INSTALLATION
e.Optional Remote Control (K775)
This control is included as part of the “NL Option”. Connect it to the “NL Option” box per instructions shipped with the option. (Not required with the
It can be purchased separately when the
To install, turn the power off. Remove the screw and lift the hinged door on the front of the control panel to expose the terminal strips. Connect the numbered leads to the appropriate terminals — 75 to 75, etc — on the
terminal strip and the green lead to the stud marked
with the symbol . Attach the control cord to the panel at the right of the terminal strip using a suitable clamp. Close the door and replace the screw. The Re- mote Control cord can be lengthened to any length by properly splicing an appropriate four conductor rubber- covered cable to the standard 25’ cord before connecting to the
f.Connecting for Air Carbon Arc
To use the
control leads and connect a jumper between #2 and #4 on the terminal strip on the front of the
WARNING: If the electrode leads to the wire are not disconnected per instructions, the wire feeder nozzle or gun and electrode will be electrically “hot”.
g.
A kit for field installation only, (order
h.Connecting for High Frequency Starting
As shipped, these welders can be used with a high fre- quency unit for improved automatic welding starting characteristics.
RATINGS
IP21 enclosure
Main Transformer insulation class 155 (F)
OPERATING INSTRUCTIONS
WARNING
|
|
|
|
|
|
|
|
|
|
|
| • | Do not touch electrically live parts or |
|
|
| • | Wear eye, ear and body protection. |
|
|
|
| electrode with skin or wet clothing. |
|
|
|
|
|
|
|
| • | Insulate yourself from work and |
|
|
|
|
|
|
|
|
| ground. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
ELECTRIC SHOCK |
|
|
|
| ARC RAYS |
|
|
|
|
can kill. |
|
|
|
| can burn. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| • | Keep your head out of fumes. |
|
|
| • | Keep flammable material away. |
•Use ventilation or exhaust to remove fumes from breathing zone.
FUMES AND |
| WELDING SPARKS |
GASES can be |
| can cause fire or |
dangerous. |
| explosion. |
DUTY CYCLE
The
To Set Polarity
Set the “Electrode Negative — Electrode Positive” switch to correspond to the polarity of the electrode cable connec- tion. This switch setting is necessary for proper operation of the Lincoln wire feeder attached to the power source.
Connect the electrode cable to the “Positive” or “Negative” studs depending upon the electrode polarity desired. Con- nect the work cable to the other studs.
To Start the Welder
Press the