Installation
InstallationSetup
1.Insert rubber feet of control box through holes in plate (4). Mount control box (2) on the XM frame using plate (4), bolts (7), and nuts (6).
2
7
7
4
6
ti20973a
FIG. 1: Mount Control Box
2.Place bracket (5) on top of the control box (2) and mount to the XM frame using screws (7) and nuts
(6).
6
2
5
7
ti20974a
FIG. 2: Mount Plate
Installing this equipment requires access to parts that may cause electric shock or other serious injury if work is not performed properly. Have a qualified elec- trician connect power and ground to power switch ter- minals; see manual 3A2980 and FIG. 4 on page 6. Be sure your installation complies with all national, state, and local safety and fire codes.
Connect Power Cable Wires
1.Turn off power to junction box (J).
2.Replace the supplied
(C) with cord restraint fitting (8). Thread the three wires of the power cord to the opposite side of the cabinet for connection to the power inlet at the main disconnect (D). See FIG. 3.
3.Secure the service wires to 1L1 and 3L2 using a #2 Phillips or Pozidriv M3,5 Form 2 screwdriver. Tighten to 7
4.Connect the external ground bond wire (Green or Green/Yellow) to the protective earth lug (PE). Secure with a 3/8 or 7/16
C | 1L1 | D |
3L2
3L2 | PE |
| ti19942a |
FIG. 3: Main Disconnect Electrical Connections
NOTICE
Route power cable (3) to avoid interference with moving parts. See FIG. 4.
313258C | 5 |