Associated Equipment 6080A important safety instructions Mounting, Controls, Series Charging

Page 3

to a two-pole receptacle, as shown in sketch B, until a properly grounded outlet can be installed by a qualified electrician.

DANGER. Before using adapter as illustrated, be certain that center screw of outlet plate is grounded. The green-colored rigid ear of lug extending from adapter must be connected to a properly grounded outlet, make certain it is grounded. If necessary, replace original outlet cover plate screw with a longer screw that will secure adapter ear lug to outlet cover plate and make ground connection to grounded outlet.

MOUNTING:

The Battery Charger may be set on a table or a shelf. Do not set charger on floor. It should be mounted such that the air intake louvers are at least 18 inches from the floor. Regardless of how it is placed, the top and side louvers of the unit must not be blocked. This is a convection cooled charger and blocking the louvers will damage the unit. When locating the unit, take into account the number of batteries to be recharged and location of the recharging racks. Never place the charger such that battery acid or water may be spilled in the top of the unit. Never place the unit directly over the batteries to be charged. Fumes caused by gassing batteries will be drawn through the charger by convection and cause damage to the unit.

CONTROLS:

AMMETER: Indicates the amount of current that the batteries are receiving. The larger the amount of current, the faster the batteries will charge. All batteries in a series group will receive the same amount of current. Do not exceed 6 amps charge rate.

MAIN POWER SWITCH: This switch turns the power off to the entire charging unit. Any time the charger is not being used, this switch should be turned off to conserve energy.

CHARGE RATE SWITCH: These switches may be used to adjust the charging current the batteries will receive. An off position on these switches will disconnect power from the clamps. One of these switches or the main power switch should be off whenever handling the output clamps.

If the charger is not going to be used for a period of time, turn the main power switch off to conserve energy. Turning off only a charge rate switch will not have the same effect.

CAUTION ! ! !

When a number of batteries are connected in series, a high DC voltage exists at the terminals of the end batteries. When not connected, the charger DC leads will have no output voltage but the battery terminal may still present a shock hazard.

SERIES CHARGING:

Connecting batteries in series (see illustration) allows a person to charge a number of batteries at one time using only one low current, high voltage charger. The amount of charge that each battery receives is indicated by the ammeter. Thus, each battery will arrive in a fully charged condition at a different time. Conditions that affect charging time are battery temperature, size, state of charge, type of battery, and other factors.

Six and twelve volt batteries may be intermixed when series charging. The total voltage of the batteries should not exceed the rated voltage of the charger.

Example: A Charger is rated a nominal 36 cells. Six 12 volt batteries in series or twelve 6 volt batteries in series can be charged or any combination of six and twelve volt batteries that total 36 cells.

To charge batteries in series, connect the charger's positive lead to the positive post of the first battery. Connect a jumper from the negative post of the first battery to the positive post of the next battery. Continue until all batteries are connected. Attach negative lead of charger to remaining battery post.

Dark area represents state of charge of battery.

At start of charge

3

Image 3
Contents Introduction Personal PrecautionsCharger Location DC Connection PrecautionsGrounding and AC Power Cord Connection Instructions Preparing to ChargeMounting ControlsSeries Charging END of Charge Wiring Diagram Model 6080A Parts ListIllustration Listing

6080A specifications

The Associated Equipment 6080A is a versatile piece of machinery known for its robust design and remarkable functionality in various industrial applications. This model is integral in enhancing productivity and efficiency across multiple working environments, particularly in construction, landscaping, and manufacturing sectors.

One of the standout features of the 6080A is its powerful engine, which provides impressive torque and horsepower. This engine is engineered for optimal performance, capable of handling heavy loads and challenging tasks with ease. The durability of the engine is complemented by a high-quality transmission system, ensuring smooth operation and reliable gear shifts, which contribute to the machine's overall efficiency.

The 6080A is designed with user comfort and safety in mind. It incorporates an ergonomic cabin that is spacious and equipped with advanced control systems, allowing operators to navigate and control the equipment with minimal strain. Furthermore, the cabin features enhanced visibility, ensuring that the operator has a clear line of sight to the work area, which is crucial for safe operation.

In terms of technological advancements, the Associated Equipment 6080A integrates state-of-the-art hydraulic systems that enhance its lifting capabilities and maneuverability. This hydraulic system facilitates quick and responsive actions, making it an invaluable tool for tasks requiring precision and speed. Additionally, the machine is equipped with various attachments that can be easily interchanged, increasing its versatility for diverse applications such as digging, lifting, and material handling.

Another important characteristic of the 6080A is its fuel efficiency, which helps reduce operational costs while minimizing environmental impact. Its design incorporates systems that maximize fuel usage, making it a more sustainable choice for businesses looking to lower their carbon footprint.

Maintenance is also a key consideration in the design of the 6080A. It features accessible service points, making routine inspections and upkeep straightforward. This accessibility not only prolongs the lifespan of the machine but also ensures that it operates at peak performance consistently.

Overall, the Associated Equipment 6080A stands out due to its combination of power, versatility, and user-friendly features. Its advanced technologies, robust build quality, and design innovations make it a reliable choice for professionals across various industries, providing excellent value and performance in demanding environments.