Friedrich UE08, UE10, UE12, 115 Volts UE08 AIR Handling Parts, ORIFICE, Heater Assy and Turbo FAN

Page 6

2.2 AIR HANDLING PARTS

2.2.1ORIFICE, HEATER ASSY AND TURBO FAN

1.Remove the front grille. (Refer to section 2.1.1)

2.Remove the cabinet. (Refer to section 2.1.2)

3.Remove the 2 screws which fasten the evaporator at the left side and the right side. (See Fig. 4)

4.Move the evaporator sideward carefully.

5.Remove the 2 terminals carefully

(See Fig. 5, Electric Heater Model only)

6.Remove the 4 screws which fasten the orifice. (See Fig. 5)

7.Remove the orifice. (See Fig. 5)

8.Using handheld pliers, remove the clamp which secures the turbo fan. (See Fig. 6)

9.Remove the turbo fan with pliers or your hand, without touching blades. (See Fig. 7)

10.Re-install the components by referring to the removal procedures, above.

2.2.2FAN

1.Remove the cabinet. (Refer to section 2.1.2)

2.Remove the brace and shroud cover. (Refer to section 2.2.1)

3.Remove the 6 screws which fasten the condenser.

4.Move the condenser sideways carefully.

5.Using handheld pliers, remove the clamp which secures the fan.

6.Remove the fan. (See Fig. 8)

7.Re-install the components by referring to the removal procedures, above.

Figure 4

Figure 5

Figure 6

Figure 7

Figure 8

—6—

Image 6
Contents Thru-the-Wall Series Contents PrefaceSpecifications For UE08A13B/UE10A33B/UE12A33BOperation FeaturesControl Locations VentilationFront Grille Disassembly InstructionsMechanical Parts CabinetAIR Handling Parts ORIFICE, Heater Assy and Turbo FANElectrical Parts CompressorCapacitor Power Cord Rotary SwitchThermostat Evaporator Refrigeration CycleCondenser Capillary TubePage Pulling Vacuum Troubleshooting Guide Outside DimensionsPiping System Troubleshooting Guide Fails to Start Complaint Cause Remedy Room AIR Conditioner Voltage Limits Complaint Cause Remedy Schematic Diagram Circuit DiagramExploded View Model UE08A13B/UE10A33B/UE12A33BReplacement Parts List Model UE08A13BModel UE10A33B Model UE12A33B Friedrich AIR Conditioning CO