GE 45603 manual Load Sensing, Restoring Factory Defaults, Over-Current Protection

Page 10

Load Sensing

Load sensing is disabled when shipped from the factory. This feature can be enabled if desired. Setting parameter 29 to a value of 1 will enable the Load Sense function.

-Parameter No: 29

-Length: 1 Byte

-Valid Values = 0 or 1 (default 0)

Note: When replacing a burned-out light bulb, the load sensing feature (if enabled) will automatically turn the light ON when the new bulb is installed even if the Z-wave module was turned OFF.

Restoring Factory Defaults

All Configuration Parameters can all be restored to their factory default settings by using your primary controller to reset the device.

Over-Current Protection

Over-current protection is provided by an internal fuse which is not user serviceable. Check your home’s circuit breakers before concluding that the product must be replaced.

Interoperability with Z-WaveDevices

A Z-Wavenetwork can integrate devices of various classes, and these devices can be made by different manufacturers. Although every Z-Wave certified product is designed to work with all other Z-Wave certified products, your controller must include the appropriate device classifications in order to control non-lighting Z-wave devices. As an example, the 45600 basic remote is designed only for controlling Z-Wave

Image 10
Contents Fluorescent & Appliance Module Introduction There are no user serviceable parts in this unit Risk of Fire Risk of Electrical Shock Risk of Burns GE Z-Wave Network Wireless RangeThings to consider regarding RF range Type of Construction Key Features Basic Operation Remote ControlManual Control Advanced Operation Over-Current Protection Restoring Factory DefaultsLoad Sensing Interoperability with Z-WaveDevicesWarranty FCC Specifications Page