Lincoln Electric 4R220 manual Troubleshooting

Page 23

E-2

TROUBLESHOOTING

E-2

 

Observe all Safety Guidelines detailed throughout this manual

 

 

 

 

PROBLEMS

(SYMPTOMS)

POSSIBLE

CAUSE

RECOMMENDED

COURSE OF ACTION

 

 

 

 

 

 

 

 

The wire feeder does not feed wire

1. Verify the power source is turned

 

and the drive rolls do not spin.

 

on.

 

 

2.

Verify the circuit breaker for the

 

 

 

wire feeder on the power source

 

 

 

has not tripped.

 

 

3.

Verify power is being supplied to

 

 

 

the wire feeder.

 

 

 

 

The wire feeds erratically.

1. Verify the correct drive rolls and

 

 

 

inner wire guide are installed in

 

 

 

the wire drive.

 

 

2.

Check for sharp bends in the gun

 

 

 

liner or conduit.

 

 

3.

Examine the contact tip for wear

 

 

 

and proper size. Replace as nec-

 

 

 

essary.

 

 

4.

Check the gun liner and conduit.

 

 

 

The welding electrode should

 

 

 

slide easily through both.

 

 

5.

Verify the proper gun liner is

 

 

 

installed.

 

 

6. Verify the pressure arms are set

 

 

 

properly. Too much pressure may

 

 

 

crush the wire.

 

 

7.

Inspect the motor for worn brush-

 

 

 

es.

 

 

 

 

No shielding gas

1. Verify the gas supply is turned on

 

Variable or "hunting" arc.

 

and not empty.

 

 

2.

Check the gas hose for cuts.

 

 

 

Make sure it is not crushed.

 

 

3.

Verify the shielding gas hose is

 

 

 

connected to the gun bushing or

 

 

 

welding gun.

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

AutoDrive™ 4R220

Image 23
Contents AutoDrive4R220 California Proposition 65 Warnings SafetyE C T R I C S H O C K c a n kill Welding and Cutting Sparks can Cause fire or explosion Sûreté Pour Soudage a L’Arc Précautions DE SûretéThank You Table of Contents Gearing Wire Feed Speed RANGE-WIRE Size InstallationLocation Safety PrecautionsWeld Cable Size Coaxial Weld Cable WorkWire Feeder 4INSTALLATIONA-4Wire Drive CABLE, K1785-XX Power SourceBuild UP of Shielding GAS MAY Harm Health or Kill Shielding GAS ConnectionElectric Shock can kill Procedure to Install Drive Rolls and Wire GuidesLoading Wire Pressure ARM AdjustmentConduit Installation System SET-UP SystemOperation Safety PrecautionsProduct Description Optional Kits and Accessories Drive Roll Kits 4 Roll Drive AccessoriesK1500-5 Gun Receiver Bushing compatible K2175-1 Routine Maintenance MaintenanceHOW to USE Troubleshooting Guide TroubleshootingTroubleshooting Output Problems Diagrams Wiring Diagram Autodrive 4R220 FeederPrintdimension AutoDrive 4R220 Aviso DE Keep your head out of fumes Turn power off before servicing