OPERATION

B-3

 

 

 

ENGINE CONTROLS

IGNITION SWITCH

When placed in the “ON” position, this switch ener- gizes the fuel solenoid. When placed in the “OFF” posi- tion, the flow of fuel to the injection pump is stopped to shut down the engine.

“IDLER” SWITCH

The idler switch has

two

positions, “HIGH” and

“AUTO”.

 

 

When in “HIGH” (

) position, the engine will run

continuously at high idle.

 

When in “AUTO” (

/

) idle position, the idler

operates as follows:

 

 

a.Welding

When the electrode touches the work, the welding arc is initiated and the engine accelerates to full speed.

After welding ceases (and no auxiliary power is being drawn), the engine will return to low idle after approximately 10 to 14 seconds.

b.Auxiliary Power

With the engine running at low idle and auxiliary power for lights or tools is drawn (approximately 100-150 watts or greater) from the receptacles, the engine will accelerate to high speed. If no power is being drawn from the receptacles ( and not weld- ing) for 10-14 seconds, the idler reduces the engine speed to low idle.

ENGINE TEMPERATURE GAUGE

Displays the coolant temperature in the engine block.

ENGINE OIL PRESSURE GAUGE

Displays the oil pressure to the engine. When the engine starts running, watch for the oil pressure to build up. If no pressure shows within 30 seconds, stop the engine and consult the engine instruction manual.

BATTERY CHARGING AMMETER

Displays the current going from the charging alternator into the batteries. It is normal for charging current to be high (above 15 amps) after starting or when the batter- ies are ‘low’ on charge.

ENGINE HOUR METER

The engine hour meter records the total running time on the engine in hours. It can be used to keep a record of maintenance on the engine and or welder.

ENGINE PROTECTION SYSTEM

The engine protection system shuts down the engine under high coolant temperature or low engine oil pres- sure conditions by allowing the fuel solenoid valve to close.

AIR INTAKE SHUT-OFF

The air intake shut-off is a manually engaged device that blocks all intake air from entering the engine.

To shut down the engine, simply pull the emergency stop handle on the lower control panel.

The air intake shut-off device must be reset manually inside the welder.

Place the ignition toggle switch in the "OFF" position

Manually turn the air intake shut-off reset handle such that the handle is in-line with the air intake hoses. The air intake shut-off is located on the top of the engine between the muffler and air filter.

WARNING

Muffler and Engine may be hot!

IMPORTANT: Before restarting engine, verify that the air intake shut-off is in the open position. DO NOT ATTEMPT TO START ENGINE WITH THE AIR INTAKE SHUT-OFF IN THE CLOSED POSITION. This may cause severe damage to the engine.

SAE-400 SEVERE DUTY

Image 15
Contents IM727 California Proposition 65 Warnings SafetyElectric Shock can kill Cylinder may explode if damaged Sûreté Pour Soudage a L’Arc Précautions DE SûretéThank You Table of Contents Installation Technical Specifications SAE-400 Severe DutyHeight Width Depth Weight Angle of Operation Safety PrecautionsLOCATION/VENTILATION StackingPRE-OPERATION Engine Service Battery Connection Engine BREAK-INEngine Cooling System Table A.1 Combined Length of Electrode Work Cables Spark Arrestor Welding Output Cables Machine GroundingGeneral Description Safety InstructionsOperation Operating InstructionsDuty Cycle Design Features and AdvantagesFor Auxiliary Power Other FeaturesEngine Controls Welder Controls Remote ControlAuxiliary Power Controls Polarity SwitchBREAK-IN Period Engine OperationTypical Fuel Consumption Starting InstructionsAccessories Optional Field Installed AccessoriesK1690-1 Gfci Receptacle KIT Engine OIL Change MaintenanceRoutine Maintenance Periodic MaintenanceCooling System Bearing MaintenanceCommutator and Brush Maintenance Fuel PRE-FILTER/WATER Separator AssemblyEngine Maintenance Components Make Part Number Water Separator ElementSecondary Fuel Filter Gfci Receptacle Testing and RESET- Ting Procedure For machines with separate spark arresting unitFor machines with integral spark arresting muf- flers HOW to USE Troubleshooting Guide TroubleshootingSymptoms Misadjustments Course of Action Possible AreasContact your local Lincoln Contact your local Lincoln Authorized Field Service Facility Faulty receptacles Diagrams WiringSevere Duty SAE-400M8869-23 Dimension PrintSAE-400 Sever Duty Precaucion Aviso DE