Lincoln Electric 10475, 10473, 10476, 10474 manual Routine Maintenance, Periodic Maintenance

Page 22

D-2

MAINTENANCE

D-2

 

 

 

ROUTINE MAINTENANCE

1.Keep the cutting or gouging area and the area around the machine clean and free of combustible materials. No debris should be allowed to collect which could obstruct air flow to the machine.

2.Every 6 months or so, the machine should be cleaned with a low pressure airstream. Keeping the machine clean will result in cooler operation and higher reliability. Be sure to clean these areas:

-Power, Output and Control printed circuit boards and heat sinks

-Power switch

-Main Transformer

-Input Rectifier

3.Examine the sheet metal case for dents or break- age. Repair the case as required. Keep the case in good condition to insure that high voltage parts are protected and correct spacings are maintained. All external sheet metal screws must be in place to insure case strength and electrical ground continu- ity.

4.Check the air regulator filter to be sure it does not become clogged. The air filter on the machine is self draining and will not have to be emptied.

5.Check the filter element every several months to see if it is clogged (weekly in very dirty environ- ments). Replace if necessary by first removing the two screws that attach the filter cage to the back panel assembly, then slide the cage away from the back of the machine and remove. Next, twist the clear filter bowl until it comes off (be careful not to lose the o-ring seated at the top of the bowl threads). Unscrew the filter element and replace with new element. Assemble parts in reverse order as described above.

6.Inspect the cable periodically for any slits or punc- ture marks in the cable jacket. Replace if neces- sary. Check to make sure that nothing is crushing the cable and blocking the flow of air through the air tube inside. Also, check for kinks in the cable periodically and relieve any so as not to restrict the flow of air to the torch.

PERIODIC MAINTENANCE

WARNING

ELECTRIC SHOCK CAN KILL.

• Turn off machine at the disconnect switch on the front of the machine before tightening, cleaning or replacing consumables.

----------------------------------------------------------------------------

Change consumables as required.

1. Thermal Protection

Two thermostats protect the machine from excessive operating temperatures. Excessive temperatures may be caused by a lack of cooling air or operating the machine beyond the duty cycle and output rating. If excessive operating temperatures should occur, the yellow thermal LED will light and the thermostat will prevent output voltage or current.

Thermostats are self-resetting once the machine cools sufficiently. If the thermostat shutdown was caused by excessive output or duty cycle and the fan is operating normally, the Power Switch may be left on and the reset should occur within a 15 minute period. If the fan is not turning or the air intake louvers were obstructed, then the power must be switched off and the fan prob- lem or air obstruction must be corrected.

2.Filter Capacitor Conditioning (Pro-Cut 55, 400-460 VAC only)

A protection circuit is included to monitor the voltage across filter capacitors C1 and C2. In the event that the capacitor voltage is too high, the protection circuit will prevent output. The protection circuit may prevent output providing all these circumstances are met:

a.Machine is connected for 400-460 VAC input.

b.Machine did not have power applied for many months.

c.Machine will not produce output when power is first switched on.

If these circumstances apply, the proper action is to switch the machine on and let it idle for up to 30 min- utes. This is required to condition the filter capacitors after an extended storage time. The protection circuit will automatically reset once the capacitor conditioning and resultant voltage levels are acceptable. It may be necessary to turn the power switch off and back on again after this period.

PRO-CUT 55

Image 22
Contents PRO-CUT TM Safety Plasma Cutting or Gouging can be hazardousPlasma ARC can injure Iii Précautions DE Sûreté Sûreté Pour Soudage a L’ArcThank You Please Examine Carton and Equipment For Damage ImmediatelyTable of Contents Section E ViiSection D Section FTechnical Specifications PRO-CUT Installation1Ø Input Current at Rated Output Select Proper Location Safety Precautions Electric Shock can KillHigh Frequency Interference Protection Input Electrical Connections Input Power Cord Connector InstallationFrame Grounding Output Connections GAS Input ConnectionsTorch Connection Operation Safety PrecautionsPreheat Temperature for Plasma Cutting DescriptionUser Responsibility Operational Features and ControlsDesign Features Advantages Recommended Processes and EquipmentCutting Capability Consumable LifeControls and Settings LimitationsElectric Shock can Kill Do not use pliers or over tightenGeneral In All Cases Procedure RecommendationsPilot ARC Discussion Thin Gauge Sheet MetalSuggestions for Extra Utility from the PRO-CUT System Accessories General Options AccessoriesInput Filter Capacitor Discharge Procedure MaintenanceElectric Shock can kill Routine Maintenance Periodic MaintenanceTroubleshooting HOW to USE Troubleshooting GuideTroubleshooting Your local Lincoln Authorized Field Service Facility Page Or dross Symptom Check Wiring Diagram PRO-CUT 55 for Codes 10473 Diagrams Dimension Print PRO-CUT DiagramsPRO-CUT Precaucion Warnung

10476, 10474, 10473, 10475 specifications

Lincoln Electric is renowned for its commitment to quality in arc welding equipment, and its models 10475, 10473, 10474, and 10476 are no exceptions. These products showcase advanced technologies designed to enhance user experience and improve weld quality across various applications.

The Lincoln Electric 10475 is a premier choice for professionals seeking exceptional portability and efficiency in stick welding. This model features a lightweight design that makes it easily transportable, ideal for fieldwork. It boasts a robust output range, allowing it to handle various electrode sizes, making it versatile for different metal types. The 10475 also incorporates a built-in electronic device that reduces the chance of arc blow, ensuring a stable arc when welding in challenging environments.

The 10473 model stands out for its innovative inverter technology, which significantly enhances energy efficiency. This unit reduces power consumption without sacrificing performance, making it an environmentally conscious choice for industrial applications. It features an intuitive interface, allowing users to adjust settings easily and quickly. The 10473 is designed to support TIG and stick welding with smooth arc control, promoting consistent welds and minimal spatter.

Model 10474 continues the trend of advanced technology with its synergic control feature, which automatically adjusts welding parameters based on the material and thickness. This functionality takes the guesswork out of settings, making it user-friendly for both beginners and seasoned welders. Additionally, the 10474 is equipped with a fan-on-demand system, reducing noise and improving energy efficiency while ensuring optimal cooling during extensive use.

Lastly, the 10476 model excels in dual function capabilities, providing users with the option for both MIG and flux-cored welding. This flexibility expands the range of applications, from thin sheet metal to thick structures. The 10476 also integrates a high duty cycle, making it suitable for continuous operation on demanding projects. Features such as advanced digital displays support precise control over voltage and wire feed speed, ensuring high-quality results.

Together, these Lincoln Electric models reflect the company's dedication to innovation and excellence in welding technologies. Their unique features cater to a wide array of welding needs, making them essential tools for professionals across various industries. Whether for portability, efficiency, user-friendliness, or versatility, Lincoln Electric continues to set the standard in welding equipment.