Craftsman 919.724572 owner manual Know Your Air Compressor, Description of Operation

Page 12

OPERATION

Know Your Air Compressor

READ THIS OWNER’S MANUAL AND SAFETY RULES BEFORE OPERATING YOUR UNIT. Compare the illustrations with your unit to familiarize yourself with the location of various controls and adjustments. Save this manual for future reference.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Outlet

 

 

 

 

 

 

 

 

 

 

Pressure

 

 

 

 

 

 

 

 

 

 

Gauge

 

 

 

 

On/Auto/Off

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Switch

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pressure

 

 

 

Quick

 

 

 

 

Switch

 

 

 

 

Connect

 

 

 

 

 

 

 

 

 

 

 

 

 

Tank

 

 

 

 

 

 

 

 

 

 

 

Regulator

 

 

 

 

Pressure Gauge

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Safety Valve

 

 

Description of Operation

Become familiar with these controls before operating the unit. On/Auto/Off Switch: Turn this switch ON to provide automatic power to the pressure switch and OFF to remove power at the end of each use.

Pressure Switch: The pressure switch automatically starts the motor when the air tank pressure drops below the factory set "cut-in” pressure. It stops the motor when the air tank pressure reaches the factory set "cut-out” pressure.

Safety Valve: If the pressure switch does not shut off the air compressor at its "cut-out” pressure setting, the safety valve will protect against high pressure by "popping out” at its factory set pressure (slightly higher than the pressure switch "cut-out” setting).

Outlet Pressure Gauge: The outlet pressure gauge indicates the air pressure available at the outlet side of the regulator. This pressure is controlled by the regulator and is always less than or equal to the tank pressure.

Tank Pressure Gauge: The tank pressure gauge indicates the reserve air pressure in the tank.

Regulator: Controls the air pressure shown on the outlet pressure gauge. Pull the knob out and turn clockwise to increase pressure and counterclockwise to decrease pressure. When the desired pressure is reached push knob in to lock in place.

Drain Valve: The drain valve is located at the base of the air tank and is used to drain condensation at the end of each use.

Drain

Valve

Cooling System (not shown): This compressor contains an advanced design cooling system. At the heart of this cooling system is an engineered fan. It is perfectly normal for this fan to blow air through the vent holes in large amounts. You know that the cooling system is working when air is being expelled.

D27446

12- ENG

Image 12
Contents AIR Compressor Sold by Sears Canada, Inc. Toronto, Ont. M5B 2B8Table of Contents Specification Chart Safety Guidelines DefinitionsImportant Safety Instructions Hazard What Could HappenWhat can Happen Hazard When Transporting Compressor Result in serious burnsNever operate the compressor with Belt can cause serious injury if theyHazard Accessories AccessoriesGlossary Duty CycleInstallation Location of the Air CompressorRisk of Electrical Improper Grounding can Result in Electrical ShockExtension Cords Voltage and Circuit ProtectionOperation Know Your Air CompressorDescription of Operation How to Stop Before First Start-upCheck Valve Quick Connect On/Auto Off Lever RegulatorHow to Start Before Each Start-UpMaintenance To Check Safety ValveCustomer Responsibilities To Drain TankService and Adjustments To Replace or Clean Check ValveHose Clamp To Replace Regulator Outlet Pressure Gauge Regulator Quick ConnectNipple Regulator ArrowStorage Troubleshooting Problem Cause CorrectionPressure reading Check wiring connection Table DES Matières Sears Canada, Inc., Toronto, Ont. M5B 2B8Tableau DES Spécifications Mesures DE Sécurité DéfinitionsConsignes DE Sécurité Importantes Risque DE Choc Électrique Risque PAR InhalationRisque DE Brûlures Risque Relié AUX Pièces MobilesRisque DE Chute Risque Dune Utilisation Dangereuse Accessoires Cycle DE ServiceAccessoires LexiqueInstalación Ubicación del compresor de aireInstrucciones Para Conectar a Tierra EnchufeRallonges Protection contre la surtension et Protection du circuitUtilisation Familiarisez-vous avec votre compresseur dairDescription du fonctionnement Utilisation de lappareil Arrêt de lappareilAvant le démarrage Pompe du compresseur dair non illustréeAvant chaque mise en marche Mise en marcheEntretien Responsabilités du clientVérification de la soupape de sûreté Vidange du réservoirRemplacement ou nettoyage de la soupape de retenue Entretien ET RéglagesCollier du boyau Remplacement du régulateur Mano- mètre de sortie Régulateur Raccord à connexion rapideEmbout Régulateur FlècheRangement Dépannage Problème Cause CorrectionSerrer Peut éclater ou exploserConsidérée normale Fusible sauté ou coupe-circuit Get it fixed, at your home or ours