WIRING
Your motor is designed for either
WARNING: ELECTRICAL SHOCK HAZARD.
If you have any doubts concerning the wiring of the motor, consult a qualified electrician.
External Wire Gauge Requirements
Wire Size For 115 & 230 Volt Single Phase Circuits
Distance – Motor to Fuse or Meter Box - Feet
Motor | 100 Ft. | 200 Ft. | 300 Ft. | 500 Ft. | ||||
HP | 115V | 230V | 115V | 230V | 115V | 230V | 115V | 230V |
1 | #8 | #10 | #6 | #8 | #4 | #6 | # | #4 |
|
|
|
|
|
|
|
|
|
When wiring the Compressor Duty Motor refer to the wiring diagram below. Note: Electri- cal wiring should only be done by a certified electrician.
Low Volt (115V)
| 1 | Line 1 |
Red | 2 |
|
Brown |
|
|
Black |
|
|
White | 4 | Line 2 |
High Volt (230V)
| 1 | Line 1 |
Red | 2 |
|
White |
|
|
Brown | 3 |
|
Black | 4 | Line 2 |
Rotation is
Black Leads.
When using external wiring connect the Ground wire (Green) up to the green screw. This procedure is very important. Failure to connect the Ground wire properly will result in a severe safety hazard.
Note: No replacement parts are available for the motor.
PLEASE READ THE FOLLOWING CAREFULLY
THE MANUFACTURER AND/OR DISTRIBUTOR HAS PROVIDED THE PARTS DIAGRAM IN THIS MANUAL AS A REFERENCE TOOL ONLY. NEITHER THE MANUFACTURER NOR DISTRIBUTOR MAKES ANY REPRESENTATION OR WARRANTY OF ANY KIND TO THE BUYER THAT HE OR SHE IS QUALIFIED TO MAKE ANY REPAIRS TO THE PRODUCT OR THAT HE OR SHE IS QUALI- FIED TO REPLACE ANY PARTS OF THE PRODUCT. IN FACT, THE MANUFACTURER AND/OR DISTRIBUTOR EXPRESSLY STATES THE ALL REPAIRS AND PARTS REPLACEMENTS SHOULD BE UNDERTAKEN BY CERTIFIED AND LICENSED TECHNICIANS AND NOT BY THE BUYER. THE BUYER ASSUMES ALL RISK AND LIABILITY ARISING OUT OF HIS OR HER REPAIRS TO THE ORIGINAL PRODUCT OR REPLACEMENT PARTS THERETO, OR ARISING OUT OF HIS OR HER INSTALLATION OF REPLACMENT PARTS THERETO.