Friedrich 115 Volts UE08, UE08, UE10, UE12 manual Electrical Parts, Compressor, Capacitor

Page 7

2.2.3 SHROUD

1.Remove the fan. (Refer to section 2.2.2)

2.Remove the screw which fastens the shroud.

3.Remove the shroud. (See Fig. 9)

4.Re-install the components by referring to the removal procedures, above.

2.3 ELECTRICAL PARTS

2.3.1 MOTOR

1.Remove the cabinet. (Refer to section 2.1.2)

2.Remove the clamp cord and disconnect the wire housing in control box. (Refer to section 2.1.3)

3.Remove the turbo fan. (Refer to section 2.2.2)

4.Remove the fan. (Refer to section 2.2.2)

5.Remove the 4 or 2 screws which fasten the motor. (See Fig. 10)

6.Remove the motor.

7.Re-install the components by referring to the removal procedures, above.

2.3.2 COMPRESSOR

1.Remove the cabinet. (Refer to section 2.1.2)

2.Discharge the refrigerant system using a FreonTM Recovery System.

Install a valve for the recovery, before venting the Freon. Remove the valve when finished.

3.Disconnect the 3 leads from the compressor.

4.After purging the unit completely, unbraze the suction and discharge tubes at the compressor connections.

5.Remove the 3 nuts and the 3 washers which fasten the compressor. (See Fig. 11)

6.Remove the compressor.

7.Re-install the components by referring to the removal procedures, above.

2.3.3 CAPACITOR

1.Remove the control box. (Refer to section 2.1.3)

2.Remove knobs and the tips which fasten the display panel.

3.Remove 2 screws and unfold the control box. (See Fig. 12)

4.Remove the Rotary Switch.

5.Remove the screw and the clamp which fastens the capacitor. (See Fig. 12)

6.Disconnect all the leads on the capacitor terminals.

7.Re-install the components by referring to the removal procedures, above.

—7—

Figure 9

Figure 10

Figure 11

Figure 12

Image 7
Contents Thru-the-Wall Series Preface ContentsFor UE08A13B/UE10A33B/UE12A33B SpecificationsVentilation FeaturesControl Locations OperationCabinet Disassembly InstructionsMechanical Parts Front GrilleORIFICE, Heater Assy and Turbo FAN AIR Handling PartsCompressor Electrical PartsCapacitor Rotary Switch Power CordThermostat Capillary Tube Refrigeration CycleCondenser EvaporatorPage Pulling Vacuum Outside Dimensions Troubleshooting GuidePiping System Troubleshooting Guide Fails to Start Complaint Cause Remedy Room AIR Conditioner Voltage Limits Complaint Cause Remedy Circuit Diagram Schematic DiagramModel UE08A13B/UE10A33B/UE12A33B Exploded ViewModel UE08A13B Replacement Parts ListModel UE10A33B Model UE12A33B Friedrich AIR Conditioning CO