Friedrich MW09Y3H, MW12Y3H manual To Select Mode Operation Press the START/STOP button b-9

Page 7

OPERATION

To Select Mode Operation

1

Press the START/STOP button (Fig.6 b-9).

The indoor unit’s OPERATION Indicator Lamp (green) (Fig. 3 a-5) will light.

 

The air conditioner will start operating.

2

Press the MODE button (Fig.6 b-2) to select the desired

mode.

Each time the button is pressed, the mode will change in the following order.

 

sAUTO

 

s COOL

s DRY

 

 

 

 

 

 

 

 

HEAT t

 

FAN t

 

 

 

 

 

About three seconds later, the entire display will reappear.

To Set the Thermostat

Press the SET TEMP. button (Fig. 6 b-4).

button: Press to raise the thermostat setting. button: Press to lower the thermostat setting.

Thermostat setting range:

AUTO

64-88 °F

Heating

60-88 °F

Cooling/Dry

64-88 °F

The thermostat cannot be used to set room temperature during the FAN mode (the temperature will not appear on the Remote Control Unit’s Display).

About three seconds later, the entire display will reappear.

The thermostat setting should be considered a standard value, and may differ somewhat from the actual room temperature.

Example: When set to COOL.

Example: When set to 80°F.

To Set the Fan Speed

Press the FAN button (Fig. 6 b-8).

Each time the button is pressed, the fan speed changes in the following order:

sAUTO

s HIGH

s MED

sLOW

sQUIET

About three seconds later, the entire display will reappear.

When set to AUTO:

 

Heating:

Fan operates so as to optimally circulate warmed air.

 

 

 

However, the fan will operate at very low speed when the temperature

 

 

 

of the air issued from the indoor unit is low.

 

Cooling :

As the room temperature approaches that of the thermostat setting,

 

 

 

the fan speed becomes slower.

 

Fan

:

The fan runs at the low fan speed.

Example: When set to AUTO.

 

 

 

The fan will operate at a very low setting during Monitor operation and at the start of the Heating mode.

En-6

Image 7
Contents Español Français English Mode D’EMPLOISafety Precautions ContentsMaintenance Features and FunctionsSleep Timer Coil DRY MIN. Heat A-9 a-1 10 a 11 a Name of PartsAir Filter Coil DRY Indicator Lamp yellowIntake Grille Fig Front PanelPreparation To Set the Thermostat Press the SET TEMP. button b-4 To Select Mode Operation Press the START/STOP button b-9Operation ModeTo Stop Operation Press the START/STOP button b-9 About Mode OperationAbout Auto Changeover Operation Timer Operation During Heating operation Sleep Timer OperationTo Change the Timer Settings About the Sleep TimerTypes of Air flow Direction Setting Adjusting the Direction of AIR CirculationVertical Air Direction Adjustment Press the SET button b-11 Right-Left Adjustment Adjust the Right-Left louversTo Use the Economy Operation Press the Economy button b-10 Minimum Heat OperationEconomy Operation About the Minimum Heat OperationTo select Swing Operation Press the Swing button b-12 Swing OperationCoil DRY Operation Manual Auto OperationCleaning and Care Function TroubleshootingSymptom Problem NormalAuto Restart Event of Power InterruptionOperating Tips Operation and PerformanceIndoor temperature SpecificationTemperature and Humidity Range Cooling Mode Dry Mode Heating Mode Outdoor temperature

MW09Y3H, MW12Y3H specifications

Friedrich MW09Y3H and MW12Y3H are the latest offerings in Friedrich's line of mini-split air conditioning systems, known for their efficiency, convenience, and advanced technology. These units are designed to provide optimal comfort in a wide range of environments, from residential spaces to small commercial establishments.

One of the main features of both the MW09Y3H and MW12Y3H models is their high energy efficiency rating. The seasonal energy efficiency ratio (SEER) of these systems is impressive, allowing for significant energy savings compared to traditional air conditioning units. This not only helps to lower electricity bills but also contributes to a reduced carbon footprint, making them an eco-friendly choice.

The MW09Y3H is ideal for smaller spaces, with a cooling capacity of 9,000 BTUs, making it well-suited for bedrooms or small living rooms. In contrast, the MW12Y3H offers a cooling capacity of 12,000 BTUs, providing the necessary power for larger areas. Both models utilize inverter technology, which allows the compressor to operate at variable speeds, ensuring consistent temperature control while minimizing energy consumption.

Another standout characteristic is the advanced filtration system integrated into both units. This system captures dust, allergens, and other pollutants, promoting better indoor air quality. This is particularly beneficial for individuals with allergies or respiratory conditions, as the filters can be easily removed and cleaned for maintenance.

Friedrich also emphasizes user convenience with these models. Both units come with a user-friendly remote control that allows for easy adjustments to temperature settings, fan speed, and mode selection from a distance. Additionally, the LED display on the indoor unit provides clear visibility of the current settings and temperature.

Furthermore, the MW09Y3H and MW12Y3H include a variety of operating modes, such as cooling, heating, dehumidifying, and fan-only modes, providing versatility for year-round comfort. The heat pump functionality allows these units to provide heating, making them a great choice for colder climates without the need for additional heating sources.

In summary, Friedrich's MW09Y3H and MW12Y3H mini-split air conditioning systems stand out due to their energy efficiency, advanced filtration, user-friendly controls, and versatile operating modes. They are a perfect choice for anyone seeking reliable and effective climate control solutions while prioritizing sustainability and comfort in their living spaces.