Craftsman 921.16642 Operating Procedures, DaiJy Start=Up Procedures, DaiJy Shut=Down Procedures

Page 7

Operating Procedures

DaiJy Start=Up Procedures

1.Set the Auto-On/Off switch to the Off position.

2.Inspect the air compressor, air hose, and any accessories/tools being used for damage or obstruction. If any of these mentioned items are in need of repair/ replacement, contact your local authorized dealer before use.

3.Close the drain valve.

4.Connect the air hose to the quick connect socket on the regulator assembly by inserting the quick connect plug on the air hose into the quick connect socket. The quick connect socket collar will snap forward and lock the plug into place providing an air tight seal between the socket and plug. To release the air hose push the collar back on the quick connect socket.

5.Plug the power cord into the proper receptacle.

6.Turn the Auto-On/Off switch to the On-Auto position and the compressor will start and build air pressure in the tank to cut-out pressure and then shut off automatically.

7.Adjust the regulator to a PSi setting that is needed for your application and be sure it is within the safety standards required to perform the task. If using a pneumatic tool, the manufacturer should have recommendations in the manual for that particular tool on operating PSi settings.

8.The air compressor is now ready for use. The following inflation and cleaning accessories packaged with this unit should only be operated at maximum pressure

of 90PSI: Blow gun, adapter and inflation needle.

®

®

DaiJy Shut=Down Procedures

1.Set the Auto-On/Off switch to the Off position.

2.Unplug the power cord from the receptacle.

3.Set the outlet pressure to zero on the regulator.

4.Remove any air tools or accessories.

5.Open the drain valve allowing air to bleed from the tank. After all of the air has bled from the tank, close the drain valve to prevent debris buildup in the valve.

When draining the tank, always use ear and eye protection. Drain the tank in a suitable location; condensation will be present in most cases of draining.

Water that remains in the tank during storage will corrode and weaken the air tank which could cause the tank to

rupture. To avoid serious injury, be sure to drain the tank after each use or daily.

Image 7
Contents Crafts Contents Risk of Falling Risk from Flying Objects Safety SymbolsImportant Safety Instructions and Guidelines Risk of Burns Risk Electrical Shock Explosion or Fire Risk of Bursting Specifications Glossary Duty CycleTank Drain Valve Parts FeaturesRegulator Air intake Filter Tank Pressure GaugeGetting Started Location of the Air Compressor Installation & AssemblyGrounding Instructions DaiJy Start=Up Procedures Operating ProceduresDaiJy Shut=Down Procedures Storage MaintenanceBefore Each use Items to Check/Change Or daily Problem Troubleshooting GuideAir Compressor Model 921.166420 Exploded View Air Compressor Model Parts List Page CRRFT3MRIi Contenido Riesgo de caida Simbolos comunes de seguridadNstrucciones y pautas de seguridad importantes Guarde todas las instruccionesGlosario EspecificacionesCiclo de trabajo Tubo de Partes y caracteristicasProcedimiento inicial de preparaci6n Instalacibn y ensamblajeRiesgo de incendio o explosi6n Instrucciones de conexi6n a tierraProcedimiento diario de arranque Procedirnientos de operaci6nAlmacenamiento MantenimientoDiagnbstico y correccibn de fallas ProblemaCompresor de aire- Modelo 921.166420 Vista esquemtica Compresor de aire- Modelo Lista de las piezas 921.166420 MY-HOME Callanytime,day or nightU.S.A.and Canada Your Home