Read completely, then follow step-by step.

Select the Best Location

Step 1. To prevent vibration and noise, make sure the unit is installed securely and firmly

Step 2. If possible, install the unit where sunlight does not shine directly on the unit.

Step 3. The outside of the cabinet must extend outward for at least 11" and there should be no obstacles, such as a fence or wall, within 20" from the back of the cabinet because it will prevent heat radiation of the condenser.

Restriction of outside air will greatly reduce the cooling efficiency of the air conditioner.

Step 4. Install the cabinet with a very slight tilt (about 1/2") downward toward the outside.

CAUTION: All side louvers of the cabinet must remain exposed to the outside of the structure.

Window Requirements

Step 1. These instructions are for a standard double hung window. You will need to modify them for other types of windows.

Step 2. The air conditioner can be installed without the frame curtain if needed to fit in a narrow window. See the window opening dimensions to the right.

Step 3. All supporting parts must be secured to firm wood, masonry, or metal.

Step 4. The electric outlet must be within reach of the power cord.

Storm Window Requirements

COOLED

AIR

30"~60"

22" to 36" (With accordion panels)

15" min

(With frame curtain) Stool

Interior wall 18 1/2" min

(Without frame curtain)

FENCE

AWNING

HEAT

RADIATION

About 1/2"

Over 20"

1/4 Bubble

Level

Offset

1/2" to 11/4" Sill Exterior

A storm window frame will not allow the air conditioner to tilt toward the outside and will keep it from draining properly. To adjust for this, attach a piece of wood to the stool.

WOOD PIECES–

Width: Minimum 1 1/2"(38mm)

Length: Long enough to fit inside the window frame.

Thickness: To determine the thickness, place a piece of wood on the stool to make it 1/2" higher than the top of the storm window frame. Attach securely with nails or screws provided.

Wood

1/2" higher than frame

Stool

Storm window frame

11

Image 12
Contents Room Air Conditioner Installation and Operating Manual KStar Table of Contents Introduction Before Operating Your UnitSafety Precautions Be sure not to do this Be sure to follow the instructionsSharp EDGES! The edges of the case can be Sharp How to Operate Your KStar Room Air Conditioner ControlsVentilation Air DirectionGrille and Case Outdoor CoilsAir Filter Drainage Installation Instructions Before You Begin Electrical Data Tools You Will NeedElectrical safety Adapter plug Metal screw Receptacle coverFeatures Installation HardwareSelect the Best Location Window RequirementsStorm Window Requirements Preparing the Unit for Installation Install the Case in the Window Pull the window down behind the top Mounting railInstall the Air Conditioner in the Case To Reverse the Grille OpeningTroubleshooting Tips Room AIR Conditioners Limited Warranty Friedrich AIR Conditioning CO