SYSTEM START UP

1.Turn on inlet water supply.

2.Turn on electrical power to system.

3.Flush water into system by depressing flush lever until water starts flowing to the vacuum pump, approxi- mately 15 seconds. The vacuum pump will run for approximately 60 to 90 seconds until system reaches operating vacuum level and then will shut off.

PROPER CLEANING

The SeaLand toilet should be cleaned regularly for maximum sanitation and

operational efficiency. You can clean it just as you would a household toilet.Fig. A

Do not use caustic chemicals, such as drain-opening types, as they will damage the seals.

BOWL CLEANING: For stubborn stains, use SeaLand® Bowl and Seal Cleaner (Fig. A). It’s manufactured especially for use with SeaLand toilets. In certain locations where water is hard, a build-up of lime may dull the toilet bowl finish. Restore the shine with this SeaLand cleaner. If you cannot find it in your area, contact SeaLand for your nearest dealer. If the cleaner is not available, you can also use Bar Keepers Friend® cleanser. It is not neces- sary to vigorously scrub with either product. Please follow label instruc- tions.

SEAL CLEANING: After an extended time, mineral deposits from hard water can build up under the edge of the rubber bowl seal, resulting in a slow leakdown of water from the bowl. To prevent this mineral build-up, periodically clean under the bowl seal with SeaLand Bowl and Seal Cleaner (Fig. B).

1.

Shut off water supply.

 

 

 

2.

Apply cleaner onto the seal cleaning tool (supplied with new toilet), open

 

 

 

Fig. B

 

 

the flush ball by pressing on flush lever, and scrub under the seal. Make

 

 

 

 

 

 

 

 

sure to push bristles between bottom of seal and top of flush ball

 

 

 

 

surface to scrub all parts of seal that come into contact with flush ball.

 

 

 

3.Close ball and wait 2-3 minutes.

4.Open flush ball. Use brush and water to rinse away cleanser and loosened deposits.

WINTERIZING

At the end of each season, the SeaLand toilet should be winterized for

storage, by either draining or using potable water-safe antifreeze in the Fig. C system.

To drain:

1.Thoroughly flush system with fresh water.

2.Empty holding tank.

3.Shut off water supply to toilet(s), and remove inlet waterline (Fig. C).

Do not remove brass cap on bottom of valve.

4.Press flush lever until all water is drained from toilet(s).

To use antifreeze:

1.Drain potable water tank.

2.Add freshwater antifreeze to potable water tank.

3.Flush potable water antifreeze and water mixture through toilet(s) and into the waste holding tank. Each installation is different, so amounts may vary. User discretion is required to assure adequate protection.

4.Empty holding tank.

NOTE: Use nontoxic antifreeze designated for potable water systems. (See vehicle owner’s manual.)

CAUTION: Never use automotive-type antifreeze in freshwater systems.

5

Image 5
Contents Dometic Corporation Sanitation Systems VacuflushProduct Features Table of ContentsImportant Information Before Operation Marine Sanitation RegulationsKEY System Components Winterizing Proper CleaningSystem Start UP Spare Parts MaintenanceOn Board Spare Parts Calculation Chart Per System Pedestal and Pedal Cover Installation Vacuflush Maintenance KITOrdering Parts Toilet Model IdentificationDeodorants and Special Tissue Vacuum Tester AccessoriesService TIP Problem Possible Cause Service Instructions Troubleshooting GuideTroubleshooting Guide Troubleshooting Guide Model 1147 Description 1148 Parts ListDescription Model 506+ Model 508+ Model 547+ Model 548+ 506+ 508+ 547+ 548+ Description Model 1006 1008 1047 1048 Description Vacuum Generator LOW-PROFILE Vacuum Generator Vacuum Dimensional Specifications Wiring Diagrams Master Sanitation Distributors Parts DistributorsExclusions MANUFACTURER’S ONE-YEAR Limited Warranty