Craftsman 919.724572 owner manual Check wiring connection

Page 21

PROBLEM

CAUSE

CORRECTION

Regulator will

Damaged regulator.

Replace.

not shut off air

 

 

outlet.

 

 

 

 

 

Motor will not

Motor overload protection

Let motor cool off and

run.

switch has tripped.

overload switch will

 

 

automatically reset.

 

Tank pressure exceeds

Motor will start automatically

 

pressure switch "cut-in"

when tank pressure drops

 

pressure.

below "cut-in" pressure of

 

 

pressure switch.

 

Extension cord is wrong

Check for proper gauge wire

 

length or gauge.

and cord length.

 

Check valve stuck open.

Remove and clean, or

 

 

replace.

 

Loose electrical connections.

Check wiring connection

 

 

inside pressure switch and

 

 

terminal box area.

 

Possible defective motor or

Have checked by a Trained

 

starting capacitor.

Service Technician.

 

Paint spray on internal motor

Have checked by a Trained

 

parts.

Service Technician. Do not

 

 

operate the compressor in

 

 

the paint spray area. See

 

 

flammable vapor warning.

 

Pressure release valve on

Bleed the line by pushing the

 

pressure switch has not

lever on the pressure switch

 

unloaded head pressure.

to the "off" position; if the

 

 

valve does not open, replace

 

 

switch.

 

Fuse blown, circuit breaker

1. Check fuse box for blown

 

tripped.

fuse and replace as

 

 

necessary. Reset circuit

 

 

breaker. Do not use a fuse

 

 

or circuit breaker with

 

 

higher rating than that

 

 

specified for your particular

 

 

branch circuit.

 

 

2. Check for proper fuse. You

 

 

should use a time delay

 

 

fuse.

 

 

3. Check for low voltage

 

 

conditions and/or proper

 

 

extension cord.

 

 

4. Disconnect the other

 

 

electrical appliances from

 

 

circuit or operate the

 

 

compressor on its own

 

 

branch circuit.

 

 

 

21- ENG

D27446

Image 21
Contents Sold by Sears Canada, Inc. Toronto, Ont. M5B 2B8 AIR CompressorTable of Contents Specification Chart Safety Guidelines DefinitionsImportant Safety Instructions What Could Happen HazardWhat can Happen Hazard Result in serious burns When Transporting CompressorNever operate the compressor with Belt can cause serious injury if theyHazard Accessories AccessoriesGlossary Duty CycleLocation of the Air Compressor InstallationRisk of Electrical Improper Grounding can Result in Electrical ShockVoltage and Circuit Protection Extension CordsOperation Know Your Air CompressorDescription of Operation Before First Start-up How to StopCheck Valve Quick Connect On/Auto Off Lever RegulatorBefore Each Start-Up How to StartTo Check Safety Valve MaintenanceCustomer Responsibilities To Drain TankService and Adjustments To Replace or Clean Check ValveHose Clamp Outlet Pressure Gauge Regulator Quick Connect To Replace RegulatorNipple Regulator ArrowStorage Problem Cause Correction TroubleshootingPressure reading Check wiring connection Sears Canada, Inc., Toronto, Ont. M5B 2B8 Table DES MatièresTableau DES Spécifications Mesures DE Sécurité DéfinitionsConsignes DE Sécurité Importantes Risque PAR Inhalation Risque DE Choc ÉlectriqueRisque DE Brûlures Risque Relié AUX Pièces MobilesRisque DE Chute Risque Dune Utilisation Dangereuse Cycle DE Service AccessoiresAccessoires LexiqueUbicación del compresor de aire InstalaciónInstrucciones Para Conectar a Tierra EnchufeProtection contre la surtension et Protection du circuit RallongesUtilisation Familiarisez-vous avec votre compresseur dairDescription du fonctionnement Arrêt de lappareil Utilisation de lappareilAvant le démarrage Pompe du compresseur dair non illustréeMise en marche Avant chaque mise en marcheResponsabilités du client EntretienVérification de la soupape de sûreté Vidange du réservoirRemplacement ou nettoyage de la soupape de retenue Entretien ET RéglagesCollier du boyau Mano- mètre de sortie Régulateur Raccord à connexion rapide Remplacement du régulateurEmbout Régulateur FlècheRangement Problème Cause Correction DépannageSerrer Peut éclater ou exploserConsidérée normale Fusible sauté ou coupe-circuit Get it fixed, at your home or ours