2.2.3 MOTOR

1.Disconnect the unit from the power source.

2.Remove the front grille. (Refer to Section 2.1.1)

3.Remove the cabinet. (Refer to Section 2.1.2)

4.Remove the control panel. (Refer to Section 2.1.3)

5.Remove the upper air guide . (Refer to Section 2.2.1)

6.Remove the compressor, turbo fan, fan and shroud. (Refer to Section 2.2.2)

7.Remove 2 screws that secure the motor to the motor mount . (See Figure 10)

8.Remove the motor.

9.Re-install by referring to the procedures above.

2.2.4 AIR GUIDE

1.Disconnect the unit from the power source.

2.Remove the front grille. (Refer to Section 2.1.1)

3.Remove the cabinet. (Refer to Section 2.1.2)

4.Remove the control panel. (Refer to Section 2.1.3)

5.Remove the upper air guide . (Refer to Section 2.2.1)

6.Remove the compressor, turbo fan, fan and shroud. (Refer to Section 2.2.2)

7.Remove the motor. (Refer to Section 2.2.3)

8.Remove 2 screws that secure the air guide to the base pan. (See Figure 11)

9.Push the air guide backward and lift it upward. (See Figure 11)

10.Re-install by referring to the procedures above.

2.3ELECTRICAL PARTS

2.3.1 OVERLOAD PROTECTOR

1.Remove the front grille and cabinet. (Refer to Section 2.1)

2.Remove the nut which fastens the terminal cover.

3.Remove the terminal cover.

4.Remove all the leads from the overload protector.

5.Remove the overload protector.

6.Re-install the components by referring to the removal procedure above.

(See Figure 12 and 13)

Figure 10

Figure 11

Figure 12

Figure 13

 

— 7—

Image 7
Contents Page Contents Preface Locations of Controls Cabinet Disassembly InstructionsMechanical Parts Front GrilleAIR Guide Upper AIR Handling PartsORIFICE, Turbo FAN and FAN AIR Guide Electrical PartsOverload Protector Thermostat Rotary SwitchCompressor CapacitorRefrigeration System Power CordCondenser Capillary Tube EvaporatorPulling Vacuum Troubleshooting Guide Condenser Coils Piping SystemUnit is running but cooling is ineffective Troubleshooting GuideFails to Start Room AIR Conditioner Voltage Limits Replace if open. If the compressor temperature is Complaint Cause Remedy Model ZQ05C10 Circuit DiagramExploded View Service Parts List Memo Memo Use Factory Certified Parts

ZQ05C10 specifications

The Friedrich ZQ05C10 is an innovative solution in the world of air conditioning, specifically designed to meet the needs of modern consumers and businesses seeking efficient and effective climate control. This model stands out with its combination of performance, technology, and user-friendly features, making it a popular choice among users.

One of the main features of the ZQ05C10 is its energy efficiency. This model operates with a high SEER (Seasonal Energy Efficiency Ratio) rating, which indicates its ability to provide cooling while consuming less electricity. This not only helps in reducing energy bills but also contributes to a more sustainable environment by lowering the carbon footprint.

The ZQ05C10 is equipped with advanced inverter technology, allowing it to adjust its cooling output according to the ambient temperature. This smart feature enables the unit to run more quietly and efficiently, maintaining a comfortable indoor climate without the noisy fluctuations associated with traditional air conditioning units.

Another standout characteristic of the Friedrich ZQ05C10 is its robust build quality and sleek design. The unit boasts a modern aesthetic that can seamlessly fit into any home or office decor. Available in a range of sizes, it can be installed in various settings, from small bedrooms to larger living spaces.

In terms of technological integration, the ZQ05C10 comes with Wi-Fi connectivity, allowing users to control their air conditioning remotely via a smartphone application. This feature enhances usability, enabling users to adjust settings, monitor energy consumption, and schedule operations from virtually anywhere.

Moreover, the ZQ05C10 incorporates advanced filtration systems that significantly improve indoor air quality. Its multi-stage filters capture dust, allergens, and other airborne particles, ensuring that the air circulated within the space is clean and healthy.

Safety features are also prioritized in the design of the ZQ05C10. It includes built-in protection against power surges and has an auto-restart function in the event of a power failure, ensuring that it resumes operation without any manual intervention.

In summary, the Friedrich ZQ05C10 presents a comprehensive package featuring energy efficiency, advanced technology, robust design, and enhanced air quality. Its combination of these traits makes it an excellent choice for anyone looking to invest in a reliable air conditioning system.