Xantrex Technology 1000, 1800 manual Mounting the Display Panel, To mount the display panel

Page 46

FreedomHF_IC_01-Installation.fm Page 28 Monday, December 24, 2007 9:47 AM

Step 7: Mounting the Display Panel

The communications cable supplied with the display panel is 25 feet (7.62 meters) long. If you want to replace the cable with one that is shorter, use a high quality, 6-wire telephone extension cable.

Flush mounting the panel on a wall, bulkhead, or panel requires an opening that is approximately 3.25 × 1.25 inches (8.25 × 3.18 cm). About

1.5inches (3.81 cm) of free space is required within the wall to accommodate the depth of the panel. Be sure there is no wiring or other obstructions within the wall before you make an opening.

To mount the display panel:

1.Choose a location that is dry, out of direct sunlight, free from corrosive or explosive fumes, and otherwise appropriate for mounting an electronic device.

2.Tape the mounting template (in the Freedom HF package) to the mounting surface and mark the locations of the mounting holes and the area to be cut away.

3.Pilot-drill the mounting holes and cut out the hole in which the panel will be inserted.

4.Route the communications cable(s) inside the wall and through the opening.

5.Insert one of the cable’s connectors in either jack on the bottom of the panel.

6.Place the panel in the opening and secure it with appropriate fasteners.

7.Route the communications cable to the Freedom HF and insert the connector in the jack located near the battery select dip switch.

Important: Do not route the communications cable in parallel and in conduit with the AC and DC wires. In situations where the cable must cross with the AC and DC wires, make sure they cross at a 90° angle to each other.

1–28

975-0395-01-01

This guide for use by qualified installers only

Image 46
Contents Freedom HF Page Freedom HF Inverter/Charger Date and Revision Scope About This GuidePurpose AudienceRelated Information Conventions UsedFollowing conventions are used in this guide Important Safety Instructions 975-0395-01-01 Personal Precautions When Working With Batteries 975-0395-01-01 ViiMarine Unit Location Precautions for Using Rechargeable Appliances 975-0395-01-01 Contents Specifications Marine Installation DiagramTypical Recreational Vehicle and Fleet Vehicle Installation Typical Drip Shield Placement on a Freedom HFXiv Recommended Equipment Ground Cable size TablesTable A-1 Xvi Installation Freedom HF Inverter/Charger InstallationMaterials List Freedom HF Inverter/Charger unitSafety Instructions Installation CodesInstallation Tools and Materials High Level Overview of Installation StepsBasic Installation Procedures Designing the Installation To engineMore information on bonding relay operation System700W Have an appropriate current rating Rating of the input breaker in the installation and must beDisconnect Devices Each system requires a method Circuits1Required AC Wire Size vs Breaker Rating Must be rated 75 C minimum. The cables should be terminatedMay limit how far the protection can be from the battery 2Recommended Cable Sizes975-0395-01-01 Choosing a Location for the Freedom HF Mounting the Freedom HF To mount the Freedom HFConnecting the Equipment Ground Existing AC installation, read this section Connecting the AC Input WiresMultiple-strand wire is required AC Input Connections 5Freedom HF AC Wiring Compartment 975-0395-01-01 Connecting AC Output to an Existing AC Circuit Make Model975-0395-01-01 975-0395-01-01 6AC Wiring Diagram with an Inverter Subpanel 7AC Wiring Diagram without an Inverter Subpanel Connecting the DC Cables 8shows the DC end for your referenceTo make the DC connections 975-0395-01-01 DC Grounding To connect the DC groundMounting the Display Panel To mount the display panelTesting Your Installation To test the Freedom HF in invert modeTesting in Shore Power Mode To test the Freedom HF in shore power modeDrip Shield Installation For Marine Installations To install the drip shields11Typical Drip Shield Placement on a Freedom HF Configuration Setting Battery Types on the Main Unit To adjust the battery type settingAdjusting Display, Alarm, and Charging Current Settings To adjust what is being displayed on the screenTo adjust the charging current To adjust the alarm settingBy default the charging current is set to 1Charging Current Guidelines Page Specifications Electrical Specifications Inverter Mode Electrical Specifications Charge Mode Physical Specifications Environmental SpecificationsSystem Specifications Regulatory ApprovalsInverter Overload Operation Graph illustrates inverter operation at 25 CInvert Power Derating vs. Ambient Temperature Charger Output Current vs. AC Input Voltage Table A-1Charging VoltagePage Marine Installation Diagram Marine Installation Figure B-1Typical Marine Installation Page Page Xantrex Technology Inc
Related manuals
Manual 2 pages 17.35 Kb Manual 66 pages 3.22 Kb Manual 88 pages 1023 b

1000, 1800 specifications

Xantrex Technology offers a range of power inverters that cater to both recreational and professional needs, with the Xantrex 1800 and 1000 models being among the most popular in their lineup. These inverters are specially designed to convert DC power from batteries into clean, pure sine wave AC power, making them suitable for running sensitive electronic devices and appliances.

The Xantrex 1800 is a robust inverter that delivers 1800 watts of continuous power and 3600 watts of peak power. This makes it ideal for powering essential appliances like refrigerators, microwaves, and power tools. Its compact design allows for easier installation in various settings such as RVs, boats, and off-grid homes.

On the other hand, the Xantrex 1000 inverter is designed for lower power requirements, offering 1000 watts of continuous power and 2000 watts of peak power. It is perfect for powering small appliances, electronics, and gadgets, making it a great choice for weekend campers and those who require less energy capacity.

Both models feature advanced technologies, including low idle power draw, which ensures that energy is conserved when the inverter is not actively powering devices. They also include overload protection, ensuring the inverter shuts down automatically if the power exceeds its limits, thus preventing damage to the unit or connected devices.

Another hallmark of Xantrex inverters is their user-friendly interface. The LED indicator lights provide clear status updates on the power output and inverter operation, making it easy for users to monitor performance at a glance. Additionally, both models feature various safety protocols, including short circuit and over-temperature protection, to enhance operational safety.

Installation is straightforward, thanks to the provided mounting options and wiring accessories. The units are designed to withstand harsh environments, with durable casings that enhance longevity and resilience.

In summary, the Xantrex 1800 and 1000 models offer reliable power solutions for a variety of applications. Their combination of high-quality sine wave output, advanced safety features, and user-friendly operation makes them a top choice for anyone seeking dependable off-grid power. With Xantrex, users can trust that they are investing in products engineered for performance and durability in an ever-increasing range of power needs.