Lincoln Electric 2HBG manual Welding Positions Shielding GAS

Page 15

PIPELINER G70M AWS E71T-1MJH8 & E71T-9MJH8 Gas-Shielded Flux-Cored (FCAW-G) Wire Electrode

Pipeliner G70M is designed to deliver outstanding weld properties for semi-automatic applications. Robust impacts mean consistently high CVN values.

ADVANTAGE LINCOLN

Impacts are typically in the 60 ft•lbf @ -20°F (-29°C), as-welded.

Smooth, spray type arc transfer and low spatter level.

Slag system provides for puddle support, good wetting and bead shape in all positions.

Manufactured under a quality system certified to ISO 9001 requirements.

Manufactured to actual lot control. Actual certificates of conformance are available upon request.

TYPICAL APPLICATIONS

All position single and multiple pass wire designed to join pipe up to X70.

WELDING POSITIONS

1G

2F

2G

4G

5G

3G

 

 

SHIELDING GAS

75-80% Ar / Balance CO2

Flow Rate 40-50 CFH (19-24 l/min.)

CONFORMANCE

AWS A5.20-95: E71T-1MJH8 E71T-9MJH8 ASME SFA-5.20: E71T-1MJH8 E71T-9MJH8

MECHANICAL PROPERTIES - As Required per AWS A5.20-95

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Charpy V-Notch

 

 

 

Yield Strength

Tensile Strength

Elongation

ft•lbf (Joules)

 

 

 

psi (MPa)

psi (MPa)

(%)

@ -40ºF (-40ºC)

 

 

 

 

 

 

 

 

 

 

 

Required

58,000 (400)

70,000

(480)

22

20

(27)

 

 

AWS E71T-1MJH8

min.

min.

min.

min.

 

 

& E71T-9MJH8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Typical Results

 

 

 

 

 

 

 

 

75% Ar / 25% CO2

80,000

89,000

26

78

(106)

 

 

 

(550)

(612)

 

 

 

 

NOTE: Pipeliner elec- trodes are manufactured under lot control. A Certificate of Test show- ing actual deposit chem- istry and mechanical properties per AWS A5.20 is available on request from the factory for every lot of electrode. (Fax 216-383-8386).

DIAMETERS / PACKAGING

 

 

 

 

 

 

 

 

 

 

 

 

 

Diameter

10 Lb. (4.5 kg)

25 Lb. (11 kg)

 

 

in.

(mm)

Plastic Spool

Plastic Spool

 

 

 

 

Foil Bag

Foil Bag

 

 

 

 

 

 

 

 

.045

(1.1)

ED030926

ED030927

 

DEPOSIT COMPOSITION-As Required per AWS A5.20-95

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

%C

%Mn

%P

%S

%Si

%Ni

 

Requirements

 

 

 

 

 

 

 

 

AWS E71T-1MJH8

.18

1.75

.03

.03

.90

.50

 

 

AWS E71T-9MJH8

max.

max.

max.

max.

max.

max.

 

 

 

 

 

 

 

 

 

 

Typical Results

 

 

 

 

 

 

 

 

75% Ar / 25% CO2

.05

1.60

.013

.011

.45

.36

 

TYPICAL OPERATING

PROCEDURES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Diameter

 

 

Parameters

 

.045 in. (1.1mm)

 

 

 

 

 

 

 

 

 

Polarity

 

 

 

DC+

 

CTWD(1) – in. (mm)

 

3/4 (19)

 

 

Wire Weight – lbs/in. (g/m)

 

.361/1000 (6.45)

 

 

Wire Feed Speed – in/min (m/min)

175-525 (4.4-13.3)

 

 

Arc Voltage (volts)

 

23-30

 

 

Approx. Current (amps)

 

130-275

 

 

Melt-off Rate – lbs/hr (kg/hr)

 

3.9-11.9 (1.8-5.4)

 

 

Deposition Rate – lbs/hr (kg/hr)

3.2-9.8 (1.4-4.4)

 

 

 

 

 

(1)

CTWD (Contact

 

DIFFUSIBLE HYDROGEN

 

 

Tip to Work

 

- As Required per AWS A5.20-95

 

 

 

Distance).

 

 

 

 

 

 

Subtract 1/4" to

 

 

 

 

 

 

 

 

 

 

 

 

calculate Electrical

 

(mL/100g

 

 

 

 

 

 

 

Stickout.

 

weld deposit)

 

 

 

 

 

 

 

 

 

 

Requirements

 

 

 

 

 

 

 

E71T-1MJH8

8

 

 

 

 

 

 

& E71T-9MJH8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Typical Results

4 - 8

75-80% Ar/CO2

 

Pipeliner

15

www.lincolnelectric.com

Image 15
Contents Premium Pipe Welding Consumables Electric Company MIG Gmaw Wall thickness 3/4 in mm PSL1PSL2 Pipe GradesProduct Selection Root Pass Welding Only API 5L Pipe GradesConsumable Selection Guide Cellulosic All Position Stick Smaw ElectrodesLow Hydrogen Stick Smaw Electrodes MIG Gmaw Electrodes Innershield Self-Shielded Flux-Cored FCAW-S ElectrodesOutershield Gas-Shielded Flux-Cored FCAW-G Electrodes Conformance Diameters / Packaging Typical Operating ProceduresWelding Positions Advantage Lincoln Typical ApplicationsDeposit Composition As Required per AWS A5.5-96 Welding Positions ConformanceTypical applications include high- yield pipe steels Mechanical Properties As Required per AWS A5.5-96Deposit Composition As Required per AWS A5.1-91 AWS A5.1 E7016 H4 Asme SFA-5.1 E7016 H4AWS A5.5 E8018-G H4 Asme SFA-5.5 E8018-G H4 Welding PositionsDiameters / Packaging Diffusible HydrogenMechanical Properties As Required per AWS A5.182001 AWS A5.18-2001 ER70S-G Asme SFA-5.18 ER70S-GAWS A5.29-98 E71T8-K6 Asme SFA-5.29 E71T8-K6 Mechanical Properties As Required per AWS A5.29-98Deposit Composition As Required per AWS A5.29-98 Deposit Composition As Required per AWS A5.29 Consistently high CVN properties, even down to -40˚F -40˚CDeposit COMPOSITION-As Required per AWS A5.20-95 Welding Positions Shielding GAS75-80% Ar / Balance CO2 Flow Rate 40-50 CFH 19-24 l/min Mechanical Properties As Required per AWS A5.20-95All position wire designed to weld pipe up to Test Results Lincoln International Headquarters