Friedrich CP14N10, CP18N30, CP24N30 manual Replace fuse, reset breaker. If repeats, check fuse

Page 14

Cooling Only Room Air Conditioners: Troubleshooting Tips

Problem

 

Possible Cause

Action

 

 

 

Replace fuse, reset breaker. If repeats, check fuse

 

Fuse blown or circuit tripped

or breaker size. Check for shorts in unit wiring &

 

 

 

components

 

 

 

Unit does not run

Power cord not plugged in

Plug it in

System switch in

"OFF" position

Set switch correctly

 

 

Inoperative system switch

Test for continuity in each switch position

 

Loose or disconnected wiring at switch or other

Check wiring & connections. Reconnect per wiring

 

components

 

diagram

Problem

Possible Cause

Action

 

Dirty filter

Clean as recommended in Owner's Manual

 

Restricted airflow

Check for dirty or obstructed coil. Use pressure

 

wash or biodegradable cleaning agent to clean

 

 

Evaporator coil

Inoperative t-stat

Test for shorted t-stat or stuck contacts

Short of refrigerant

De-ice coil & check for leak

freezes up

Inoperative fan motor

Test fan motor & replace if inoperative

 

 

 

De-ice coil. Check temp. differential (delta T) across

 

Partially restricted capillary tube

coil. Touch test coil return bends for same temp.

 

 

Test for low running current

 

 

 

Problem

Possible Cause

Action

 

Excessive heat load

Unit undersized. Test cooling performance & replace

 

with larger unit if needed

 

 

 

Restriction in line

Check for partially iced coil & check temperature

 

split across coil

Compressor runs

 

 

Check for oil at silver soldered connections. Check

continually & does not

 

Refrigerant leak

for partially iced coil. Check split across coil. Check

cycle off

 

for low running amperage

 

 

 

 

 

 

T-stat contacts stuck

Check operation of t-stat. Replace if contacts

 

remain closed.

 

 

 

T-stat incorrectly wired

Refer to appropriate wiring diagram

Problem

Possible Cause

Action

 

T-stat contacts stuck

Disconnect power to unit. Remove cover of t-stat &

 

check if contacts are stuck. If so, replace t-stat

 

 

T-stat does not turn

 

 

T-stat set at coldest point

Turn to higher temp. setting to see if unit cycles off

unit off

 

 

 

Incorrect wiring

Refer to appropriate wiring diagrams

 

Unit undersized for area to be cooled

Refer to industry standard sizing chart

 

 

 

14

Image 14
Contents Service & Parts Manual Table of Contents Specifications and Technical Parameters Performance DataOuter Component Identification Models CP14N10, CP18N30, CP24N30Installation Dimensions Wiring Diagrams Functional Component Definitions Mechanical ComponentsRefrigeration System Sequence of Operation Refrigerant System ComponentsSealed Refrigeration System Repairs Equipment RequiredRefrigerant Charging Method of ChargingUndercharged Refrigerant Systems Restricted Refrigerant System Cooling Only Room Air Conditioners Troubleshooting Tips Problem Possible Cause ActionReplace fuse, reset breaker. If repeats, check fuse Overload inoperative. Opens too soon Surfaces Heat / Cool Room Air Conditioners Troubleshooting Tips Switch unit several times from heating to cooling Components Model CP14N10 No Description Qty Friedrich Part# CodeModel CP14N10 Models CP18C30 & CP18N30 Description Qty Friedrich Part# CodeFront Clapboard of Snail Shell Model CP24N30 Model CP24N30 Model CP24N30 Room AIR Conditioners Limited Warranty CP-14-18-24-Svc-Prts-07
Related manuals
Manual 28 pages 21.43 Kb

CP14N10, CP18N30, CP24N30 specifications

The Friedrich CP24N30, CP18N30, and CP14N10 are a trio of innovative portable air conditioning units designed to provide optimal comfort in residential and commercial settings. Each model boasts distinct features tailored to various room sizes, ensuring efficient temperature management.

Starting with the Friedrich CP24N30, this unit is engineered for larger spaces, able to cool areas up to 1,500 square feet. Its powerful cooling capacity of 24,000 BTUs allows it to quickly lower temperatures even in challenging environments. This model incorporates advanced inverter technology, which enhances energy efficiency by adjusting its cooling output according to the current temperature. Furthermore, the CP24N30 is equipped with a robust dehumidification function, capable of removing excess moisture from the air, making it ideal for humid climates. Its user-friendly interface, remote control, and Wi-Fi capability allow for convenient operation from anywhere in the home.

The Friedrich CP18N30 is a versatile choice for medium-sized rooms, covering up to 1,100 square feet with its 18,000 BTU cooling capacity. Like its larger counterpart, it features inverter technology, which not only saves energy but also results in quieter operation, a crucial factor for those who prioritize peace and tranquility in their living spaces. The CP18N30 also has a high EER (Energy Efficiency Ratio), making it a cost-effective option for cooling. Its built-in timer, along with programmable settings, enables homeowners to schedule operation according to their lifestyle, ensuring cooling is available when it is most required.

Lastly, the Friedrich CP14N10 is designed for smaller rooms, offering a cooling capacity of 14,000 BTUs and catering to areas up to 600 square feet. This unit balances performance and size, making it an excellent option for apartments and smaller living spaces. The CP14N10 maintains the brand's commitment to efficiency with its inverter technology that minimizes energy usage while maximizing cooling output. Like the other models, it includes a dehumidification setting, enhancing indoor air quality by alleviating humidity levels.

In all three models, Friedrich integrates smart technologies such as fault diagnosis and self-cleaning capabilities, ensuring reliability and ease of maintenance. Additionally, they come equipped with washable filters, promoting long-term efficiency and cleaner air. With their varying cooling capacities, these units offer tailored solutions for a wide array of environments while emphasizing energy efficiency and user convenience.