PIPELINER NR-207+AWS: E71T8-K6 Self-Shielded Flux-Cored (FCAW-S) Wire Electrode

Optimum performance on vertical down hot, fill and cap passes on standard cross-country pipelines and arctic grade pipe. Excellent crack resistance, CTOD, and Charpy V-Notch properties. Recommended for API Pipe Grades X42 through X70.

characteristics and superior feedability.

Manufactured to actual lot control. Actual certificates of conformance are available upon request.

WELDING POSITIONS

1G

2F

2G

ADVANTAGE LINCOLN

Produces quality welds in moderate wind conditions with no tenting.

Our quality driven manufacturing system – certified to ISO 9001 – and our exceptionally high grade raw materials mean every coil of Innershield delivers great arc

TYPICAL APPLICATIONS

Standard cross country pipelines.

Arctic grade pipe.

Use these wires instead of stick for improved productivity on pipeline projects.

3G

4G

5G

CONFORMANCE

AWS A5.29-98: E71T8-K6

ASME SFA-5.29: E71T8-K6

MECHANICAL PROPERTIES - As Required per AWS A5.29-98

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Charpy V-Notch

 

 

 

Yield Strength

Tensile Strength(1)

Elongation(1)

ft•lbf (Joules)

 

Hardness

 

psi (MPa)

psi (MPa)

(%)

@ -20°F (-29°C) @-40°F (-40°C)

Rockwell B

 

 

 

 

 

 

 

 

 

 

Requirements

58,000

(400)

70,000

- 90,000

20

20 (27)

Not .

 

Not

AWS E71T-K6

min.

(483

- 620)

min.

min.

Required

 

Required

 

 

 

 

 

 

 

 

 

 

Typical Results 58,000

-

64,000

75,000

- 80,000

20 - 33

103 - 116

109

.

84 - 90

 

(400

-

441)

(517

- 551)

 

(176 - 230)

(147) ..

 

(1)The strength and elongation properties reported were obtained from a .505” tensile specimen artificially aged at 220°F (104°C) for 48 hours, as permitted by AWS A5.29-98. A naturally aged tensile specimen may take months to achieve the specified properties. The time required for the natural aging of weld deposits is dependent upon ambient conditions, weld- ment geometry, the metallurgical structure of the weld deposit and other factors.

NOTE: Pipeliner elec- trodes are manufactured under lot control. A Certificate of Test show- ing actual deposit chem- istry and mechanical properties per AWS A5.29 is available on request from the factory for every lot of electrode. (Fax 216-383-8386).

DIAMETERS / PACKAGING

 

 

 

 

 

 

 

 

 

Diameter

14 Lb. (6.3 kg) Coil

in.

(mm)

[ 56 Lb. (25.4 kg)

 

 

Master Sealed Pail ]

 

 

 

5/64

(2.0)

ED030924

TYPICAL OPERATING

PROCEDURES

 

 

 

 

 

Diameter

Parameters

5/64 in. (2.0 mm)

 

 

Polarity

DC-

CTWD(1) – in (mm)

3/4 (19)

Wire Weight – lbs/in (g/m)

1.04/1000 (18.57)

Wire Feed Speed – in/min (m/min)

70-130 (1.7-3.3)

Arc Voltage (volts)

18-21

Approx. Current (amps)

210-305

Melt-off Rate – lbs/hr (kg/hr)

4.3-8.1 (2.0-3.7)

Deposition Rate – lbs/hr (kg/hr)

3.6-6.7 (1.6-3.0)

(1)CTWD (Contact Tip to Work Distance). Subtract 1/4" to calculate Electrical Stickout.

DEPOSIT COMPOSITION - As Required per AWS A5.29-98

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

%C

%Mn

%P

%S

%Si

%Al

%Ni

%Cr

%Mo

%V

 

 

Requirements

.15

.50-

.03

.03

.80

1.80

.40-

.20

.15

.05

 

 

AWS E71T8-K6

 

 

max.

1.50

max.

max.

max.

max.

1.00

max.

max.

max.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Typical Results .06

1.21

.007

<.003

.25

.96

.82

.03

.02

<.01

 

Pipeliner

13

www.lincolnelectric.com

Image 13
Contents Premium Pipe Welding Consumables Electric Company MIG Gmaw PSL2 PSL1Pipe Grades Wall thickness 3/4 in mmProduct Selection Root Pass Welding Only API 5L Pipe GradesCellulosic All Position Stick Smaw Electrodes Consumable Selection GuideLow Hydrogen Stick Smaw Electrodes Innershield Self-Shielded Flux-Cored FCAW-S Electrodes MIG Gmaw ElectrodesOutershield Gas-Shielded Flux-Cored FCAW-G Electrodes Welding Positions Advantage Lincoln Diameters / Packaging Typical Operating ProceduresTypical Applications ConformanceTypical applications include high- yield pipe steels Welding Positions ConformanceMechanical Properties As Required per AWS A5.5-96 Deposit Composition As Required per AWS A5.5-96Deposit Composition As Required per AWS A5.1-91 AWS A5.1 E7016 H4 Asme SFA-5.1 E7016 H4Diameters / Packaging Welding PositionsDiffusible Hydrogen AWS A5.5 E8018-G H4 Asme SFA-5.5 E8018-G H4Mechanical Properties As Required per AWS A5.182001 AWS A5.18-2001 ER70S-G Asme SFA-5.18 ER70S-GMechanical Properties As Required per AWS A5.29-98 AWS A5.29-98 E71T8-K6 Asme SFA-5.29 E71T8-K6Deposit Composition As Required per AWS A5.29-98 Deposit Composition As Required per AWS A5.29 Consistently high CVN properties, even down to -40˚F -40˚C75-80% Ar / Balance CO2 Flow Rate 40-50 CFH 19-24 l/min Welding Positions Shielding GASMechanical Properties As Required per AWS A5.20-95 Deposit COMPOSITION-As Required per AWS A5.20-95All position wire designed to weld pipe up to Test Results Lincoln International Headquarters