EXTENSION CORD LENGTH | WIRE SIZE (AWG) |
|
|
Up to 25 Feet | 14 |
|
|
26 to 50 Feet | 12 |
|
|
51 to 100 Feet | Do Not Use |
|
|
Use only extension cords that are intended for outdoor use. These cords are identi- fied by a marking “ACCEPTABLE FOR USE WITH OUTDOOR APPLIANCES, STORE INDOORS WHEN NOT IN USE.” Examine extension cord before use. DO NOT USE DAMAGED EXTENSION CORDS. Do not pull on cord to disconnect from receptacle; always disconnect by pulling on plug. Keep cord away from heat and sharp edges. Always shut OFF the air compressor AUTO/ON pressure switch before unplugging the compressor. Always disconnect the extension cord from the receptacle before disconnecting the product from the extension cord.
Avoid electrical shock hazard. Never use this compres- sor with a damaged or frayed electrical cord or extension cord. Inspect all electrical cords regularly. Never use in or near water or in any environment where electric shock is possible. To reduce the risk of electrocution, keep all connections dry and off the ground. Do not touch the plug with wet hands.
Guard against electrical shock. Avoid body contact with grounded services such as pipes, ovens, stoves, and refrigerator enclosures. If not properly grounded, this air compressor can incur the potential hazard of light trickle shock, particularly when used in damp locations. If electrical shock occurs, there is the potential of second- ary hazard such as your hands contacting an operating air tool.
COMPRESSOR FEATURES
10
9
1
2 3
4
5 6
7
11
12
8
5
CONTROLS AND COMPONENTS:
1.Automatic On/Off Pressure Switch
2.Air Tank Pressure Gauge
3.Outlet Pressure Gauge
4.Air Coupler
5. Pressure Regulator
6.Safety Relief Valve
7.Air Tank Drain Valve
8.Manual Thermal Overload Switch
9.Air Intake Filter
10.Carry Handle
11.Power Cord
12.Frame and Air tank