Dometic 500Plus Series, 1000 Series owner manual Maintenance, Spare Parts

Page 6

MAINTENANCE

Maintenance intervals and normal parts replacement vary widely depending on numerous factors such as: type of vessel, frequency of system use, quality of flushing water, etc. The chart below is intended strictly as a general guideline. Owner discretion and consideration of actual usage must be the first basis for determining proper maintenance levels.

Maintenance Procedure

Part Number

Approximate Maintenance Level

 

 

 

Follow cleaning procedures (page 5).

Monthly

Tighten all clamps, including base clamp ring.*

Annually

Check all wire connections.

Annually

Check & tighten water valve mounting screws.

Annually

Clean filter screen in water valve.

Annually

Check pump and in-line valves.

385310076 (2)

2-3 years or as needed

Check toilet seals.

385316140

3-5 years or as needed

Check vacuum breaker.

385316906

3-5 years or as needed

Check water valve.

385314349

3-5 years or as needed

*See Base Assembly - Page 10.

 

 

SPARE PARTS

To calculate total spare parts required, determine number and type of toilets and pumps.

On Board Spare Parts Calculation Chart: (Per System)

Type of System

Toilet

Toilet

S Pump

M Pump

Toilet

Vacuum

Toilet

Toilet

Vacuum

Low-Profile

 

 

 

 

Seal

Water

Duckbill

Duckbill

Vacuum

Tank

Ring/

Ball/Shaft

Generator

Vacuum

Toilet Series

Pump Series

& Quantity

& Quantity

Kit

Valve

Valve Kit

Valve Kit

Breaker

Vacuum

Clamp

Cartridge

Switch

Generator

 

 

 

 

 

Kit

 

 

 

Switch

Kit

Kit

Kit

Switch Kit

500+

1000

S

M *

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

1

 

1 each

1 each

2 each

 

 

 

 

 

 

 

2

 

2

 

1 each

1 each

2 each

 

1 each

 

 

1 each

 

 

 

1

1

 

1 each

1 each

2 each

 

 

 

 

 

 

 

 

2

2

 

1 each

1 each

2 each

 

1 each

 

 

1 each

 

 

1

 

 

1

1 each

1 each

 

4 each

 

 

 

 

 

 

2

 

 

1

1 each

1 each

 

4 each

1 each

 

 

1 each

 

 

3

 

 

1

1 each

1 each

 

4 each

1 each

1 each

1 each

1 each

1 each

1 each

4

 

 

1

2 each

2 each

 

4 each

2 each

1 each

1 each

1 each

1 each

1 each

5

 

 

1

2 each

2 each

 

4 each

2 each

1 each

1 each

1 each

1 each

1 each

6

 

 

1

2 each

2 each

 

4 each

2 each

2 each

2 each

2 each

2 each

2 each

 

1

 

1

1 each

1 each

 

4 each

 

 

 

 

 

 

 

2

 

1

1 each

1 each

 

4 each

1 each

 

 

1 each

 

 

 

3

 

1

1 each

1 each

 

4 each

1 each

1 each

1 each

1 each

1 each

1 each

 

4

 

1

2 each

2 each

 

4 each

2 each

1 each

1 each

1 each

1 each

1 each

 

5

 

1

2 each

2 each

 

4 each

2 each

1 each

1 each

1 each

1 each

1 each

 

6

 

1

2 each

2 each

 

4 each

2 each

2 each

2 each

2 each

2 each

2 each

Per Vessel: Vacuum Tester – 530002 (1 each) & Owner’s Manual – (1 each)

* M series pump parts information is contained in a separate M-Pump Owner’s Manual.

6

Image 6
Contents Vacuflush Dometic Corporation Sanitation SystemsTable of Contents Product FeaturesMarine Sanitation Regulations Important Information Before OperationKEY System Components Proper Cleaning System Start UPWinterizing Maintenance On Board Spare Parts Calculation Chart Per SystemSpare Parts Ordering Parts Vacuflush Maintenance KITPedestal and Pedal Cover Installation Toilet Model IdentificationDeodorants and Special Tissue Accessories Service TIPVacuum Tester Troubleshooting Guide Problem Possible Cause Service InstructionsTroubleshooting Guide Troubleshooting Guide Parts List DescriptionModel 1147 Description 1148 Model 506+ Model 508+ Model 547+ Model 548+ 506+ 508+ 547+ 548+ Description Model 1006 1008 1047 1048 Description Vacuum Generator LOW-PROFILE Vacuum Generator Vacuum Dimensional Specifications Wiring Diagrams Parts Distributors Master Sanitation DistributorsMANUFACTURER’S ONE-YEAR Limited Warranty Exclusions