Consult your air tool’s manual for needed accessories.
Checking the Oil
1.Check the oil level before operation. Fill the Pump Crankcase with premium quality SAE
IMPORTANT: Running the Air Compressor with the incorrect amount of oil will cause damage to the equipment and void the warranty. To prevent damage, do not use with overfilled or low oil. Slowly fill to full line, wait 2 minutes and fill back up to full line. Compressor has small passages that will fill slowly.
Crankcase Cover (31)
| Oil Sight Glass (33) |
OIL LEVEL |
|
overfill |
|
full |
|
low |
|
Figure 5 | Tank (70) |
2.The oil level should be at the center of the “full” level on the oil level sight glass, as shown in Figure 2. Add oil as needed to maintain this level. Do not let the
oil level go below the center dot (LOW as shown above) and do not overfill the oil so that it is above the center dot (OVERFILL as shown above) on the sight glass.
3.To add oil:
a.Remove the Oil Plug.
b.Using a funnel to avoid spills, pour enough oil into the Pump Crankcase to reach the “full” level in the Oil Sight Glass.
c. Replace the Oil Plug.
Cold Weather Operation
Premium quality SAE
4.If uncertain which oil to use for this compressor, please call Harbor Freight Tools customer service at
5.Change the compressor oil after the first hour of use to remove any debris.
WARNING! To prevent serious injury from burns: Do not add or change the oil while the compressor is in operation. Allow the compressor to cool before replacing oil.