SPECIFICATIONS

Model

 

EC10SB(SL)

 

EC12

 

 

 

 

 

Motor

 

Single-Phase, Induction Motor

 

 

 

 

 

 

Power Source

 

 

Single-Phase, 240V AC 50Hz

 

 

 

 

 

 

Input

 

 

2 HP

 

 

(1.5 KW)

 

 

 

 

 

 

 

 

 

 

Current

 

 

9.5 A

 

 

 

 

 

 

Tank Capacity

 

 

4 gal.

 

 

(15.1 ltr)

 

 

 

 

 

 

 

 

 

 

Maximum Pressure

116 PSI

 

125 PSI

(8 bar)

 

(8.6 bar)

 

 

 

 

 

 

 

 

 

 

 

 

at 40 PSI

6.3 CFM

 

5.9 CFM

 

 

(2.8 bar)

(177 ltr/min)

 

(168 ltr/min)

Free Air

 

 

 

 

 

 

at 90 PSI

5.1 CFM

 

4.8 CFM

Delivery

 

 

 

(6.2 bar)

(144 ltr/min)

 

(136 ltr/min)

 

 

 

 

 

 

 

 

 

 

 

at 100 PSI

4.6 CFM

 

4.6 CFM

 

 

(6.9 bar)

(130 ltr/min)

 

(130 ltr/min)

 

 

 

 

 

 

Lubrication

 

Oil-less

 

Oil

 

 

 

 

 

 

ACCESSORY

WARNING:Accessory other than these shown below can lead to malfunction and

resulting injuries.

PRIOR TO OPERATION

1. Power source

Ensure that the power source to be utilized conforms to the power source requirements specified on the product nameplate.

STANDARD ACCESSORY

EC 10SB(SL)

NO ACCESSORIES

EC 12

Dipstick - - - - - - - - - - - - - - 1

APPLICATIONS

Air source of the pneumatic nailer and stapler.

WARNING: Never use compressor for applications other than compressor

for pneumatic nailer and stapler.

2. Power switch

Ensure that the knob of the pressure switch is in the “OFF” position (Fig. 2). If the plug is connected to a receptacle while the knob is in the “ON” position, the compressor will start operating immediately and can cause serious injury.

ON

 

OFF

OFF

 

 

ON

Knob of the pressure switch

 

EC 10SB(SL)

EC 12

Fig. 2

3. Extension cord

When the work area is far away from the power source, use an extension cord of sufficient thickness and rated capacity (refer page 6). The extension cord should be kept as short as practicable.

WARNING: Damaged cord must be replaced or repaired.

— 8 —

Image 8
Contents Model EC 10SB SL EC Meanings of Signal Words Operation and MaintenanceSafety Important InformationKeep Work Area Clean Never Touch Moving PartsAlways Wear Protection Disconnect the CompressorKeep Motor AIR Vent Clean Keep ALL SCREWS, Bolts and Covers Tightly in PlaceOperate Compressor AT the Rated Voltage Do not Modify the CompressorGrounding Instructions Replacement PartsSafety Valve Must Work Properly Extension Cord Minimum Gage for Cord SetsOperation and Maintenance Name of PartsSpecifications AccessoryStandard Accessory Prior to OperationTransport OperationMaintenance ShutdownService and Repairs OIL TypePage EC10SBSL Page EC12 Page Page 312