Craftsman 921.16638 operating instructions Troubleshooting Guide

Page 9

Troubleshooting Guide

The air compressor should be turned off and unplugged from the power source before any maintenance is performed as well as the air bled from the tank and the unit allowed time to cool, Personal injuries could occur from moving parts, electrical sources, compressed air, or hot surfaces,

PROBLEM

Air leaks at the check valve or at the pressure relief valve,

Air leaks between head and cylinder,

Air leak from safety valve,

Pressure reading on the regulated pressure gauge drops when an accessory is used,

POSSIBLE CORRECTION

A defective check valve results in a constant air leak at the pressure relief valve when there is pressure in the tank and the compressor is shut off, Drain the tank, then remove and clean or replace the check valve,

Be sure of proper torque on head bolts, if leak remains, contact a service technician,

Operate the safety valve manually by pulling on the ring, if the valve continues to leak when in the closed position, it should be replaced,

if there is an excessive amount of pressure drop when the accessory is used, replace the regulator,

NOTE:

Adjust the regulated pressure under flow conditions (while accessory is being used), it is normal for the gauge to show minimal pressure loss during initial use of the tool,

Excessive tank pressure,

Motor wiii not start,

Excessive moisture in the discharge air,

Move the Auto-On/Off lever to the Off position, if the unit doesn't shut off, unplug it from the power source and contact a service technician,

Make sure power cord is plugged in and the switch is on, inspect for the proper size fuse in your circuit box, if the fuse was tripped, reset it and restart the unit, if repeated tripping occurs, replace the check valve or contact a service technician,

Remove the water in the tank by draining after each use, High humidity environments wiii cause excessive condensation, Utilize water filters on your air line,

NOTE:

Air leaks from the tank body or tank welds,

Water condensation is not caused by compressor malfunction, Be sure the compressor's air output is greater than your tool's air consumption rate,

Never drill into, weld or otherwise modify the air tank or it will weaken, The tank can rupture or explode, Compressor cannot be repaired, Discontinue use of the air compressor,

Image 9
Contents Mode No Contents Mmportant Safety mnstructions and Guidelines Safety SymbolsRisk Burns Risk FallingSpecifications Duty CycleGlossary Parts & Features Grounding instructions Mnsta ation & AssemblyOperating Procedures Storage Ing unit from dollyTroubleshooting Guide Air Compressor Mode Parts List Parts Air Compressor ModeGarantja DE UN ANO Sobre Compresor DE AmRE Craftsman Smbolos comunes de seguridad Lnstrucciones y pautas de seguridad importantesRiesgo de cada Riesgo para a respiraci6n CicJo de trabaoRiesgo de descargas ectricas Riesgo de e×posi6n y fuego Riesgo de estaHidoPartes y caracteristicas Tiempo estimado de ensambJaje aproximadamente 5 minutos Lnstalaci6n y ensamblajeProcedimentos de operaci6n Mantenimiento Para quitar Ja unidad de la carretilJaDiagn6stico y correcci6n de fallas Problema Posible CorreccionYour Home