ELECTRICAL DATA

Wire Size

Use ONLY wiring size recommended for

 

single outlet branch circuit.

Fuse/Circuit

Use ONLY type and size fuse or HACR

Breaker

circuit breaker indicated on unit’s rating

 

plate. Proper current protection to the unit

 

is the responsibility of the owner.

Grounding

Unit MUST be grounded from branch

 

circuit through service cord to unit, or

 

through separate ground wire provided on

 

permanently connected units. Be sure that

 

branch circuit or general purpose outlet is

 

grounded.

Receptacle

The field supplied outlet must match plug on

 

service cord and be within reach of service

 

cord. Do NOT alter the service cord or plug.

 

Do NOT use an extension cord. Refer to

 

the table above for proper receptacle and

 

fuse type.

ELECTRIC SHOCK HAZARD.

Turn off electric power before service or installation.

All electrical connections and wiring MUST be installed by a qualified electrician and conform to the National Electrical Code and all local codes which have jurisdiction.

Failure to do so can result in property damage, personal injury and/or death.

The consumer - through the AHAM Room Air Conditioner Certification Program - can be certain that the AHAM Certification Seal accurately states the unit’s cooling and heating capacity rating, the amperes and the energy efficiency ratio.

7

Image 7
Contents Service & Parts Manual Table of Contents WALLMASTER≤ THRU-THE-WALL AIR Conditioners Limited Warranty Routine Maintenance RAC Serial Number Identification Guide Friedrich Room Model Number CodeOperating Performance DataElectric Shock Hazard Electrical DataMechanical components Functional ComponentsError Code Listings Testing the Electronic ControlChecking Room Temperature Activating Test ModeSystem Control Switch Test System Control SwitchSealed Refrigeration System Repairs Refrigeration System Sequence of OperationEquipment Must be Capable Hermetic Component ReplacementSealed Refrigeration System Repairs Equipment RequiredRotary Compressor Special Troubleshooting and Service Special Procedure in the Case of Motor Compressor BurnoutRefrigerant Charge Malfunction of Valve Normal Function of ValveProblem Possible Cause Action Cooling only Room AIR Conditioners Troubleshooting TipsReplace fuse, reset breaker. If repeats, check Problem Possible Cause Action Water spitting Heat / Cool Room AIR Conditioners Troubleshooting Tips Problem Possible Cause Action Wiring Diagram Models WS08B10A-C, WS10B10A-C Wiring Diagram Models WS16B30A-C Wiring Diagram Models WE10B33A-B, WE13B33B-B Wiring Diagram Models WE16B33A-B Wiring Diagram Models WY10B33A-B, WY13B33A-B 46A WS, WE & WY Series Chassis PartsElectrical Parts Wallmaster PartsSHROUD, Condenser WS, WE & WY Series Sleeve Parts WS WE WY Series Sleeve PartsWM-Svc-Prts-07

WS10B10A-C, WS10B30A-C, WS16B30A-C, WS13B30B-C, WY10B33A-B specifications

Friedrich manufactures a range of high-quality air conditioning units, including models WY13B33A-B, WS13B30B-C, WE16B33A-B, WS10B10A-C, and WS08B10A-C. These units are designed to offer reliable climate control for both residential and commercial spaces, while incorporating advanced technologies and energy-efficient features.

The WY13B33A-B model stands out with its impressive cooling capacity of 13,000 BTU, making it ideal for medium-sized rooms. It employs inverter technology, which not only optimizes energy consumption but also ensures a quieter operation by adjusting the compressor speed based on cooling demand. This model is equipped with a programmable thermostat, allowing users to set preferred temperatures and schedules, enhancing both comfort and efficiency.

The WS13B30B-C also features a robust cooling capability, paired with a sleek design that fits seamlessly into various interiors. Its user-friendly digital control panel and remote control operation enhance the overall user experience. Additionally, the unit is designed with energy-saving modes that further contribute to lower electricity bills without sacrificing performance.

The WE16B33A-B model is tailored for larger spaces, boasting a cooling capacity of 16,000 BTU. This makes it a great choice for open-plan areas or rooms with high ceilings. Its multi-speed fan and adjustable louvers provide customized airflow, ensuring that every corner of the room is adequately cooled. Notably, this model includes a dehumidification function that efficiently reduces humidity levels, promoting a more comfortable environment.

On the other hand, the WS10B10A-C and WS08B10A-C models are compact, making them perfect for smaller areas or specific applications such as bedrooms or home offices. Both units have a cooling capacity of 10,000 BTU and 8,000 BTU, respectively. They feature easy-to-use mechanical controls and are designed for simple installation, making them an excellent choice for individuals seeking an affordable yet effective cooling solution.

All Friedrich air conditioning units are built with durability and longevity in mind, incorporating high-quality materials and construction practices. Additionally, they boast reliable warranty options, ensuring peace of mind for consumers. In summary, Friedrich’s WY13B33A-B, WS13B30B-C, WE16B33A-B, WS10B10A-C, and WS08B10A-C models represent a blend of innovative technology, energy efficiency, and performance, tailored to meet diverse cooling needs.