Section 6

5.2 42 VAC INPUT POWER CONNECTIONS

Your Wire Feeder comes factory ready with a harness to plug directly into all 14 pin

Lincoln Power Sources equipped with 42 VAC auxiliary.

The 42 VAC is connected to the PC Board on terminal strip J5 #1 (neutral) and #2

(hot) and Ground to the Cabinet chassis.

5.3 POSA START CONNECTIONS

Posa Start circuitry aids welding starts by sensing arc establish signals. A weld ground signal is required for this to circuit to work, which is provided through the Power Harness to the Power Source and is internally connected to the P.C. board on terminal strip J6 terminal 2.

Note: Place polarity switch to DCEP. Refer to scetion 7.3 for power supply settings to insure proper Posa Start operation.

WARNING: TURN THE INPUT POWER TO THE POWER SOURCE OFF AT THE DISCONNECT SWITCH BEFORE PERFORMING ANY WORK.

WIRE THREADING PROCEDURE

6.1 WIRE SPOOL INSTALLATION

Release latches, and open right side door of cabinet.

Remove spool retainer from spindle hub.

Install wire spool onto spindle hub so that wire feeds from bottom of spool towards slave motor. Make sure that the hole in the spool aligns with pin on spindle hub. The white dot on the end of the spindle hub will aid in this alignment.

Replace the spool retainer.

6.2 THREADING PROCEDURE

Place wire size selector switch on front panel to the correct position for the wire being used.

Loosen end of wire from spool and cut off any kinked or bent portions.

Unreel and straighten out first 6" to 8" of wire.

Release tension from slave motor drive rolls.

Route wire into inlet guide, along drive roll groove, and into wire conduit.

Prevent the wire spool from turning with the palm of the right hand, and at the same time grasp the slave motor pressure adjusting knob.

Pull the torch trigger and slowly tighten the slave motor pressure adjusting knob until the slave motor stalls.

CAUTION:

EXCESSIVE DRIVE ROLL TENSION WILL REDUCE RATHER

THAN IMPROVE WIRE FEED PERFORMANCE.

K1587-1 Cobramatic® Owner's Manual - Page 11

Image 11
Contents Wire Feeder Page Page Page Page Page This page Intentionally Blank Table of Contents This page Intentionally Blank Location SpecificationsPosa Start Connections 42 VAC Input Power ConnectionsWire Spool Installation Threading ProcedureFeeder Controls PRE-SETTING Slave Motor TensionWire Guard GeneralPosa Start Controls CV/CC Posa Start Operating ProcedureCC Posa Start Operation Testing the TorchRelay K2 Operation Testing the Input Power CircuitsTesting the Speed Control Main P.C. Board Connections Troubleshooting Exploded View K1587-1 Wire Feed Cabinet Parts List K1587-1 Wire Feed Cabinet Exploded View MK P/N 003-2016 Front Panel Exploded View MK P/N 003-0570 Spindle Brake Assy Exploded View MK P/N 001-1232 Slave Motor Assy Wire Harness for Input Power from Power Source Main P.C. Board Parts Placement Main P.C. Board Parts ListFront Panel Circuit Board Cobramatic Wiring Schematic Cobramatic Torch Connections Cobramatic Block Diagram California AlabamaArizona ArkansasIndiana IdahoLouisiana IllinoisSouth Carolina OhioOklahoma PennsylvaniaCanada WisconsinPage Page This page Intentionally Blank Effective April 1