Xantrex Technology 1800, 1000 Connecting the AC Input Wires, Multiple-strand wire is required

Page 33

FreedomHF_IC_01-Installation.fm Page 15 Monday, December 24, 2007 9:47 AM

Basic Installation Procedures

Step 4: Connecting the AC Input Wires

WARNING: Fire, Shock and Energy hazards

Make sure wiring is disconnected from all electrical sources before handling. All wiring must be done in accordance with local and national electrical wiring codes. Do not connect the output terminals of the Freedom HF to any incoming AC source.

General AC Wiring Considerations

AC Wiring Connectors

Connect AC wires with crimp-on splice connectors.

The amount of insulation you strip off individual wires will be specified by the connector manufacturer and is different for different types of connectors.

AC and DC

Do not mix AC and DC wiring in the same conduit or panel. Where DC

Wiring

and AC wires must cross, make sure they do so at 90° to one another.

Separation

Consult applicable codes for details about DC and AC wiring in close

 

proximity to each other.

AC Wiring

For your reference, the AC Wiring Compartment is shown in Figure 1-5.

Compartment

 

AC Wiring and

You can plug loads (12 A continuous, 15 A maximum) directly into the

GFCIs

GFCI receptacle on the front panel of the Freedom HF. You can also

 

connect the inverter to an existing AC installation and then plug loads into

 

GFCI receptacles connected to that circuit.

 

If you plan to use the Freedom HF with the GFCI installed on the unit,

 

proceed to “Step 6: Connecting the DC Cables” on page 1–24.

 

If you plan to hard wire the Freedom HF AC input and output to an

 

existing AC installation, read this section.

 

AC wiring includes all the wires and connectors between the AC source

 

and the Freedom HF and all wiring between the inverter, the AC panels,

 

circuit breakers, and the GFCIs. The type and size of the wiring varies

 

with the installation and load. For some RV applications, flexible

 

multiple-strand wire is required.

975-0395-01-01

1–15

This guide for use by qualified installers only

Image 33
Contents Freedom HF Page Freedom HF Inverter/Charger Date and Revision Purpose About This GuideScope AudienceConventions Used Related InformationFollowing conventions are used in this guide Important Safety Instructions 975-0395-01-01 975-0395-01-01 Vii Personal Precautions When Working With BatteriesMarine Unit Location Precautions for Using Rechargeable Appliances 975-0395-01-01 Contents Marine Installation Diagram SpecificationsTypical Drip Shield Placement on a Freedom HF Typical Recreational Vehicle and Fleet Vehicle InstallationXiv Tables Recommended Equipment Ground Cable sizeTable A-1 Xvi Freedom HF Inverter/Charger Installation InstallationFreedom HF Inverter/Charger unit Materials ListInstallation Codes Safety InstructionsHigh Level Overview of Installation Steps Installation Tools and MaterialsBasic Installation Procedures To engine Designing the InstallationSystem More information on bonding relay operation700W Disconnect Devices Each system requires a method Rating of the input breaker in the installation and must beHave an appropriate current rating CircuitsMust be rated 75 C minimum. The cables should be terminated 1Required AC Wire Size vs Breaker Rating2Recommended Cable Sizes May limit how far the protection can be from the battery975-0395-01-01 Choosing a Location for the Freedom HF To mount the Freedom HF Mounting the Freedom HFConnecting the Equipment Ground Connecting the AC Input Wires Existing AC installation, read this sectionMultiple-strand wire is required AC Input Connections 5Freedom HF AC Wiring Compartment 975-0395-01-01 Make Model Connecting AC Output to an Existing AC Circuit975-0395-01-01 975-0395-01-01 6AC Wiring Diagram with an Inverter Subpanel 7AC Wiring Diagram without an Inverter Subpanel 8shows the DC end for your reference Connecting the DC CablesTo make the DC connections 975-0395-01-01 To connect the DC ground DC GroundingTo mount the display panel Mounting the Display PanelTo test the Freedom HF in invert mode Testing Your InstallationTo test the Freedom HF in shore power mode Testing in Shore Power ModeTo install the drip shields Drip Shield Installation For Marine Installations11Typical Drip Shield Placement on a Freedom HF Configuration To adjust the battery type setting Setting Battery Types on the Main UnitTo adjust what is being displayed on the screen Adjusting Display, Alarm, and Charging Current SettingsTo adjust the alarm setting To adjust the charging currentBy default the charging current is set to 1Charging Current Guidelines Page Specifications Electrical Specifications Inverter Mode Electrical Specifications Charge Mode System Specifications Environmental SpecificationsPhysical Specifications Regulatory ApprovalsGraph illustrates inverter operation at 25 C Inverter Overload OperationInvert Power Derating vs. Ambient Temperature Table A-1Charging Voltage Charger Output Current vs. AC Input VoltagePage Marine Installation Diagram Marine Installation Figure B-1Typical Marine Installation Page Page Xantrex Technology Inc
Related manuals
Manual 2 pages 17.35 Kb Manual 66 pages 3.22 Kb Manual 88 pages 1023 b

1000, 1800 specifications

Xantrex Technology offers a range of power inverters that cater to both recreational and professional needs, with the Xantrex 1800 and 1000 models being among the most popular in their lineup. These inverters are specially designed to convert DC power from batteries into clean, pure sine wave AC power, making them suitable for running sensitive electronic devices and appliances.

The Xantrex 1800 is a robust inverter that delivers 1800 watts of continuous power and 3600 watts of peak power. This makes it ideal for powering essential appliances like refrigerators, microwaves, and power tools. Its compact design allows for easier installation in various settings such as RVs, boats, and off-grid homes.

On the other hand, the Xantrex 1000 inverter is designed for lower power requirements, offering 1000 watts of continuous power and 2000 watts of peak power. It is perfect for powering small appliances, electronics, and gadgets, making it a great choice for weekend campers and those who require less energy capacity.

Both models feature advanced technologies, including low idle power draw, which ensures that energy is conserved when the inverter is not actively powering devices. They also include overload protection, ensuring the inverter shuts down automatically if the power exceeds its limits, thus preventing damage to the unit or connected devices.

Another hallmark of Xantrex inverters is their user-friendly interface. The LED indicator lights provide clear status updates on the power output and inverter operation, making it easy for users to monitor performance at a glance. Additionally, both models feature various safety protocols, including short circuit and over-temperature protection, to enhance operational safety.

Installation is straightforward, thanks to the provided mounting options and wiring accessories. The units are designed to withstand harsh environments, with durable casings that enhance longevity and resilience.

In summary, the Xantrex 1800 and 1000 models offer reliable power solutions for a variety of applications. Their combination of high-quality sine wave output, advanced safety features, and user-friendly operation makes them a top choice for anyone seeking dependable off-grid power. With Xantrex, users can trust that they are investing in products engineered for performance and durability in an ever-increasing range of power needs.