.5 ft.(3.8m) Air-Cooled 200A

K1783-3 PTA-26 25 ft.(7.6m) Air-Cooled 200A

K1784-3 PTW-20 12.5 ft.(3.8m) Water-Cooled 250A

K1784-4 PTW-20 25 ft.(7.6m) Water-Cooled 250A

K1784-1 PTW-18 12.5 ft.(3.8m) Water-Cooled 350A

K1784-2 PTW-18 25 ft.(7.6m) Water-Cooled 350A

NOTE: Each torch requires a Twist-Mate™ adapter, collets, collet bodies, and nozzles and are not includ- ed and must be ordered separately.

INVERTEC® V311-T AC/DC TIG

Image 27
Contents 11685 InvertecCalifornia Proposition 65 Warnings SafetyElectric Shock can kill Iii Welding and Cutting Sparks can Cause fire or explosionSûreté Pour Soudage a L’Arc Précautions DE SûretéElectromagnetic Compatibility EMC Safety Vii Please Examine Carton and Equipment For Damage ImmediatelyOn-Line Product Registration Table of Contents Invertec V311-T AC/DC TIG InstallationTechnical Specifications Invertec V311-T AC/DC TIG K2915-1 Operating Temperature Range Storage Temperature RangeTilting Safety PrecautionsSelect Suitable Location StackingInput Connections Reconnect ProcedureThree Phase Input Input Plug InstallationPower Cord Connection Single Phase InputOutput Connection for Stick Welding Figure A.2 Output ConnectionsOutput and GAS Connection for TIG Welding Figure A.1 Work Cable ConnectionShielding GAS Connection Remote Control ConnectionWelding Capability Safety InstructionsOperation General DescriptionLower Control Panel Figure B.2 Rear Control Panel Figure B.1Seven segment LED display H Push BUTTON/ROTARY Encoder Mode Push Buttons A-DUser Interface Overview and Operation Dynamic LCD Display Status LED LightsDynamic LCD Display TIG Trigger Modes Two Step with Arc Start SwitchWelding Modes Table B.2Recalling from Memory Stick Trigger ModesTIG Pulse Modes Saving to MemoryParameter Range Symbol Unit Min MaxWelding Parameters Table B.3 ParameterFigure B.7 User Menu SET UP ParametersVRD Table B.4 SET UP Menu ParametersOptional COOL-ARC 35 Water Cooler Table B.4Tips for Improved TIG Starting Stick Crisp Mode Dynamic Current RegulationCompatible Equipment AccessoriesOptional Accessories Field InstalledCable Plugs Routine Maintenance MaintenanceSafety Precautions Input Filter Capacitor Discharge ProcedureHOW to USE Troubleshooting Guide TroubleshootingTroubleshooting Problems in TIG Welding Field Service FacilityYour local Lincoln Authorized Electrical Failures Exx 5TROUBLESHOOTINGE-5Alarm ID Codes Alarm Icon + Alarm Code + Alarm Type IconWiring Diagram Wiring DiagramsPrecaucion Warnung