Lincoln Electric 10708 manual Weld Output Terminals with Flange NUT, PIN Amphenol, Engine Controls

Page 19

B-3

OPERATION

B-3

 

 

 

It acts as an inductance control. The proper setting depends on the procedure and operator preference. Start with a setting at 0.

5.WELD OUTPUT TERMINALS WITH FLANGE NUT:

Provides a connection point for the electrode and work cables.

6. GROUND STUD: (graphic)

Provides a connection point for connecting the machine case to earth ground for the safest grounding procedure.

7. 14 PIN AMPHENOL:

For attaching wire feeder control cables to the RANGER 305G. Includes contactor closure circuit , auto-sensing remote control circuit, and 120V and 42V power. The remote control circuit operates the same as the 6 Pin Amphenol.

8. 6 PIN AMPHENOL:

For attaching optional remote control equipment. When in the CC-STICK, PIPE, and CV-WIRE modes and when a remote control is connected to the Amphenol, the auto-sensing circuit in the RANGER 305G automatically switches the OUTPUT control from control at the welder to remote control .

When using the TOUCH START TIG mode with a TIG Module connected to the RANGER 305G, the OUT- PUT control on the front of the RANGER 305G is used to set the maximum current range of the CUR- RENT CONTROL on the TIG Module.

9. WELD TERMINALS CONTROL SWITCH:

In the WELD TERMINALS ON position, the output is electrically hot all the time. In the REMOTELY CON- TROLLED position, the output is controlled by a wire feeder or amptrol device, and is electrically off until a remote switch is depressed.

10. WIRE FEEDER VOLTMETER SWITCH:

13. START PUSH BUTTON - Energizes the

starter motor to crank the engine.

14.IDLER SWITCH- Has two positions as follows:

1)In the HIGH position, the engine runs at the high idle speed controlled by the engine governor.

2)In the AUTO position, the idler operates as follows:

When switched from HIGH to AUTO or after start- ing the engine, the engine will operate at full speed for approximately 12 seconds and then go to low idle speed.

When the electrode touches the work or power is drawn for lights or tools (approximately 100 Watts minimum), the engine accelerates and operates at full speed.

When welding ceases or the AC power load is

turned off, a fixed time delay of approximately 12 seconds starts. If the welding or AC power l o a d is not restarted before the end of the time delay, the idler reduces the engine speed to low idle speed.

The engine will automatically return to high idle speed when there is welding load or AC power load reapplied.

15.ENGINE ALTERNATOR TROUBLE LIGHT-The engine alternator light is off when battery

charging system is functioning normally. If light turns on, the alternator or the voltage regulator may not be operating correctly. The light may also come on due to the battery not holding a charge. It is normal for the light to come on while starting the engine.

16.ENGINE HOUR METER – Displays the total time that the engine has been running. This meter is useful for scheduling prescribed maintenance.

STARTING AND STOPPING

THE ENGINE

Matches the polarity of the wire feeder voltmeter to the polarity of the electrode.

ENGINE CONTROLS:

11.RUN/STOP SWITCH - RUN position ener- gizes the engine prior to starting. STOP position stops the engine. The oil pressure interlock switch prevents battery drain if the switch is left in the RUN position and the engine is not operating.

12.CHOKE - When pulled out, it closes the choke valve on the engine carburetor for quick starting.

Remove all plugs connected to the AC power receptacles.

Set IDLER switch to AUTO.

Set the RUN/STOP switch to RUN.

Pull the choke to the full out position.

Press and hold the engine START button until the engine starts.

Release the engine START button when the engine starts.

Push the choke back in.

RANGER 305G

Image 19
Contents Ranger 305 G Safety Depends on YouSafety Electric Shock can kill Cylinder may explode if damaged Précautions DE Sûreté Thank You Table of Contents Vii Installation Machine Specifications Ranger 305G K1726-1 Safety Precautions PRE-OPERATION Engine Service Electrical Connections Auxiliary Power Receptacles Connection of Ranger 305G to Premises Wiring Connection of an LN-23P Wire Feeder to the Ranger 305G Connection of Lincoln Electric Wire FeedersADD Fuel Safety PrecautionsFor Auxiliary Power Engine OperationARC Control Weld Mode Selector SwitchWelding Controls Digital Output MetersPIN Amphenol Weld Terminals Control SwitchWire Feeder Voltmeter Switch Weld Output Terminals with Flange NUTWelder Operation StoppingTypical Ranger 305G Fuel Consumption Typical Current Ranges 1 for Tungsten ELECTRODES2 Wire WELDING-CVTIG Welding ARC Gouging Auxiliary PowerRanger 305G Extension Cord Length Recommendations T12153-9 50 AMP, 120/240 V Power Plug AccessoriesMake and Part Number FrequencyKohler CH22 Engine Engine Oil Change Engine Oil Refill Capacities Without oil filter replacementAir Cleaner Service Air Pre-cleaner ServiceAIR Filter Paper Element Spark PlugChecking the Electrolyte Level Cleaning the BatteryCharging the Battery Overspeed is HazardousWelder/Generator Maintenance Troubleshooting Contact your local Lincoln Authorized Field Service Facility Is Evident.Authorized Field Service FacilityWelding without a control cable Contact your local Lincoln Authorized Field Service FacilityStick Diagrams Diagrams Diagrams Diagrams Diagrams S24787-6 Engine Welders /LN-8 Connection DiagramDiagrams Diagrams Diagrams Diagrams Diagrams G3743 16.75 23.50Ranger 305G Precaucion Warnung