Lincoln Electric IM490-C manual Technical Specifications Invertec V250-S K1437-2

Page 9

 

A-2

 

 

 

 

 

 

 

 

 

 

 

 

 

INSTALLATION

 

 

 

 

 

 

 

 

 

 

A-2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Technical Specifications - Invertec V250-S - K1437-2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INPUT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

THREE PHASE

 

 

 

 

 

 

SINGLE PHASE

 

 

 

 

 

 

 

Standard

 

 

 

 

 

 

Input Current

 

 

 

 

Standard

 

 

Input Current

 

 

 

 

 

 

 

 

Voltage

 

 

 

 

 

at Rated Output

 

Model

 

 

Voltage

 

 

at Rated Output

Model

 

 

 

 

220/440 35% Duty Cycle

 

 

 

34/17

 

50/60 Hz

 

 

220/440 35% Duty Cycle

 

57/29

 

50/60 Hz

 

 

 

 

400 60% Duty Cycle

 

 

 

16

 

50/60 Hz

 

 

400 60% Duty Cycle

 

27

 

50/60 Hz

 

 

 

 

220/400/440 100% Duty Cycle

 

19/11/9

 

50/60 Hz

 

 

220/400/440 100% Duty Cycle

 

34/21/17

 

50/60 Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RATED

 

 

OUTPUT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

THREE PHASE

 

 

 

 

 

 

SINGLE PHASE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Volts at

 

 

 

 

 

 

 

 

 

 

 

Volts at

 

 

 

 

 

 

 

 

Duty Cycle(1)

 

 

Amps

 

 

Rated Amps

 

Model

 

 

Duty Cycle(1)

 

Amps

Rated Amps

 

Model

 

 

 

 

35% Duty Cycle(3)

 

250

 

 

 

 

 

30V

 

50/60Hz

 

 

35% Duty Cycle(3)

 

230

 

 

29V

 

50/60Hz

 

 

 

 

60% Duty Cycle

 

200

 

 

 

 

 

28V

 

50/60Hz

 

 

60% Duty Cycle

 

190

 

27.6V

 

50/60Hz

 

 

 

 

100% Duty Cycle

 

155

 

 

 

 

26.2V

 

50/60Hz

 

 

100% Duty Cycle

 

155

 

26.2V

 

50/60Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUTPUT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

THREE PHASE

 

 

 

 

 

 

SINGLE PHASE

 

 

 

 

 

 

 

Welding

 

 

 

 

 

 

 

 

 

 

Constant Open

 

Welding

 

 

 

 

Constant Open

 

 

 

 

Current Range

 

 

 

 

 

 

 

 

Circuit Voltage

 

Current Range

 

 

 

 

Circuit Voltage

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RECOMMENDED INPUT WIRE AND FUSE SIZES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

THREE PHASE

 

 

 

 

 

 

SINGLE PHASE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Type 75°C

 

 

 

 

 

 

 

 

 

 

 

 

Type 75°C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Type 75°C

 

Copper

 

 

 

 

 

 

 

 

 

 

 

Type 75°C

Copper

 

 

 

 

 

 

 

Fuse

 

 

Input

 

Copper

 

Ground

 

 

 

 

Fuse

 

Input

 

 

Copper

Ground

 

 

 

 

 

 

(Superlag)

Ampere

 

Wire in

 

Wire in

 

 

 

(Superlag)

Ampere

 

 

Wire in

Wire in

 

 

 

 

Input

 

or

 

 

Rating

 

Conduit

 

Conduit

 

 

Input

 

or

 

Rating

 

 

Conduit

Conduit

 

 

 

 

Voltage

 

Breaker

 

on

 

AWG (IEC)

 

AWG (IEC)

 

 

Voltage

 

Breaker

 

on

 

 

AWG (IEC)

AWG (IEC)

 

 

 

 

Frequency(2)

 

Size

 

 

Nameplate

 

Sizes

 

Sizes

 

 

Frequency(2)

 

Size

 

Nameplate

Sizes

Sizes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

208/60

 

50

 

 

 

 

34

 

 

10 (6mm2)

 

10 (6mm2)

 

 

208/60(3)

 

80

 

 

59

 

 

8 (8.4mm2)

10 (6mm2)

 

 

 

 

230/60

 

50

 

 

 

 

32

 

 

10(6mm2)

 

10 (6mm2)

 

 

230/60(3)

 

80

 

 

57

 

 

8 (8.4mm2)

10 (6mm2)

 

 

 

 

460/60

 

30

 

 

 

 

16

 

 

10 (6mm2)

 

10 (6mm2)

 

 

460/60

 

40

 

 

29

 

 

10 (6mm2)

10 (6mm2)

 

 

 

 

200/50/60

 

50

 

 

 

 

35

 

 

10 (6mm2)

 

10 (6mm2)

 

 

200/50/60

 

80

 

 

58

 

 

8 (8.4mm2)

10 (6mm2)

 

 

 

 

220/50/60

 

50

 

 

 

 

33

 

 

10 (6mm2)

 

10 (6mm2)

 

 

220/50/60

 

80

 

 

58

 

 

8 (8.4mm2)

10 (6mm2)

 

 

 

 

400/50/60

 

20

 

 

 

 

18

 

 

12 (4mm2)

 

12 (4mm2)

 

 

400/50/60

 

40

 

 

30

 

 

10 (6mm2)

10 (6mm2)

 

 

 

 

440/50/60

 

20

 

 

 

 

17

 

 

12 (4mm2)

 

12 (4mm2)

 

 

440/50/60

 

40

 

 

30

 

 

10 (6mm2)

10 (6mm2)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PHYSICAL DIMENSIONS

Height

Width

Depth

Weight

15.0 in.

9.1 in.

19.7 in.

41 lbs.

381 mm

231 mm

500 mm

19 Kg

 

 

 

 

(1)Based on a 10 min. period.

(2)Input voltage must be within ±10% of rated value.

(3)Excluding 400V-VAC Input

INVERTEC V250-S

Image 9
Contents INVERTECV250-SFebruary California Proposition 65 Warnings SafetyElectric Shock can kill Cylinder may explode if damaged Sûreté Pour Soudage a L’Arc Précautions DE SûretéInvertec V250-S Thank YouTable of Contents Installation Three Phase Single PhaseThree Phase Technical Specifications Invertec V250-S K1437-2 Safety Precautions Select Suitable LocationInput Connections Input Voltage Reconnect Procedure Input Fuse and Supply WirePower Input Connection for 50/60 HZ Machines Output Connections Remote Control ReceptacleQuick Disconnect Plugs Output CablesSafety Instructions OperationGeneral Description Figure B.1 Case Front Controls Controls and SettingsManual ARC Welding Stick Constant Current ProcessesAIR Carbon ARC Cutting TIG WeldingParallel Operation Overload ProtectionThermal Protection Options / Accessories AccessoriesRemote Controls Cable PlugsInput Filter Capacitor Discharge Procedure MaintenanceFilter Capacitor Conditioning Routine MaintenanceFigure D.2 Location of Maintenance Components PC Board Troubleshooting Procedures Troubleshooting & RepairPossible Areas SymptomsTroubleshooting & Repair Troubleshooting & Repair See Installation Section of this Troubleshooting & Repair Welding Problems Wiring DIAGRAM- Codes 10102 DiagramsWiring Diagram Invertec V250-S Electrical Diagrams Wiring DIAGRAM- Code Electrical DiagramsDimension Print Invertec V250-S Basic Course How To Read Shop DrawingsPrecaucion Warnung