Friedrich 115 Volts UE08 manual Refrigeration Cycle, Condenser, Evaporator, Capillary Tube

Page 9

2.4 REFRIGERATION CYCLE

CAUTION

Discharge the refrigerant system using a FreonTM Recovery System.

Install a valve for the recovery before venting the Freon. Remove the valve when finished.

2.4.1 CONDENSER

1.Remove the cabinet. (Refer to section 2.1.2)

2.Remove the brace and the shroud cover. (Refer to section 2.2.1)

3.Remove the 5 screws which fasten the condenser.

4.After discharging the refrigerant completely into a FreonTM Recovery System, unbraze the interconnecting tube at the condenser connections.

5.Remove the condenser.

6.Re-install the components by referring to the notes

– on pages 13-14. (See Fig. 16)

2.4.2 EVAPORATOR

1.Remove the cabinet. (Refer to section 2.1.2)

2.Discharge the refrigerant completely – into a FreonTM Recovery System.

3.Remove the 2 screws which fasten the evaporator at the left side and the right side.

4.Move the evaporator sideward carefully and then unbraze the interconnecting tube at the evaporator connectors.

5.Remove the evaporator.

6.Re-install the components by referring to the notes

– on pages 13-14. (See Fig. 17)

2.4.3 CAPILLARY TUBE

1.Remove the cabinet. (Refer to section 2.1.2)

2.After discharging the refrigerant completely – into a FreonTM Recovery System, unbraze the interconnecting tube at the capillary tube.

3.Remove the capillary tube.

4.Re-install the components by referring to the notes

– on page 13-14.

Figure 16

Figure 17

—9—

Image 9
Contents Thru-the-Wall Series Preface ContentsFor UE08A13B/UE10A33B/UE12A33B SpecificationsControl Locations FeaturesOperation VentilationMechanical Parts Disassembly InstructionsFront Grille Cabinet ORIFICE, Heater Assy and Turbo FAN AIR Handling PartsElectrical Parts CompressorCapacitor Power Cord Rotary SwitchThermostat Condenser Refrigeration CycleEvaporator Capillary TubePage Pulling Vacuum Troubleshooting Guide Outside DimensionsPiping System Troubleshooting Guide Fails to Start Complaint Cause Remedy Room AIR Conditioner Voltage Limits Complaint Cause Remedy Circuit Diagram Schematic DiagramModel UE08A13B/UE10A33B/UE12A33B Exploded ViewModel UE08A13B Replacement Parts ListModel UE10A33B Model UE12A33B Friedrich AIR Conditioning CO