TROUBLESHOOTING | ||
| Observe all Safety Guidelines detailed throughout this manual |
|
|
|
|
PROBLEMS
(SYMPTOMS)
POSSIBLE
CAUSE
RECOMMENDED
COURSE OF ACTION
|
|
|
|
|
| Output Problems |
|
Variable or "hunting" arc. | 1. Check for proper size contact. |
| |
|
| Make sure the contact tip is not |
|
|
| worn, free of spatter and not melt- |
|
|
| ed. |
|
| 2. | Clean and tighten all electrode |
|
|
| and work connections. |
|
| 3. | Verify the proper polarity is being |
|
|
| used for the weld procedure. |
|
| 4. | Make sure the proper electrode |
|
|
|
| |
| 5. | Check the gas flow rate and mix- |
|
|
| ture. |
|
| 6. | Verify the gun bushing is tightly |
|
|
| mounted to the wire drive. |
|
| 7. | Verify the gun is tightly mounted |
|
|
| to the gun bushing. |
|
| 8. | Verify the electrode lead is con- |
|
|
| nected to the proper connection |
|
|
| block on the feed head. |
|
| 9. | Inspect the motor for worn brush- |
|
|
| es. |
|
|
|
| |
The motor overload errors occur. | 1. Check for sharp bends in the gun |
| |
|
| liner and conduit. |
|
| 2. | Examine the contact tip for wear |
|
|
| and proper size. Replace as nec- |
|
|
| essary. |
|
| 3. | Check the gun liner and conduit. |
|
|
| The welding electrode should |
|
|
| slide easily through both. |
|
| 4. | Verify the proper gun liner is |
|
|
| installed. |
|
| 5. | Reduce the pressure arm setting. |
|
|
|
|
|
CAUTION