Xantrex Technology 1000 manual Battery Sizing Worksheet

Page 52

Estimating Battery Requirements

This example illustrates how quickly your battery needs can escalate. To reduce the required battery size, you can conserve energy by eliminating or reducing the use of some loads or by re-charging more frequently.

When sizing your battery, resist the temptation to skip the last step of this calculation (multiplying by 2). More capacity is better since you will have more reserve capacity, be better able to handle large loads and surge loads, and your battery won't be discharged as deeply. Battery life is directly dependent on how deeply the battery is discharged. The deeper the discharge, the shorter the battery life.

Battery Sizing Worksheet

Use the following worksheet to calculate your battery needs. To ensure sufficient battery capacity, be generous when estimating the operating time per day for each of the loads you will run.

 

 

 

 

Daily watt-hours needed

 

 

(A) Power

(B) Operating Time

for this appliance

Appliance

 

Consumption (Watts)

per Day (Hours)

(= A x B)

 

 

 

 

 

 

 

 

 

 

 

 

W

hours

Wh

 

 

 

 

 

 

 

W

hours

Wh

 

 

 

 

 

 

 

W

hours

Wh

 

 

 

 

 

 

 

W

hours

Wh

 

 

 

 

 

 

 

W

hours

Wh

 

 

 

 

 

 

 

W

hours

Wh

 

 

 

 

 

 

 

W

hours

Wh

 

 

 

 

 

 

 

W

hours

Wh

 

 

 

 

 

 

 

 

 

 

 

Total daily watt-hours of AC load

Wh

 

 

 

 

 

 

x Number of days between charges

 

 

 

 

 

 

 

 

 

 

 

= Total watt-hours of AC load between charges

Wh

 

 

 

 

 

 

Battery Ah used between charges (divide by 10)

Ah

 

 

 

 

 

 

 

Recommended Battery Bank Size in Ah (multiply by 2)

Ah

 

 

 

 

 

975-0127-01-01

B–5

Image 52
Contents Page XPower Inverter Owner’s GuideDate and Revision About This Guide PurposeScope AudienceConventions Used Related InformationImportant Safety Instructions Explosive gas precautions Precautions When Working With Batteries Precautions for Using Rechargeable Appliances Contents Troubleshooting SpecificationsBattery Types OperationAlternators and Charging Systems Xii Quality Power IntroductionEase of Use Comprehensive ProtectionFeatures Materials ListFeature Description AC PanelDC Panel Negative DC Cabling Terminal always connects to the cablePage Installation Designing Your Installation1Configuration for Normal Loads 2Configuration for Heavy Loads Calculating Battery Requirements Installation CodesChoosing an Effective Charging System Choosing an Appropriate Location Calculating Cable Sizes Calculating Size of DC Input CablesCalculating Size of Chassis Ground Cable Calculating Fuse/Circuit Breaker Size To select the correct fuse type and sizeSafety Instructions Installing the XPowerInstallation Tools and Materials Installation Overview of Installation Steps Mounting the InverterConnecting the Chassis Ground Grounding LocationsConnecting the DC Cables Chassis Ground ScrewInstallation Installing the XPower Page Operation Turning the Inverter On and OffOperating Several Loads at Once Turning the Inverter Off Between ChargesOperating Limits Power OutputInput Voltage High Surge Loads Inverter LoadsTrouble Loads XPower 1000 unit Routine MaintenanceBatteries Page Troubleshooting Buzz in Audio Equipment Common ProblemsTelevision Reception Troubleshooting Reference Troubleshooting ReferenceTroubleshooting Reference Physical Specifications SpecificationsElectrical Performance Mounting Templates Battery Types Battery TypesAutomotive Starting Batteries Battery Size Deep-Cycle BatteriesBattery Reserve Estimating Battery Requirements Battery Sizing ExampleBattery Sizing Worksheet Two Separate Battery Banks Using Multiple BatteriesTwo Batteries Connected In Parallel Battery Tips Following table Alternators and Charging Systems Charging System RequirementsUsing a Standard Vehicle Alternator Using an Alternator ControllerUsing a High-Output Alternator Charging With an Engine AlternatorCharging From AC Power Charging From Alternative Energy SourcesPage Warranty and Return Information WarrantyWA-2 975-0127-01-01 Product DisclaimerExclusions Return Material Authorization Policy Return ProcedureOut of Warranty Service Information About Your System Purchased From Purchase Date
Related manuals
Manual 2 pages 17.35 Kb Manual 88 pages 1023 b Manual 70 pages 43.18 Kb

1000 specifications

Xantrex Technology offers a range of power inverters that cater to both recreational and professional needs, with the Xantrex 1800 and 1000 models being among the most popular in their lineup. These inverters are specially designed to convert DC power from batteries into clean, pure sine wave AC power, making them suitable for running sensitive electronic devices and appliances.

The Xantrex 1800 is a robust inverter that delivers 1800 watts of continuous power and 3600 watts of peak power. This makes it ideal for powering essential appliances like refrigerators, microwaves, and power tools. Its compact design allows for easier installation in various settings such as RVs, boats, and off-grid homes.

On the other hand, the Xantrex 1000 inverter is designed for lower power requirements, offering 1000 watts of continuous power and 2000 watts of peak power. It is perfect for powering small appliances, electronics, and gadgets, making it a great choice for weekend campers and those who require less energy capacity.

Both models feature advanced technologies, including low idle power draw, which ensures that energy is conserved when the inverter is not actively powering devices. They also include overload protection, ensuring the inverter shuts down automatically if the power exceeds its limits, thus preventing damage to the unit or connected devices.

Another hallmark of Xantrex inverters is their user-friendly interface. The LED indicator lights provide clear status updates on the power output and inverter operation, making it easy for users to monitor performance at a glance. Additionally, both models feature various safety protocols, including short circuit and over-temperature protection, to enhance operational safety.

Installation is straightforward, thanks to the provided mounting options and wiring accessories. The units are designed to withstand harsh environments, with durable casings that enhance longevity and resilience.

In summary, the Xantrex 1800 and 1000 models offer reliable power solutions for a variety of applications. Their combination of high-quality sine wave output, advanced safety features, and user-friendly operation makes them a top choice for anyone seeking dependable off-grid power. With Xantrex, users can trust that they are investing in products engineered for performance and durability in an ever-increasing range of power needs.