CONCERTOTM TOILET DIMENSIONS

Dimensions may vary ±3/8-inch (13mm).

TOILET INSTALLATION INSTRUCTIONS

System Requirements:

2 GPM (10.6 lpm) or larger water pump.

1/2-inch (12.7 mm) water line terminating in 1/2-inch MPT fitting (to connect to toilet water supply hose).

4-bolt floor (closet) flange. SeaLand flanges available include 3-inch spigot, socket, MPT, or 45-degree swivel socket.

12 VDC through 7- or 8-amp fuse or circuit breaker. Use 14-gauge stranded copper wire.

IMPORTANT: If replacing an existing gravity-discharge toilet, make sure the center of the existing discharge flange is at least 11-1/4 inches from the back wall, then proceed to Step 5 for proper positioning of water line and electrical wiring.

STEP 1: Carefully unpack the toilet bowl, rear access lid and floor flange adapter. CAUTION: HANDLE THE VIT-

REOUS CHINA TOILET AND ACCESS LID WITH CARE. SET THE LID IN AN AREA WHERE IT CANNOT BE BROKEN. PLACE LID ON TOILET ONLY AFTER TOILET INSTALLATION IS COMPLETE.

STEP 2: Position the china bowl in the space intended. Confirm that adequate clearance is available for using the flush handle and opening the seat and lid.

STEP 3: Mark the floor at the rear corners of the toilet bowl (fig. 1). Measure the distance between the two marks and divide by 2 to find the toilet centerline. Mark the floor at the rear wall for the centerline.

STEP 4: Place a carpenter’s square against the back wall, and draw a center line on the floor at least 14 inches (356 mm) long (fig. 2). Mark the centerline for the floor flange at 11-1/4 inches (286 mm) from the wall (fig. 3).

Fig. 1

Fig. 2

Fig. 3

3

Image 3 Contents
Dometic Corporation Sanitation Systems ConcertoTable of Contents Toilet Model IdentificationOrdering Parts Concertotm Toilet Dimensions Toilet Installation InstructionsSystem Requirements Page Page Page Remote Flush Switch Components Model 3400 Remote Flush Switch InstallationToilet Controls Switch ToiletImportant Information Before Operation Electronic Flush and Forget OperationNormal Automatic Flush Operation Timing ChartService Operating InstructionsManual Flush Operation Proper Cleaning and MaintenanceDescription Part Number Quantity Deodorants and Special TissueWinterizing Spare PartsFlush Handle Components Control Module Remote Flush SwitchBase Assembly Components Flush Mechanism Components12VDC Toilet System Electrical SpecificationsStatus Light No. of Flashes Pause Condition TroubleshootingError Codes Status Light Color FunctionTroubleshooting cont’d Symptom 3. Flush valve will not close Symptom 6. Water will not stay in bowl Series with flush handle Series with remote flush switch Wiring DiagramsMaster Sanitation Distributors Customer ServiceOther Rights MANUFACTURER’S THREE-YEAR and TEN-YEAR Limited WarrantiesExclusions Implied Warranties