Kawasaki 840700 instruction manual Troubleshooting Guide, Probable Cause Solution

Page 10

MAINTENANCE CHECKLIST:

Daily:

Drain accumulated liquid from tank.

Check for unusual noise and/or vibrations.

Check that all fasteners are secure.

Wipe compressor clean.

CHECKING SAFETY RELIEF VALVE:

Weekly:

• Inspect and clean air filter.

Monthly:

Check for air leaks.+

Check safety relief valve.

TROUBLESHOOTING GUIDE

THE COMPRESSOR DOES NOT START OR RESTART:

PROBABLE CAUSE:

SOLUTION:

Power cord not plugged in.

Plug cord into grounded outlet.

Motor/Pressure switch in

Move switch to AUTO position.

OFF position

 

Motor thermal overload

Turn air compressor off, wait until the

switch has tripped

motor is cool, then press motor thermal

 

overload (red) button firmly until click is

Safety RELIEF valve must be replaced if it cannot be actuated or it leaks air after the ring is released.

1.The air compressor must be turned OFF.

2.Disconnect compressor from the power source.

3.Open tank drain to bleed off all air pressure before attempting any maintenance or repair.

4.Allow compressor to fully cool before attempting any maintenance or repair.

5.Grasp the wire ring on the safety relief valve.

6.Pull and release the ring a few times to ensure that the plunger moves in and out. Replace the safety relief valve if plunger does not move or is difficult to move.

CHECKING AIR FILTER ELEMENT:

1.The air compressor must be turned OFF.

2.Disconnect compressor from the power source.

3.Open tank drain to bleed off all air pressure before attempting any maintenance or repair.

4.Allow compressor to fully cool before attempting any maintenance or repair.

5.Remove the face of the filter body to access the filter element by removing screw holding filter in place.

6.Use compressed air to blow loose dirt and debris from the paper filter element. Replace filter element if it cannot be cleaned sufficiently.

7.Reinsert filter element into filter body and reinstall filter faceplate.

MOISTURE IN COMPRESSED AIR

Moisture is a normal by-product of compressing air. As the moisture builds during compressor use, it can be carried though the air hose. When using paint spray gun or sandblasting gun, the use of a special filter to remove moisture from the air line is highly recommended. Moisture in the compressed air will cause water spots in paint jobs and cause blasting media to clog the sandblasting gun.

 

heard.

Fuse blown or circuit

Replace fuse or reset circuit breaker.

breaker has tripped.

Check for proper fuse amperage.

 

Check for low voltage conditions.

 

Disconnect any other electrical appliances

 

from circuit or operate air compressor on its

 

own branch circuit.

Wrong gauge wire or length

Check chart in instruction manual for proper

of extension cord.

gauge wire and cord length.

Air tank pressure exceeds

Motor will start automatically when air tank

motor/pressure switch

pressure drops below "cut-in" pressure of

"cut-in" pressure.

motor/pressure switch.

Pressure release valve on

Bleed the line by moving the switch to the OFF

motor/pressure switch has

position.

not unloaded pump head

 

pressure.

 

Defective motor, motor

Contact Consumer Helpline at 1-800-590-3723

capacitor, motor/pressure

 

switch.

 

WHEN IN THE START / STOP OPTION, MOTOR RUNS CONTINUOUSLY:

 

 

PROBABLE CAUSE:

SOLUTION:

Motor/Pressure switch does

Move the motor/pressure switch to the OFF

not shut off motor when air

position. If the motor does not shut off,

compressor reaches "cut-out"

unplug the air compressor. If the electrical

pressure and safety relief

contacts are welded together, replace the

valve activates

pressure switch.

Air compressor is incorrectly

Limit the air pressure to the capacity of the air

sized.

compressor. Either use a smaller tool or a

 

larger air compressor.

 

18

Image 10
Contents Gallon AIR Compressor 2 Peak HP Safety Alert Table of ContentsSpecifications CongratulationsRead ALL Safety Warnings Before Using AIR Compressor Recognize Safety SYMBOLS, Words and LabelsSafety Warnings General Safety WarningsDrain Liquid from AIR Tank Daily ING Vapors and DUST. Wash Hands After UsingAfter Handling Risk of Fire or ExplosionInstallation and Location Grounding Instructions Extension CordsExtension Cord Length Compressor FeaturesControls and Components Initial Setup / BREAK-IN Procedure Compressor FeaturesOperating the AIR Compressor Startup Maintenance and CleaningWhen Performing ANY Maintenance or Service Shutdown and StorageTroubleshooting Guide Probable Cause SolutionAIR Leaks AT Fittings AIR Leaks from Safety Relief ValveInsufficient Pressure AT AIR Tool or AIR Accessory AIR Leaks in AIR TankParts List DescriptionParts List Parts Diagram Description QTYYear Limited Warranty Alltrade Tools LLC AIR CompressorsExclusions Warranty DisclaimersLimitations on Warranty Disclaimers Limitation Of Liability