Lincoln Electric IM607 manual Safety Precautions, Routine and Periodic Maintenance

Page 19

12

MAINTENANCE

12

 

 

 

SAFETY PRECAUTIONS

WARNING

ELECTRIC SHOCK can kill.

Only qualified personnel should perform this maintenance.

Turn the input power OFF at the disconnect switch or fuse box before working on this equipment.

Do not touch electrically hot parts.

ommended. If the contacts are replaced reset the gap spacing to 0.015. Refer to figure C.1. Note in highly dirty environments where there is an abun- dance of conductive contaminants, use a low pres- sure air stream to clean the spark gap. Do not dis- turb the factory setting.

8.Inspect gas hose and inlet fitting for cracks or leaks.

9.Replace any unreadable labels or decals.

10.Verify that the machine and welding circuit is prop- erly grounded.

FIGURE C.1 SPARK GAP

WARNING

To avoid receiving a high frequency shock, keep the TIG torch and cables in good condition.

ROUTINE AND PERIODIC MAINTENANCE

1.Disconnect power supply lines to machine before performing periodic maintenance.

2.Periodically clean the inside of the machine with a low pressure air system. Be sure to clean the following components thoroughly.

Main Transformer

Electrode/Gas Output Receptacle

Polarity Switch

Rectifier Assembly

Arc Starter/Spark Gap Assembly

PC Boards

Fan Blades

3.Inspect welder output and control cables for fraying, cuts, and bare spots.

4.Keep TIG torch and cables in good condition.

5.Clean air louvers to ensure proper air flow and cooling.

6.The fan motor has sealed ball bearings which require no maintenance.

7.The arc starter spark gap spacing is factory set at 0.015 inch. It typically will not require periodic maintenance. Refinishing the contacts is not rec-

.015 Spark Gap

LEFT SIDE OF MACHINE

FAN MOTOR OR FAN BLADE REPLACEMENT

When installing a new fan blade or fan motor be sure to maintain proper shaft spacing per Figure C.2 below.

.30

Figure C.2

SQUARE WAVE TIG 175

Image 19
Contents Square Wave TIG Safety Depends on YouCalifornia Proposition 65 Warnings SafetyElectric Shock can kill Iii Welding Sparks can cause fire or explosionSûreté Pour Soudage a L’Arc Précautions DE SûretéThank You Table of Contents Square Wave TIG InstallationTilting Select Suitable LocationStacking Lifting and MovingInput Supply Connections Input Reconnect ProcedureWork Cable Connection Output ConnectionsConnections for TIG Gtaw Welding TIG Torch ConnectionConnections for Stick Smaw Welding Remote Control ConnectionStick Electrode Cable and Work Cable Connection Included Equipment Safety PrecautionsOperation General DescriptionPower Switch & Light Turns power on Controls and SettingsWelding in TIG Mode 4-STEP Welding in TIG Mode 2 StepOperating Steps Benefits of the Square Wave Design Remote Control OperationGtaw Process Welding in Stick ModeRecommended Electrode Amperage Ranges Square Wave TIG Smaw ProcessOptional Accessories AccessoriesFAN Motor or FAN Blade Replacement MaintenanceSafety Precautions Routine and Periodic MaintenanceHOW to USE Troubleshooting Guide TroubleshootingPossible Areas SymptomsCourse of Action Troubleshooting Square Wave TIG APR96 TIG Mode ProblemsTIG Welding Problems Troubleshooting Field Service Facility for technical Symptoms Misadjustmentss Course of ActionWiring Diagram Square Wave TIG 175 240/380/415/1/50/60 Wiring DiagramDimension Print Square Wave TIG Square Wave TIG $700.00 Basic CoursePrecaucion Aviso DE