Lincoln Electric IM727 manual Gfci Receptacle Testing and RESET- Ting Procedure

Page 22

D-4

MAINTENANCE

D-4

 

 

 

SPARK ARRESTOR

WARNING

Spark Arrestor and Muffler may be hot!

Allow engine to cool before servicing spark arrestor!

Do not operate engine while servicing spark arrestor!

For machines with separate spark arresting unit:

Service the spark arrestor every 100 hours of opera- tion or twice a year, which ever occurs first.

Service as follows:

1.Stop engine and allow to cool.

2.Loosen clamp and remove spark arrestor from machine.

3.Remove locknut on top of spark arrestor housing and lift off cap.

4.Separate plates and clean if necessary.

5.Inspect plates and housing for holes or cracks. Replace spark arrestor if damaged.

6.Assemble spark arrestor using reverse order: step 3, then step 2.

For machines with integral spark arresting muf- flers:

Service spark arrestor every 250 hours.

Service as follows:

1.Stop engine and allow to cool.

2.Remove clean out plug from the side of the spark arrestor.

3.Without damaging the spark arrestor, gently tap on the shell near the clean out plug.

4.Once particles are removed, replace the clean out plug.

GFCI RECEPTACLE TESTING AND RESET- TING PROCEDURE

The GFCI receptacle should be properly tested at least once every month or whenever it is tripped. To proper- ly test and reset the GFCI receptacle:

If the receptacle has tripped, first carefully remove any load and check it for damage.

If the equipment has been shut down, it must be restarted.

The equipment needs to be operating at high idle speed and any necessary adjustments made on the control panel so that the equipment is providing at least 80 volts to the receptacle input terminals.

The circuit breaker for this receptacle must not be tripped. Reset if necessary.

Push the "Reset" button located on the GFCI recep- tacle. This will assure normal GFCI operation.

Plug a night-light (with an "ON/OFF" switch) or other product (such as a lamp) into the GFCI receptacle and turn the product "ON".

Push the "Test" button located on the GFCI recepta- cle. The night-light or other product should go "OFF".

Push the "Reset" button, again. The light or other product should go "ON" again.

If the light or other product remains "ON" when the "Test" button is pushed, the GFCI is not working prop- erly or has been incorrectly installed (miswired). If your GFCI is not working properly, contact a qualified, certi- fied electrician who can assess the situation, rewire the GFCI if necessary or replace the device.

SAE-400 SEVERE DUTY

Image 22
Contents IM727 Safety California Proposition 65 WarningsElectric Shock can kill Cylinder may explode if damaged Précautions DE Sûreté Sûreté Pour Soudage a L’ArcThank You Table of Contents Technical Specifications SAE-400 Severe Duty InstallationHeight Width Depth Weight Stacking Safety PrecautionsLOCATION/VENTILATION Angle of OperationPRE-OPERATION Engine Service Engine BREAK-IN Battery ConnectionEngine Cooling System Machine Grounding Spark ArrestorWelding Output Cables Table A.1 Combined Length of Electrode Work CablesOperating Instructions Safety InstructionsOperation General DescriptionOther Features Design Features and AdvantagesFor Auxiliary Power Duty CycleEngine Controls Polarity Switch Remote ControlAuxiliary Power Controls Welder ControlsStarting Instructions Engine OperationTypical Fuel Consumption BREAK-IN PeriodOptional Field Installed Accessories AccessoriesK1690-1 Gfci Receptacle KIT Periodic Maintenance Maintenance Routine Maintenance Engine OIL ChangeFuel PRE-FILTER/WATER Separator Assembly Bearing MaintenanceCommutator and Brush Maintenance Cooling SystemWater Separator Element Engine Maintenance Components Make Part NumberSecondary Fuel Filter For machines with separate spark arresting unit Gfci Receptacle Testing and RESET- Ting ProcedureFor machines with integral spark arresting muf- flers Troubleshooting HOW to USE Troubleshooting GuidePossible Areas Symptoms Misadjustments Course of ActionContact your local Lincoln Contact your local Lincoln Authorized Field Service Facility Faulty receptacles Wiring DiagramsSAE-400 Severe DutyDimension Print M8869-23SAE-400 Sever Duty Precaucion Aviso DE