Lincoln Electric IM10006 User Responsibility, Design Features Advantages, Cutting Capability

Page 12

B-2

OPERATION

B-2

USER RESPONSIBILITY

Variation such as plate chemistry, plate surface condi- tion (oil, scale), plate thickness, preheat, quench, gas type, gas flow rate and equipment may produce results different than those expected. Some adjust- ments to procedures may be necessary to compen- sate for unique individual conditions. Test all proce- dures duplicating actual field conditions.

DESIGN FEATURES AND

ADVANTAGES

Light weight

Continuous output control

Indicator LEDs

Cooling fan

Rapid arc restrike for cutting across gaps

3 second arc delay for safety

Adjustable air pressure regulator with locking feature

Part-in-place verification for safety and proper operation

Thermostatic protection with thermal indication

Air inlet filter with water purge button to protect air path and torch

Lighted ON/OFF switch

High input voltage protection

CUTTING CAPABILITY

The PLASMA 20 is rated for 20A @ 40% duty cycle. The unit is designed to cut up to 3/8” inch mild steel, but has the capability to cut other metals such as stainless and aluminum (travel speed will vary).

TORCH CONSUMABLES

The torch consumables consist of an Electrode, Gas Distributor Ring, Nozzle, and Shield Cup. The con- sumable parts must be placed in the correct order and secured properly for the unit to operate.

LIMITATIONS

For indoor use only.

Do not exceed output current and duty cycle rating of machine. Do not use the PLASMA 20 for pipe thawing.

Do not power with generators or engine drives.

CONTROLS AND SETTINGS

5

4

6

3

 

8

2

7

 

 

 

1

10

9

1.ON/OFF Switch In the ON position the machine is ready for normal operation. All system control circuits are activated. OFF position deactivates control circuits.

2.Output Current Knob-Adjusts the cutting current supplied by the machine according to the thick- ness of material/speed.

3.Green LED – Turns ON when input voltage is applied within normal range – blinks slowly when input voltage goes above 130Vac, or below 95Vac.

4.Red LED – Turns ON when torch is triggered Blinks quickly during 3 second safety pre-flow prior to pilot arc ignition Blinks slowly if cutting arc is not initiated after 3 second pilot arc ignition.

5.Yellow LED – Turns ON when the thermal protec- tion is activated. Blinks slowly when the under pressure protection is working (the pressure is under 55 PSI, 3.8 Bar)

6.Air Regulator – Adjusts the input air pressure – pull upward to unlock, press down to lock – nomi- nal air pressure setting is 65 PSI, 4.5 Bar.

Note: Regulator should never be set above 87 PSI (6 Bar).

7.Compressed Air Connection

8.Input Cord

9.Work cable with clamp

10.Torch

PLASMA 20

Image 12
Contents Plasma Safety Plasma Cutting or Gouging can be hazardousCylinder may explode if damaged Electric and Magnetic FieldsPage Précautions DE Sûreté Sûreté Pour Soudage a L’ArcThank You Table of Contents Installation Technical Specifications PlasmaVoltage Circuit BreakerSafety Precautions Electric Shock can Kill Select Proper LocationStacking TiltingCompressed AIR or GAS Input Connection Connection to Ground CableTorch Connection Safety Precautions OperationDescription Design Features Advantages Controls and SettingsUser Responsibility Cutting CapabilityCutting Operations Checking AIR QualityCutting with a Hand Torch Torch AT 30 0 Angle Operating Faults Pilot ARC DiscussionTorch Consumable Parts Selection Maintenance Routine MaintenancePeriodic Maintenance Do not use solvents to clean the filter use soapy water only Compressed AIR FilterTroubleshooting HOW to USE Troubleshooting GuideYour local Authorized Field Service Facility Green LED ON, YellowDiagrams Plasma Precaucion Warnung