Cordless Air Compressor
Troubleshooting Chart
Symptom | Possible Cause(s) | Corrective Action | ||
Compressor will not run | 1. | No electrical power to charger | 1. | Plugged in? Check fuse/breaker or motor overload |
| 2. | Blown fuse | 2. | Replace blown fuse |
| 3. | Thermal overload open | 3. | Motor will restart when cool |
| 4. | Charger plugged in | 4. | Remove charger plug from AC adapter jack |
|
|
|
|
| Modelo FP2400 | |
|
|
|
|
| ||
| Tabla de diagnóstico de averías (Cont.) |
|
|
| ||
|
|
| ||||
Síntoma | Causa(s) posible(s) | Acciones a tomar |
| |||
|
| 6. | Motor recalentado | 6. | Si las luces verde o amarilla están encendidas y el tanque | |
|
|
|
|
| está vacío, deje enfriar el motor durante aproximadamente | |
|
| 7. | Otro problema eléctrico |
| 10 minutos. El motor podrá reiniciarse automáticamente. | |
|
|
|
| 7. | Lleve la unidad a un Centro de Servicio Autorizado de | |
|
|
|
|
| Campbell Hausfeld. | |
|
|
|
|
|
|
|
Fuses blow / circuit breaker | Incorrect size fuse, circuit overloaded | Check for proper fuse. | ||
trips |
|
|
|
|
|
|
|
|
|
Thermal overload | 1. | Compressor is being overworked | 1. | Reduce operating time or use a larger compressor |
protector cuts out | 2. | Lack of proper ventilation/room | 2. | Move compressor to well ventilated or cooler area |
repeatedly |
| temperature too high |
|
|
El compresor no se apaga y no alcanza los 140 psi.
1. | Consumo de aire mayor que la salida del | 1. | Reduzca el ciclo de trabajo de la herramienta. |
| compresor |
|
|
2. | Pérdida de aire | 2. | Ajuste todas las conexiones y verifique el drenaje del tanque |
|
|
| en el fondo del compresor. |
3. | Pérdida interna | 3. | Lleve la unidad a un Centro de Servicio Autorizado de |
4. | Bomba defectuosa |
| Campbell Hausfeld. |
|
| 4. | Lleve la unidad a un Centro de Servicio Autorizado de |
|
|
| Campbell Hausfeld. |
Knocks, rattles, excessive | Defective pump | Replace compressor | ||
vibration |
|
|
|
|
|
|
|
|
|
Air output lower than | 1. | Air leaks in piping or hose (on machine or | 1. | Replace leaking components or tighten as necessary |
normal / low discharge |
| in outside system) |
|
|
pressure | 2. | Regulator not set correctly | 2. | Adjust regulator setting |
| 3. | Pump worn | 3. | Replace compressor |
El compresor no se apaga y | 1. Preóstato defectuoso | 1. | Lleve la unidad a un Centro de Servicio Autorizado de | |
supera los 140 psi. |
|
|
| Campbell Hausfeld. |
| 2. | Otro problema eléctrico | 2. | Lleve la unidad a un Centro de Servicio Autorizado de |
|
|
|
| Campbell Hausfeld. |
|
|
|
| |
La batería no carga (las | 1. No hay suministro de CA de 120 voltios al | 1. | Verifique el circuito de alimentación de 120 voltios. | |
luces indicadoras rojas y |
| cargador |
|
|
amarillas no destellan) | 2. El cargador no está enchufado | 2. | Revise la conexión | |
| 3. | Cargador defectuoso | 3. | Reemplace el cargador |
| 4. | Fusible quemado o sin instalar | 4. | Instale o reemplace el fusible |
| 5. | Interruptor de energía apagado | 5. | Encienda el interruptor de energía para que se muestren las |
|
|
|
| luces indicadoras. |
Excessive moisture in | 1. High humidity | 1. | Move to area of less humidity; use air line filter | |||
discharge air | 2. Tank full of water | 2. | Drain tank | |||
|
|
|
| |||
Compressor pump does not | 1. Power off | 1. | Check on/off switch | |||
turn on | 2. Tank contains over 100 psi of air | 2. | Release pressure by using the accessory attached to the | |||
|
|
|
|
| hose. Pressure switch should activate motor when tank | |
|
|
|
|
| pressure drops below the | |
| 3. | Battery | 3. | Allow battery to charge for 14 hours before using | ||
| 4. | Battery charger plugged into compressor | 4. | Unplug charger from compressor. Yellow and red lights will | ||
|
|
|
|
| blink while charging. If charger is not connected to AC but | |
|
|
|
|
| still plugged into compressor, the compressor will not | |
|
|
|
|
| operate. | |
| 5. | Fuse blown | 5. | Open accessory cover and visually check fuse. Replace if | ||
|
|
|
|
| needed. Blown fuse may indicate other problems. | |
|
|
|
|
|
| Do not replace with larger fuse. |
|
|
|
|
| ! WARNING | |
| 6. | Motor overheated | 6. | If green or yellow light is on and tank is empty, allow the | ||
|
|
|
|
| motor to cool for approximately 10 minutes. Motor may | |
|
|
|
|
| restart automatically. | |
| 7. | Other electrical problem | 7. | Take unit to authorized Campbell Hausfeld Service Center. |
(CONTINUED ON NEXT PAGE)
www.chpower.com
La batería no carga (las luces rojas y amarillas destellan)
El aire no llega al accesorio/ herramienta
1. | Fusible quemado | 1. | Revise el fusible dentro de la tapa de accesorios. |
2. | Batería defectuosa | 2. | Lleve la unidad a un Centro de Servicio Autorizado de |
|
|
| Campbell Hausfeld. |
3. | Otro problema eléctrico | 3. | Lleve la unidad a un Centro de Servicio Autorizado de |
|
|
| Campbell Hausfeld. |
1. | Regulador apagado | 1. | Abra el regulador girándolo en sentido horario |
2. | Manguera doblada | 2. | Revise la manguera y enderécela donde fuera necesario |
3. | Accesorio o herramienta neumática | 3. | Revise el accesorio o la herramienta neumática Repárela o |
| defectuosos |
| reemplácela si fuera necesario. |
6 | 27 Sp |