www.ti.com  | Equipment  | 
1.4Recommended Operating Conditions
Table 2. Recommended Operating Conditions
Symbol | Description | Min | Typ | Max | Unit | 
  | 
  | 
  | 
  | 
  | 
  | 
Vin, J1  | Supply Voltage  | 9.5  | 10.0  | 10.5  | V  | 
  | 
  | 
  | 
  | 
  | 
  | 
Vout, J4  | Battery Voltage   | 4  | 
  | 7.5  | V  | 
  | 
  | 
  | 
  | 
  | 
  | 
Iin  | Supply Current  | 0  | 
  | 0.5  | A  | 
  | 
  | 
  | 
  | 
  | 
  | 
Iout  | Charge Current  | 0  | 
  | 0.5  | A  | 
  | 
  | 
  | 
  | 
  | 
  | 
2 Equipment
2.1Power Supplies
Power Supply #1 (PS#1): Adjustable from 0 to ≥ 10 VDC at ≥ 1A; used for input J1.
Power Supply #2 (PS#2): Adjustable from 0 to ≥ 10 VDC at ≥ 1.5A; used for Battery Load Board.
2.2Loads
Load #1: Battery Load Circuit Board, 
2.3Meters
Three Fluke 75 DMMs (equivalent or better).
3Equipment Setup
The original test setup of HPA691 is shown in Figure 1.
1.Set the PS #1 for 10V, 1A current limit and then turn off supply. Connect PS#1 across J1, J2 (VIN, GND).
2.Connect a voltage meter (VM #1) across J1, J2 (VIN, GND)
3.Set PS#2 to 5.2V and then turn off supply. Connect to the Battery Load Circuit Board (P/S+, 
4.Connect Load #1 (BAT+, 
5.Connect a voltage meter (VM#2) across J4, J5 (VOUT, GND).
6.Connect a voltage meter (VM#3) across sense resistor on Load #1.
7.Verify the jumpers are placed correctly as per, Figure 1.
Figure 1. Original Test Setup for HPA691 (bq24450 EVM)
SLUU464   | bq24450EVM  | 3  | 
Submit Documentation Feedback  | 
  | 
  | 