Xantrex Technology SW3000 user service Installation Information, Before You Begin the Installation

Page 17

Installation Information

Before You Begin the Installation

Before beginning your installation:

Read the entire Installation Guide so you can plan the installation from beginning to end.

Read the Xanbus System Installation Guide to plan your network requirements.

Assemble all the tools and materials you require for the installation.

Review the Important Safety Instructions on page iv.

Be aware of all safety and electrical codes which must be met.

ELECTRICAL SHOCK AND FIRE HAZARDS

All wiring should be done by qualified personnel to ensure compliance with all applicable installation codes and regulations.

Disconnect all AC and DC power sources.

Disable and secure all AC and DC disconnect devices and automatic generator starting devices.

Failure to follow these instructions will result in death or serious injury.

Installation Codes

Applicable installation codes vary depending on the specific location and

only.

application of the installation. Some examples are:

 

The U.S. National Electrical Code (NEC)

installers

(RVIA) for installation in RVs.

The Canadian Electrical Code (CEC)

 

Canadian Standards Association (CSA) and RV Industry Association

 

 

 

This guide for use by qualified

975-0546-01-01

3

Image 17
Contents Freedom SW Sine Wave Inverter/Charger Page This guide for use by qualified installers only Statement of Hazard About This GuideRelated Information Electrical Shock Hazard Important Safety InstructionsExplosion Hazard Fire and Burn HazardPrecautions When Working With Batteries Risk of Damage to the INVERTER/CHARGER Precautions When Preparing to ChargeExposure to Chemicals and Gases Hazard Limitations on USE RegulatoryContents Page This guide for use by qualified installers only Page Introduction Materials List Materials ListBefore You Begin the Installation Installation InformationInstallation Codes Electrical Shock and Fire HazardsAbout the Xanbus System Typical Xanbus System DiagramSystem Accessories Xanbus EnabledTwo Key Performance Factors Planning the InstallationSize and Length of DC Cables Mounting Location of the Freedom SWAC, DC, and Network Components PlanningPlanning AC Input AC ComponentsAC Output AC LoadsAC Output Protection AC Input ProtectionGfci Requirements Tested GFCIsDistribution Panels AC WiringAC Output Neutral Bonding Batteries DC ComponentsDC Disconnects and Over-Current Devices DC CablingDC Grounding Heavy Load Materials Installation Tools and MaterialsTools Overview Installing the Inverter/ChargerHeat Hazard Choosing a Location for the Inverter/ChargerFire and Explosion Hazard Battery acid BatterySafe Close toTo mount the inverter/charger Mounting the Inverter/ChargerConsiderations By qualified installers only Approved Mounting Orientation Orientation? FIRE, Electrical SHOCK, and Energy Hazards Connecting the AC Input and AC Output WiresGeneral AC Wiring Considerations To make the AC input connections Connecting AC Input WiresEquipment Damage Damage other equipment Connecting the AC Output WiresTo make the AC output wiring connections Lines for Single DC Connection Precautions Connecting the DC CablesPreparing the Cables To prepare the DC cablesElectrical Shock and Fire Hazard Guidelines for Routing the DC CablesFire Hazard Connecting the DC Cables to the Inverter/ChargerEquipment Damage DUE to Reverse Polarity To connect the DC cablesDC Terminal Covers To connect the chassis ground DC Wiring and DC GroundingMounting Options Connecting the Battery Temperature Sensor BTSTo mount the sensor on the negative battery terminal Mounting to the Negative Battery TerminalConnecting the BTS Cable to BTS Jack To mount the sensor on the battery case Mounting to the Side of the Battery CaseTo connect the Freedom SW 3000 to the Xanbus network Connecting to the NetworkPerforming Checks Prior to Initial Start-Up Testing in Invert Mode Testing Your InstallationTo verify that the Freedom SW 3000 starts charging Testing in Charge Mode and AC Bypass ModeInstallation Complete Inverter/Charger Physical Specifications Battery Bank Sizing Battery InformationCalculating Battery Size Calculate Battery SizeBattery Information Restrictions on Motor Size Battery BanksBattery Bank Sizing Worksheet = Total watt-hours of AC load between charges Parallel Connection Cabling and Hook-up ConfigurationsBatteries Connected in Series Series ConnectionBatteries in Series-Parallel Connections Series-Parallel ConnectionsPage Page Xantrex Technology Inc

SW3000 specifications

Xantrex Technology SW3000 is a versatile and powerful inverter that plays a crucial role in providing reliable electrical power to off-grid and mobile applications. Designed specifically for those who require a dependable power source in remote locations or for recreational vehicles, the SW3000 stands out with its excellent features and innovative technologies.

One of the primary characteristics of the SW3000 is its ability to deliver a continuous output of 3000 watts, making it suitable for a wide range of appliances and tools. The inverter can handle startup loads for inductive devices, such as refrigerators and air conditioners, with ease. This capability ensures that users can operate their essential equipment without the worry of overloading the system.

The SW3000 inverter is equipped with advanced Pure Sine Wave technology, ensuring that the output power is clean and stable. Pure Sine Wave inverters are crucial for sensitive electronics, as they provide a smooth power output that mimics the utility grid. This feature protects your devices from potential damage caused by lower-quality inverter systems.

Additionally, the Xantrex SW3000 offers integrated features such as an automatic transfer switch, which seamlessly transfers power between the inverter and utility power when both are available. This ensures uninterrupted operation and convenience for the user. The inverter also has a user-friendly interface, including LED indicators that provide information on the inverter's status, allowing for easy monitoring.

Another significant aspect of the SW3000 is its robust thermal management. The design includes built-in cooling fans that prevent overheating during heavy use, ensuring the longevity of the unit. The inverter also comes with multiple safety features, such as over-voltage, under-voltage, and over-temperature protection, offering peace of mind.

Furthermore, the SW3000 is engineered for easy installation, including versatile mounting options, making it an excellent choice for various applications, from boats and RVs to cabins and backup power systems. Its durable design enables it to withstand harsh environmental conditions, ensuring reliable performance in diverse settings.

Overall, the Xantrex Technology SW3000 inverter combines power capacity, advanced technology, and user-friendly features, making it a top choice for those seeking reliable power solutions in off-grid and mobile environments.