P.C. BOARD TROUBLESHOOTING GUIDE

3.LED L3 indicates power is being applied to fault pro- tection relay 2CR, when wire feeder button is pressed or jumper is connected across 2 and 4.

4.LED L4 indicates when fault protection circuit is being activated.

5.LED L5 indicates a control signal is being supplied to the firing circuit. As the output control is varied, LED L5 should change brilliancy.

FIRING CIRCUIT P.C. BOARD

Machine settings

Terminals #2 and #4 jumpered on

for P.C. board

DC-1500. Output Control at

troubleshooting

DC-1500. Variable Voltage opera-

 

tion.

All nine light emitting diodes must be lit when the power source is turned on and the wire feed arc start button is pressed or a jumper is connected between 2 and 4.

1.LED L7 indicates AC power being supplied to P.C. board from control transformer T2. If not lit, check voltage across terminals 203 and 204 on the terminal strip lo- cated on the left side of the bottom fan baffle. Voltage should be approximately 115 volts. If no voltage indi- cates a supply problem, check wiring and transformer. If voltage is present, turn the machine off, remove the 12-pin harness plug from the P.C. board, turn the ma- chine back on and check the voltage across pins 2 and 3 on the plug. This should be approximately 115 volts.

If no voltage and there is voltage at terminals 203 and 204 on terminal strip TS-1 this indicates a broken lead or loose terminal on either lead 203 or 204.If voltage is present and LED L7 is not lit, replace P.C. board.

2.LED L8 indicates AC power being supplied to P.C. board from control transformer T3. If not, follow the same procedure as above in (1) for terminals 205 and 206 on terminal strip TS-1 and pins 5 and 6 on the connector.

3.LED L9 indicates AC power being supplied to P.C. board from control transformer T4. If not, follow the same procedure as above in (1) for terminals 207 and 208 on terminal strip TS-1 and pins 9 and 12 on the connector.

4.LED L1 through L6 indicate gate signals are being sup- plied to the main power SCR’s L1 through L6 respec- tively. If light L5 on the “Control/Fault Protection” circuit P.C. board and lights L7 through L9 on the “Fir- ing” circuit P.C. board are lit and LED’s L1 through L6 are not lit, check lead 231 between the “Firing” P.C. board and the “Control/Fault Protection” P.C. board that is not broken and is connected to each connector. If the lead shows continuity and LED L1 through L6 are not lit, replace the”Firing Circuit” P.C. board. If any one of the LED’s L1 through L6 is not lit and lights L7 through L9 are lit, replace the “Firing Circuit” P.C. board.

If troubleshooting guide indicates a possible P.C. board problem, the guide on page ? can be used to locate the problem.

OUTLINE FOR DC-1500 TROUBLESHOOTING GUIDE

NO WELDER OUTPUT

(INPUT CONTACTOR “ON” TERMINALS 2 AND 4 CLOSED)

CHECK CONTROL BOARD

LED L5

 

 

 

IF

 

OFF

 

 

IF

 

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CHECK

 

LED L1

CHECK “FIRING” BOARD

 

 

 

 

 

 

 

 

 

 

 

LED’S

 

 

 

IF

 

OFF

 

 

 

IF

 

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ALL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CHECK AC

 

 

 

REPLACE

 

NINE LIGHTS

INPUT TO

 

 

 

“CONTROL/

 

 

SHOULD

 

 

 

“CONTROL/

 

 

 

FAULT

 

 

BE

ON

 

 

 

FAULT

 

 

 

PROTECTION”

 

 

 

 

 

 

 

 

PROTECTION”

 

 

 

BOARD

IF YES

 

 

 

BOARD

 

 

 

 

 

 

 

 

 

 

 

IF

NO

POSSIBLE

 

 

 

 

 

 

CHECK GATE

 

 

 

 

 

 

 

 

 

 

 

 

DEFECTIVE T7

 

 

 

 

 

 

LEAD

CHECK

TRANSFORMER

CONNECTIONS

LED’S

 

 

 

 

 

 

 

 

 

TO SCR’S

L7, L8, L9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IF ONE

 

IF ON AND

 

 

 

 

 

 

 

 

 

 

OR MORE

 

OTHER LIGHTS

 

 

 

 

 

 

 

 

 

 

ARE

OUT

 

ARE

OUT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CHECK AC

 

REPLACE

 

 

 

 

 

 

 

 

 

 

INPUT TO

 

FIRING

 

 

 

 

 

 

 

 

 

 

BOARD,

 

BOARD

 

 

 

 

 

 

 

 

 

203-204, 205-206

 

 

207-208

POSSIBLE

DEFECTIVE TRANSFORMERS T2, T3, OR T4

MACHINE HAS OUTPUT BUT

ERRATIC

 

WELDING

TRIPS OFF

IMMEDIATELY

CHECK

 

PROCEDURE

 

 

 

CHECK FOR SHORT

 

 

 

 

 

 

BETWEEN ELECTRODE AND

CHECK MODE SWITCH FOR

WORK LEADS, REMOVE

PROPER POSITION FOR

EXTERNAL LEADS FROM

PROCESS

 

BEING USED

THE OUTPUT

TERMINALS

 

 

 

 

 

CHECK LED’S

IF TROUBLE STILL

L4, L5, L6

PERSISTS,

FOR EQUAL

CHECK LED L3 ON

BRILLIANCY

“CONTROL/FAULT

 

 

 

PROTECTION”

BOARD

IF LIGHTS ARE NOT ALL

 

 

APPROXIMATELY EQUAL

IF LIGHT GOES ON,THEN

BRIGHT, REPLACE

QUICKLY OUT WHEN START

FIRING P.C. BOARD

BUTTON IS PRESSED,

 

 

 

“CONTROL/FAULT

 

 

 

PROTECTION” BOARD IS

 

 

 

DEFECTIVE AND SHOULD

 

 

 

BE REPLACED

 

 

 

 

WARNING

 

• Have an electrician install and

 

service this equipment.

 

• Turn the input power off at the

 

fuse box before working on

 

equipment.

 

• Do not touch electrically hot parts.

ELECTRIC SHOCK

 

can kill.

 

-14-

Image 16
Contents Idealarc DC-1500June Safety California Proposition 65 WarningsElectric Shock can kill Welding and Cutting Sparks can Cause fire or explosion Précautions DE Sûreté Thank You Installation FallingOperating Instructions ARC RaysTo Set for Machine or Remote Control Approximate Voltage Voltage Control Setting Recommended SET-UP Procedures for NA-3/DC-1500, NA-5/DC-1500 NL Option Kit Maintenance Operation When Connected to the LT-3 or LT-34Troubleshooting Guide Electric Shock can killBoard Troubleshooting Guide ElectricFiring Circuit P.C. Board Diagrams Connection of DC-1500 to NA-5 Connection of DC-1500 to NA-3 All, LT-5 or LT-7 Dimension Print Precaucion Warnung