8.Set transformer wire taps in hose heat control box
(2). See manual 3A2980 to verify tap wire connec- tion.
9.Install adapters (16) in dosing valve blocks and use fittings (14, 15, 17, or 18) to connect heated hose
(1)fluid inlets.
16 | 16 | |
14, | ||
14, | ||
15, | ||
15, | ||
17, | ||
or 18 | 17, |
or 18
WLD
FIG. 5: Dosing Valves
NOTE:
To connect additional hoses see manual 309572.
10. Install fittings (12) in remote XM mix manifold.
12 23
9a
Setup
Connect 24M943 FTS and Power Wires
NOTICE
Do not coil hose tighter than the minimum bend radius of 3 ft (0.9 m). Do not subject hose to exces- sive weight, impact, or other abuse.
1.Carefully extend FTS probe (H) into the hose sec-
tion from the hose heat control. Do not bend or kink probe. Insert probe in major volume resin side on systems which are not 1:1 mix ratio.
2.Connect FTS (9) to fittings (12) on remote XM mix manifold. See FIG. 6.
3.Connect fitting (23) to FTS coupler (9a) and fitting (19 or 20). Connect fittings (21 or 22) to FTS sensor (9c). Connect fluid hoses to FTS (9).
4.Install one connector (D) between wires. Refer to
Connect Heated Hoses in manual 309572 for instructions.
5.Connect hose assembly cable (F) to FTS cable (R). Slide insulator sleeves (S) over connection. Leave slack (G) in cables as stress relief, to prevent cable failure.
|
| To XM Mix Manifold |
| S | 9a |
S | F R |
|
|
| |
G |
|
|
|
| 9c |
|
| H |
|
| D |
To XM sprayer | ti2684d |
WLD
12 9c
21 or 22
FIG. 6: XM Mix Manifold
19 or 20
FIG. 7: 261670 FTS Kit
6.Connect two black power wires from the hose heat control box (2) to heated hose (1). Refer to Connect Fluid Hose in manual 3A2980 for instructions.
7.Connect FTS cable from control box (2) to FTS cable connection of first length of heated hose from XM sprayer. See illustrations on page 9.
313258C | 7 |