Lincoln Electric 2HBG Welding Positions Advantage Lincoln, Typical Applications, Conformance

Page 8

PIPELINER 6P+ AWS: E6010 Cellulosic All-Position Stick (SMAW) Electrode

Pipeliner 6P+ is an all-position cellulosic pipe electrode designed especially for vertical down root pass welding. This electrode is based on a long-time favorite among cross- country pipeline welders.

Manufactured under a quality system certified to ISO 9001 requirements.

Manufactured to actual lot control. Actual certificates of conformance are available upon request.

WELDING POSITIONS

1G

2F

2G

3G

3G

4G

ADVANTAGE LINCOLN

All-position; particularly good for vertical and overhead.

Light slag with little slag interference for easy arc control. Easy slag removal, smooth bead.

Deep penetration with maximum dilution.

Capable of x-ray quality welds, even out-of-position.

TYPICAL APPLICATIONS

Designed especially for all-position vertical down root pass welding.

5G

5G

CONFORMANCE

AWS A5.1: E6010

ASME SFA-5.1: E6010

CSA W48.01: E41010

EN499: E 42 3 C 25

MECHANICAL PROPERTIES - As Required per AWS A5.1-91

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Charpy V-Notch

 

 

 

Yield Strength

Tensile Strength

Elongation

ft•lbf (Joules)

 

 

 

psi (MPa)

psi (MPa)

(%)

@ -20ºF (-29ºC)

 

 

 

 

 

 

 

 

 

 

 

Required

48,000 (330)

60,000

(410)

22

20

(27)

 

 

AWS E6010 (as-welded)

min.

min.

min.

min.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Typical Results

 

 

 

 

 

 

 

 

 

 

 

As-welded

57,000

-

76,000

72,900

-

86,200

24 - 33

38

- 63

 

 

 

(393

-

524)

(503

-

594)

(51

- 85)

 

 

 

 

 

 

Stress-relieved(1)

51,000

-

64,000

67,000

-

78,000

30 - 34

45

- 53

 

 

1 hr @ 1150°F (612°C)

(352

-

579)

(462

-

538)

(61

- 72)

 

 

 

 

(1)Data provided for information only – not part of AWS classification.

NOTE: Pipeliner electrodes are manufactured under lot control. A Certificate of Test showing actual deposit chemistry and mechanical properties per AWS A5.1 (DC+ only) is available on request from the factory for every lot of electrode.

(Fax 216-383-8386).

DIAMETERS / PACKAGING

TYPICAL OPERATING PROCEDURES

Diameter

10 Lb. (4.5 kg)

50 Lb. (22.7 kg)

in.

(mm)

Easy Open Cans

Easy Open Cans

 

 

[ 60 lb. (27.2 kg) Master ]

 

 

 

Polarity

Current (Amps)

1/8” 5/32” 3/16”

1/8

(3.2)

ED030845

ED030848

5/32

(4.0)

ED030846

ED030849

3/16

(4.8)

ED030847

ED030850

Manufactured in metric diameters, U.S. Customary sizes are approximate.

DEPOSIT COMPOSITION - As Required per AWS A5.1-91

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

%C

%Mn

%Si

%S

%P

 

 

 

Requirements

 

 

 

 

 

 

 

AWS E6010

Not Specified

 

 

 

 

 

 

 

 

 

 

 

 

Typical Results .10-.20

.40-.65

.11-.30 .009-.020

.005-.025

 

 

(3.2mm) (4.0mm) (4.8mm)

DC+ 65 - 130 90 - 175 140 - 225

NOTE: This AWS electrode classification is not required to deposit weld metal that is low in diffusible hydrogen. Therefore, these electrodes should not be used in applications where the hydrogen content of the weld metal is required to be controlled.

Pipeliner

8

www.lincolnelectric.com

Image 8
Contents Premium Pipe Welding Consumables Electric Company MIG Gmaw PSL1 PSL2Pipe Grades Wall thickness 3/4 in mmAPI 5L Pipe Grades Product Selection Root Pass Welding OnlyLow Hydrogen Stick Smaw Electrodes Consumable Selection GuideCellulosic All Position Stick Smaw Electrodes Outershield Gas-Shielded Flux-Cored FCAW-G Electrodes MIG Gmaw ElectrodesInnershield Self-Shielded Flux-Cored FCAW-S Electrodes Diameters / Packaging Typical Operating Procedures Welding Positions Advantage LincolnTypical Applications ConformanceWelding Positions Conformance Typical applications include high- yield pipe steelsMechanical Properties As Required per AWS A5.5-96 Deposit Composition As Required per AWS A5.5-96AWS A5.1 E7016 H4 Asme SFA-5.1 E7016 H4 Deposit Composition As Required per AWS A5.1-91Welding Positions Diameters / PackagingDiffusible Hydrogen AWS A5.5 E8018-G H4 Asme SFA-5.5 E8018-G H4AWS A5.18-2001 ER70S-G Asme SFA-5.18 ER70S-G Mechanical Properties As Required per AWS A5.182001Deposit Composition As Required per AWS A5.29-98 AWS A5.29-98 E71T8-K6 Asme SFA-5.29 E71T8-K6Mechanical Properties As Required per AWS A5.29-98 Consistently high CVN properties, even down to -40˚F -40˚C Deposit Composition As Required per AWS A5.29Welding Positions Shielding GAS 75-80% Ar / Balance CO2 Flow Rate 40-50 CFH 19-24 l/minMechanical Properties As Required per AWS A5.20-95 Deposit COMPOSITION-As Required per AWS A5.20-95All position wire designed to weld pipe up to Test Results Lincoln International Headquarters