MAINTENANCE CHECKLIST:
Daily:
•Drain accumulated liquid from tank.
•Check for unusual noise and/or vibrations.
•Check that all fasteners are secure.
•Wipe compressor clean.
CHECKING SAFETY RELIEF VALVE:
Weekly:
• Inspect and clean air filter.
Monthly:
•Check for air leaks.+
•Check safety relief valve.
TROUBLESHOOTING GUIDE
THE COMPRESSOR DOES NOT START OR RESTART:
PROBABLE CAUSE: | SOLUTION: |
Power cord not plugged in. | Plug cord into grounded outlet. |
Motor/Pressure switch in | Move switch to AUTO position. |
OFF position |
|
Motor thermal overload | Turn air compressor off, wait until the |
switch has tripped | motor is cool, then press motor thermal |
| overload (red) button firmly until click is |
Safety RELIEF valve must be replaced if it cannot be actuated or it leaks air after the ring is released.
1.The air compressor must be turned OFF.
2.Disconnect compressor from the power source.
3.Open tank drain to bleed off all air pressure before attempting any maintenance or repair.
4.Allow compressor to fully cool before attempting any maintenance or repair.
5.Grasp the wire ring on the safety relief valve.
6.Pull and release the ring a few times to ensure that the plunger moves in and out. Replace the safety relief valve if plunger does not move or is difficult to move.
CHECKING AIR FILTER ELEMENT:
1.The air compressor must be turned OFF.
2.Disconnect compressor from the power source.
3.Open tank drain to bleed off all air pressure before attempting any maintenance or repair.
4.Allow compressor to fully cool before attempting any maintenance or repair.
5.Remove the face of the filter body to access the filter element by removing screw holding filter in place.
6.Use compressed air to blow loose dirt and debris from the paper filter element. Replace filter element if it cannot be cleaned sufficiently.
7.Reinsert filter element into filter body and reinstall filter faceplate.
MOISTURE IN COMPRESSED AIR
Moisture is a normal
| heard. |
Fuse blown or circuit | Replace fuse or reset circuit breaker. |
breaker has tripped. | Check for proper fuse amperage. |
| Check for low voltage conditions. |
| Disconnect any other electrical appliances |
| from circuit or operate air compressor on its |
| own branch circuit. |
Wrong gauge wire or length | Check chart in instruction manual for proper |
of extension cord. | gauge wire and cord length. |
Air tank pressure exceeds | Motor will start automatically when air tank |
motor/pressure switch | pressure drops below |
motor/pressure switch. | |
Pressure release valve on | Bleed the line by moving the switch to the OFF |
motor/pressure switch has | position. |
not unloaded pump head |
|
pressure. |
|
Defective motor, motor | Contact Consumer Helpline at |
capacitor, motor/pressure |
|
switch. |
|
WHEN IN THE START / STOP OPTION, MOTOR RUNS CONTINUOUSLY: | |
|
|
PROBABLE CAUSE: | SOLUTION: |
Motor/Pressure switch does | Move the motor/pressure switch to the OFF |
not shut off motor when air | position. If the motor does not shut off, |
compressor reaches | unplug the air compressor. If the electrical |
pressure and safety relief | contacts are welded together, replace the |
valve activates | pressure switch. |
Air compressor is incorrectly | Limit the air pressure to the capacity of the air |
sized. | compressor. Either use a smaller tool or a |
| larger air compressor. |
| 18 |